226 resultados para Readout


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (~0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis recoje un trabajo experimental centrado en profundizar sobre el conocimiento de los bloques detectores monolíticos como alternativa a los detectores segmentados para tomografía por emisión de positrones (Positron Emission Tomography, PET). El trabajo llevado a cabo incluye el desarrollo, la caracterización, la puesta a punto y la evaluación de prototipos demostradores PET utilizando bloques monolíticos de ortosilicato de lutecio ytrio dopado con cerio (Cerium-Doped Lutetium Yttrium Orthosilicate, LYSO:Ce) usando sensores compatibles con altos campos magnéticos, tanto fotodiodos de avalancha (Avalanche Photodiodes, APDs) como fotomultiplicadores de silicio (Silicon Photomultipliers, SiPMs). Los prototipos implementados con APDs se construyeron para estudiar la viabilidad de un prototipo PET de alta sensibilidad previamente simulado, denominado BrainPET. En esta memoria se describe y caracteriza la electrónica frontal integrada utilizada en estos prototipos junto con la electrónica de lectura desarrollada específicamente para los mismos. Se muestran los montajes experimentales para la obtención de las imágenes tomográficas PET y para el entrenamiento de los algoritmos de red neuronal utilizados para la estimación de las posiciones de incidencia de los fotones γ sobre la superficie de los bloques monolíticos. Con el prototipo BrainPET se obtuvieron resultados satisfactorios de resolución energética (13 % FWHM), precisión espacial de los bloques monolíticos (~ 2 mm FWHM) y resolución espacial de la imagen PET de 1,5 - 1,7 mm FWHM. Además se demostró una capacidad resolutiva en la imagen PET de ~ 2 mm al adquirir simultáneamente imágenes de fuentes radiactivas separadas a distancias conocidas. Sin embargo, con este prototipo se detectaron también dos limitaciones importantes. En primer lugar, se constató una falta de flexibilidad a la hora de trabajar con un circuito integrado de aplicación específica (Application Specific Integrated Circuit, ASIC) cuyo diseño electrónico no era propio sino comercial, unido al elevado coste que requieren las modificaciones del diseño de un ASIC con tales características. Por otra parte, la caracterización final de la electrónica integrada del BrainPET mostró una resolución temporal con amplio margen de mejora (~ 13 ns FWHM). Tomando en cuenta estas limitaciones obtenidas con los prototipos BrainPET, junto con la evolución tecnológica hacia matrices de SiPM, el conocimiento adquirido con los bloques monolíticos se trasladó a la nueva tecnología de sensores disponible, los SiPMs. A su vez se inició una nueva estrategia para la electrónica frontal, con el ASIC FlexToT, un ASIC de diseño propio basado en un esquema de medida del tiempo sobre umbral (Time over Threshold, ToT), en donde la duración del pulso de salida es proporcional a la energía depositada. Una de las características más interesantes de este esquema es la posibilidad de manejar directamente señales de pulsos digitales, en lugar de procesar la amplitud de las señales analógicas. Con esta arquitectura electrónica se sustituyen los conversores analógicos digitales (Analog to Digital Converter, ADCs) por conversores de tiempo digitales (Time to Digital Converter, TDCs), pudiendo implementar éstos de forma sencilla en matrices de puertas programmable ‘in situ’ (Field Programmable Gate Array, FPGA), reduciendo con ello el consumo y la complejidad del diseño. Se construyó un nuevo prototipo demostrador FlexToT para validar dicho ASIC para bloques monolíticos o segmentados. Se ha llevado a cabo el diseño y caracterización de la electrónica frontal necesaria para la lectura del ASIC FlexToT, evaluando su linealidad y rango dinámico, el comportamiento frente a ruido así como la no linealidad diferencial obtenida con los TDCs implementados en la FPGA. Además, la electrónica presentada en este trabajo es capaz de trabajar con altas tasas de actividad y de discriminar diferentes centelleadores para aplicaciones phoswich. El ASIC FlexToT proporciona una excelente resolución temporal en coincidencia para los eventos correspondientes con el fotopico de 511 keV (128 ps FWHM), solventando las limitaciones de resolución temporal del prototipo BrainPET. Por otra parte, la resolución energética con bloques monolíticos leidos por ASICs FlexToT proporciona una resolución energética de 15,4 % FWHM a 511 keV. Finalmente, se obtuvieron buenos resultados en la calidad de la imagen PET y en la capacidad resolutiva del demostrador FlexToT, proporcionando resoluciones espaciales en el centro del FoV en torno a 1,4 mm FWHM. ABSTRACT This thesis is focused on the development of experimental activities used to deepen the knowledge of monolithic detector blocks as an alternative to segmented detectors for Positron Emission Tomography (PET). It includes the development, characterization, setting up, running and evaluation of PET demonstrator prototypes with monolithic detector blocks of Cerium-doped Lutetium Yttrium Orthosilicate (LYSO:Ce) using magnetically compatible sensors such as Avalanche Photodiodes (APDs) and Silicon Photomultipliers (SiPMs). The prototypes implemented with APDs were constructed to validate the viability of a high-sensitivity PET prototype that had previously been simulated, denominated BrainPET. This work describes and characterizes the integrated front-end electronics used in these prototypes, as well as the electronic readout system developed especially for them. It shows the experimental set-ups to obtain the tomographic PET images and to train neural networks algorithms used for position estimation of photons impinging on the surface of monolithic blocks. Using the BrainPET prototype, satisfactory energy resolution (13 % FWHM), spatial precision of monolithic blocks (~ 2 mm FWHM) and spatial resolution of the PET image (1.5 – 1.7 mm FWHM) in the center of the Field of View (FoV) were obtained. Moreover, we proved the imaging capabilities of this demonstrator with extended sources, considering the acquisition of two simultaneous sources of 1 mm diameter placed at known distances. However, some important limitations were also detected with the BrainPET prototype. In the first place, it was confirmed that there was a lack of flexibility working with an Application Specific Integrated Circuit (ASIC) whose electronic design was not own but commercial, along with the high cost required to modify an ASIC design with such features. Furthermore, the final characterization of the BrainPET ASIC showed a timing resolution with room for improvement (~ 13 ns FWHM). Taking into consideration the limitations obtained with the BrainPET prototype, along with the technological evolution in magnetically compatible devices, the knowledge acquired with the monolithic blocks were transferred to the new technology available, the SiPMs. Moreover, we opted for a new strategy in the front-end electronics, the FlexToT ASIC, an own design ASIC based on a Time over Threshold (ToT) scheme. One of the most interesting features underlying a ToT architecture is the encoding of the analog input signal amplitude information into the duration of the output signals, delivering directly digital pulses. The electronic architecture helps substitute the Analog to Digital Converters (ADCs) for Time to Digital Converters (TDCs), and they are easily implemented in Field Programmable Gate Arrays (FPGA), reducing the consumption and the complexity of the design. A new prototype demonstrator based on SiPMs was implemented to validate the FlexToT ASIC for monolithic or segmented blocks. The design and characterization of the necessary front-end electronic to read-out the signals from the ASIC was carried out by evaluating its linearity and dynamic range, its performance with an external noise signal, as well as the differential nonlinearity obtained with the TDCs implemented in the FPGA. Furthermore, the electronic presented in this work is capable of working at high count rates and discriminates different phoswich scintillators. The FlexToT ASIC provides an excellent coincidence time resolution for events that correspond to 511 keV photopeak (128 ps FWHM), resolving the limitations of the poor timing resolution of the BrainPET prototype. Furthermore, the energy resolution with monolithic blocks read by FlexToT ASICs provides an energy resolution of 15.4 % FWHM at 511 keV. Finally, good results were obtained in the quality of the PET image and the resolving power of the FlexToT demonstrator, providing spatial resolutions in the centre of the FoV at about 1.4 mm FWHM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El diagnóstico y detección temprana de enfermedades son clave para reducir la tasa de mortalidad, las hospitalizaciones de larga duración y el desaprovechamiento de recursos. En los últimos años se ha