839 resultados para Recommendations to practice
Resumo:
Report on the Iowa Department of Revenue for the year ended June 30, 2010
Resumo:
Report on the Iowa Department of Education, Division of Vocational Rehabilitation Services for the year ended June 30, 2010
Resumo:
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
Report on the Iowa Department of Education, Division of Vocational Rehabilitation Services for the year ended June 30, 2011
Resumo:
Introduction: Targeted intrathecal drug infusion to treat moderate to severe chronic pain has become a standard part of treatment algorithms when more conservative options fail. This therapy is well established in the literature, has shown efficacy, and is an important tool for the treatment of both cancer and noncancer pain; however, it has become clear in recent years that intrathecal drug delivery is associated with risks for serious morbidity and mortality. Methods: The Polyanalgesic Consensus Conference is a meeting of experienced implanting physicians who strive to improve care in those receiving implantable devices. Employing data generated through an extensive literature search combined with clinical experience, this work group formulated recommendations regarding awareness, education, and mitigation of the morbidity and mortality associated with intrathecal therapy to establish best practices for targeted intrathecal drug delivery systems. Results: Best practices for improved patient care and outcomes with targeted intrathecal infusion are recommended to minimize the risk of morbidity and mortality. Areas of focus include respiratory depression, infection, granuloma, device-related complications, endocrinopathies, and human error. Specific guidance is given with each of these issues and the general use of the therapy. Conclusions: Targeted intrathecal drug delivery systems are associated with risks for morbidity and mortality that can be devastating. The panel has given guidance to treating physicians and healthcare providers to reduce the incidence of these problems and to improve outcomes when problems occur.
Resumo:
Report on the University of Northern Iowa for the year ended June 30, 2011
Resumo:
Report on the State University of Iowa, Iowa City, Iowa for the year ended June 30, 2011
Resumo:
Report on the Board of Regents for the year ended June 30, 2011
Resumo:
Report on Iowa State University of Science and Technology, Ames, Iowa, for the year ended June 30, 2011
Resumo:
Audit report of the Public Employment Relations Board for the year ended June 30, 2011
Resumo:
Audit report of the Iowa Department of Revenue for the year ended June 30, 2011
Resumo:
Audit report of the Iowa Board of Parole for the year ended June 30, 2011
Resumo:
Report on the Board of Regents for the year ended June 30, 2012
Resumo:
Report on the State University of Iowa, Iowa City, Iowa for the year ended June 30, 2012