impulsado, mediante un aumento de la financiación, el desarrollo de nuevos biosensores de bajo coste capaces de detectar y cuantificar cantidades muy pequeñas de especies biológicas de una forma barata y sencilla. El trabajo presentado en esta Tesis Doctoral describe la investigación llevada a cabo en el desarrollo de sensores gravimétricos basados en resonadores de ondas acústicas de volumen (BAW) de estructura maciza (SMR). Los dispositivos emplean películas delgadas de A1N como material piezoeléctrico y operan en modo de cizalladura, para así poder detectar especies biológicas en medio líquido. El principio de funcionamiento de estos sensores se basa en la variación que experimenta la frecuencia de resonancia al quedar una pequeña masa adherida a su superficie. Necesitan operar en modo de cizalladura para que su resonancia no se atenúe al trabajar en medio líquido, así como ofrecer una superficie capaz de ser funcionalizada específicamente para la especie biológica a detectar. El reto planteado en esta tesis requiere un acercamiento pluridisciplinar al problema que incluye el estudio de los diferentes materiales que constituyen la estructura multicapa que forma un SMR, el diseño y fabricación del dispositivo y del sistema de fluídica, la funcionalización bioquímica de la superficie del sensor, la demostración de la capacidad de detección de especies biológicas y finalmente el diseño y fabricación de la electrónica asociada para la detección de la señal eléctrica. Todas esas tareas han sido abordadas en las distintas etapas del desarrollo de esta tesis y las contribuciones más relevantes se describen en el documento. En el campo de desarrollo de los materiales, se propone un proceso en dos etapas para la pulverización reactiva de capas de A1N que contengan microcristales inclinados capaces de excitar el modo de cizalladura. Se caracteriza la velocidad acústica del modo de cizalladura en todos los materiales que componen la estructura, con el fin de poder obtener un diseño más adecuado del reflector acústico. Se propone un nuevo tipo de material aislante de alta impedancia acústica consistente en capas de W03 pulverizadas que presenta ciertas ventajas tecnológicas frente a las capas convencionales de Ta205. Respecto del diseño del transductor, se estudia la influencia que tienen los con tactos eléctricos extendidos del resonador necesarios para poder adaptar el sistema de fluídica a la estructura. Los resultados indican que es necesario trabajar sobre sustratos aislantes (tanto el soporte como el espejo acústico) para evitar efectos parásitos asociados al uso de capas metálicas bajo los electrodos del resonador que dañan su resonancia. Se analiza la influencia de las diferentes capas del dispositivo en el coeficiente de temperatura de la frecuencia (TCF) del resonador llegando a la conclusión de que las dos últimas capas del reflector acústico afectan significativamente al TCF del SMR, pudiendo reducirse ajusfando adecuadamente sus espesores. De acuerdo con los resultados de estos estudios, se han diseñado finalmente resonadores SMR operando a f .3 GHz en modo de cizalladura, con un área activa de 65000 /xm2, contactos eléctricos que se extienden f .7 mm y factores de calidad en líquido de f 50. Las extensiones eléctricas permiten adaptar el resonador a un sistema de fluídica de metacrilato. Para la detección de especies biológicas se realiza un montaje experimental que permite circular 800 ¡A por la superficie del sensor a través de un circuito cerrado que trabaja a volumen constante. La circulación de soluciones iónicas sobre el sensor descubierto pone de manifiesto que las altas frecuencias de operación previenen los cortocircuitos y por tanto el aislamiento de los electrodos es prescindible. Se desarrolla un protocolo ad-hoc de funcionalización basado en el proceso estándar APTESGlutaraldehído. Se proponen dos alternativas novedosas para la funcionalización de las áreas activas del sensor basadas en el uso de capas de oxidación de Ir02 y su activación a través de un plasma de oxígeno que no daña al dispositivo. Ambos procesos contribuyen a simplificar notablemente la funcionalización de los sensores gravimétricos. Se utilizan anticuerpos y aptámeros como receptores para detectar trombina, anticuerpo monoclonal IgG de ratón y bacteria sonicadas. Una calibración preliminar del sensor con depósitos de capas finas de Si02 de densidad y espesor conocidos permite obtener una sensibilidad de 1800 kHz/pg-cm2 y un límite de detección of 4.2 pg. Finalmente se propone el prototipo de un circuito electrónico de excitación y lectura de bajo coste diseñado empleando teoría de circuitos de microondas. Aunque su diseño y funcionamiento admite mejoras, constituye la última etapa de un sistema completo de bajo coste para el diagnóstico de especies biológicas basado en resonadores SMR de A1N. ABSTRACT Early diagnosis and detection of diseases are essential for reducing mortality rate and preventing long-term hospitalization and waste of resources. These requirements have boosted the efforts and funding on the research of accurate and reliable means for detection and quantification of biological species, also known as biosensors. The work presented in this thesis describes the development and fabrication of gravimetric biosensors based on piezoelectric AlN bulk acoustic wave (BAW) solidly mounted resonators (SMRs) for detection of biological species in liquid media. These type of devices base their sensing principles in the variation that their resonant frequency suffers when a mass is attached to their surface. They need to operate in the shear mode to maintain a strong resonance in liquid and an adequate functionalisation of their sensing area to guarantee that only the targeted molecules cause the shift. The challenges that need to be overcome to achieve piezoelectric BAW resonators for high sensitivity detection in fluids require a multidisciplinary approach, that include the study of the materials involved, the design of the device and the fluidic system, the biochemical functionalisation of the active area, the experimental proof-of-concept with different target species and the design of an electronic readout circuit. All this tasks have been tackled at different stages of the thesis and the relevant contributions are described in the document. In the field of materials, a two-stage sputtering deposition process has been developed to obtain good-quality AlN films with uniformly tilted grains required to excite the shear mode. The shear acoustic velocities of the materials composing the acoustic reflector have been accurately studied to ensure an optimum design of the reflector stack. WO3 sputtered films have been proposed as high acoustic impedance material for insulating acoustic reflectors. They display several technological advantages for the processing of the resonators. Regarding the design, a study of the influence of the electrical extensions necessary to fit a fluidic system on the performance of the devices has been performed. The results indicate that high resistivity substrates and insulating reflectors are necessary to avoid the hindering of the resonance due to the parasitic effects induced by the extensions. The influence of the different layers of the stack on the resultant TCF of the SMRs has also been investigated. The two layers of the reflector closer to the piezoelectric layer have a significant influence on the TCF, which can be reduced by modifying their thicknesses accordingly. The data provided by these studies has led to the final design of the devices, which operate at 1.3 GHz in the shear mode and display an active area of 65000 /xm2 and electrical extensions of 1.7 mm while keeping a Qahear=150 in liquid. The extensions enable to fit a custom-made fluidic system made of methacrylate. To perform the biosensing experiments, an experimental setup with a liquid closed circuit operating at constant flow has been developed. Buffers of ionic characteristics have been tested on non-isolated devices, revealing that high operation frequencies prevent the risk of short circuit. An ad-hoc functionalisation protocol based on the standard APTES - Glutaraldehyde process has been developed. It includes two new processes that simplify the fabrication of the transducers: the use of IrO2 as oxidation layer and its functionalisation through an O2 plasma treatment that does not damage the resonators. Both antibodies and aptamers are used as receptors. In liquid sensing proof-of-concept experiments with thrombin, IgG mouse monoclonal antibody and sonicated bacteria have been displayed. A preliminary calibration of the devices using SiO2 layers reveals a sensitivity of 1800 kHz/pg-cm2 and a limit of detection of 4.2 pg. Finally, a first prototype of a low-cost electronic readout circuit designed using a standard microwave approach has been developed. Although its performance can be significantly improved, it is an effective first approach to the final stage of a portable low-cost diagnostic system based on shear mode AlN SMRs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interaction between a peptide hormone and extracellular domains of its receptor is a crucial step for initiation of hormone action. We have developed a modification of the yeast two-hybrid system to study this interaction and have used it to characterize the interaction of insulin-like growth factor 1 (IGF-1) with its receptor by using GAL4 transcriptional regulation with a β-galactosidase assay as readout. In this system, IGF-1 and proIGF-1 bound to the cysteine-rich domain, extracellular domain, or entire IGF-1 proreceptor. This interaction was specific. Thus, proinsulin showed no significant interaction with the IGF-1 receptor, while a chimeric proinsulin containing the C-peptide of IGF-1 had an intermediate interaction, consistent with its affinity for the IGF-1 receptor. Over 2000 IGF-1 mutants were generated by PCR and screened for interaction with the color assay. About 40% showed a strong interaction, 20% showed an intermediate interaction, and 40% give little or no signal. Of 50 mutants that were sequenced, several (Leu-5 → His, Glu-9 → Val, Arg-37 → Gly, and Met-59 → Leu) appeared to enhance receptor association, others resulted in weaker receptor interaction (Tyr-31 → Phe and Ile-43 → Phe), and two gave no detectable signal (Leu-14 → Arg and Glu-46 → Ala). Using PCR-based mutagenesis with proinsulin, we also identified a gain of function mutant (proinsulin Leu-17 → Pro) that allowed for a strong IGF-1–receptor interaction. These data demonstrate that the specificity of the interaction between a hormone and its receptor can be characterized with high efficiency in the two-hybrid system and that novel hormone analogues may be found by this method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the design of a parallel algorithm that uses moving fluids in a three-dimensional microfluidic system to solve a nondeterministically polynomial complete problem (the maximal clique problem) in polynomial time. This algorithm relies on (i) parallel fabrication of the microfluidic system, (ii) parallel searching of all potential solutions by using fluid flow, and (iii) parallel optical readout of all solutions. This algorithm was implemented to solve the maximal clique problem for a simple graph with six vertices. The successful implementation of this algorithm to compute solutions for small-size graphs with fluids in microchannels is not useful, per se, but does suggest broader application for microfluidics in computation and control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have cloned a fusion partner of the MLL gene at 11q23 and identified it as the gene encoding the human formin-binding protein 17, FBP17. It maps to chromosome 9q34 centromeric to ABL. The gene fusion results from a complex chromosome rearrangement that was resolved by fluorescence in situ hybridization with various probes on chromosomes 9 and 11 as an ins(11;9)(q23;q34)inv(11)(q13q23). The rearrangement resulted in a 5′-MLL/FBP17-3′ fusion mRNA. We retrovirally transduced murine-myeloid progenitor cells with MLL/FBP17 to test its transforming ability. In contrast to MLL/ENL, MLL/ELL and other MLL-fusion genes, MLL/FBP17 did not give a positive readout in a serial replating assay. Therefore, we assume that additional cooperating genetic abnormalities might be needed to establish a full malignant phenotype. FBP17 consists of a C-terminal Src homology 3 domain and an N-terminal region that is homologous to the cell division cycle protein, cdc15, a regulator of the actin cytoskeleton in Schizosaccharomyces pombe. Both domains are separated by a consensus Rho-binding motif that has been identified in different Rho-interaction partners such as Rhotekin and Rhophilin. We evaluated whether FBP17 and members of the Rho family interact in vivo with a yeast two-hybrid assay. None of the various Rho proteins tested, however, interacted with FBP17. We screened a human kidney library and identified a sorting nexin, SNX2, as a protein interaction partner of FBP17. These data provide a link between the epidermal growth factor receptor pathway and an MLL fusion protein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A precise and rapid method for identifying sites of interaction between proteins was demonstrated; the basis of the method is direct mass spectrometric readout from the complex to determine the specific components of the proteins that interact--a method termed affinity-directed mass spectrometry. The strategy was used to define the region of interaction of a protein growth factor with a monoclonal antibody. A combination of proteolytic digestion and affinity-directed mass spectrometry was used to rapidly determine the approximate location of a continuous binding epitope within the growth factor. The precise boundaries of the binding epitope were determined by affinity-directed mass spectrometric analysis of sets of synthetic peptide ladders that span the approximate binding region. In addition to the mapping of such linear epitopes, affinity-directed mass spectrometry can be applied to the mapping of other types of molecule-molecule contacts, including ligand-receptor and protein-oligonucleotide interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MEGARA (Multi-Espectrografo en GTC de Alta Resolucion para Astronomia) is an optical Integral-Field Unit (IFU) and Multi-Object Spectrograph (MOS) designed for the GTC 10.4 m telescope in La Palma. The MEGARA Control System will provide the capabilities to move the different mechanisms of the instrument, to readout the data from the detector controller and the necessary routines for the Inspector Panels, the MEGARA Observing Preparation Software Suite, the Data Factory and the Sequencer strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ALICE is one of four major experiments of particle accelerator LHC installed in the European laboratory CERN. The management committee of the LHC accelerator has just approved a program update for this experiment. Among the upgrades planned for the coming years of the ALICE experiment is to improve the resolution and tracking efficiency maintaining the excellent particles identification ability, and to increase the read-out event rate to 100 KHz. In order to achieve this, it is necessary to update the Time Projection Chamber detector (TPC) and Muon tracking (MCH) detector modifying the read-out electronics, which is not suitable for this migration. To overcome this limitation the design, fabrication and experimental test of new ASIC named SAMPA has been proposed . This ASIC will support both positive and negative polarities, with 32 channels per chip and continuous data readout with smaller power consumption than the previous versions. This work aims to design, fabrication and experimental test of a readout front-end in 130nm CMOS technology with configurable polarity (positive/negative), peaking time and sensitivity. The new SAMPA ASIC can be used in both chambers (TPC and MCH). The proposed front-end is composed of a Charge Sensitive Amplifier (CSA) and a Semi-Gaussian shaper. In order to obtain an ASIC integrating 32 channels per chip, the design of the proposed front-end requires small area and low power consumption, but at the same time requires low noise. In this sense, a new Noise and PSRR (Power Supply Rejection Ratio) improvement technique for the CSA design without power and area impact is proposed in this work. The analysis and equations of the proposed circuit are presented which were verified by electrical simulations and experimental test of a produced chip with 5 channels of the designed front-end. The measured equivalent noise charge was <550e for 30mV/fC of sensitivity at a input capacitance of 18.5pF. The total core area of the front-end was 2300?m × 150?m, and the measured total power consumption was 9.1mW per channel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital magnetic recording is based on the storage of a bit of information in the orientation of a magnetic system with two stable ground states. Here we address two fundamental problems that arise when this is done on a quantized spin: quantum spin tunneling and backaction of the readout process. We show that fundamental differences exist between integer and semi-integer spins when it comes to both reading and recording classical information in a quantized spin. Our findings imply fundamental limits to the miniaturization of magnetic bits and are relevant to recent experiments where a spin-polarized scanning tunneling microscope reads and records a classical bit in the spin orientation of a single magnetic atom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les virus ont besoin d’interagir avec des facteurs cellulaires pour se répliquer et se propager dans les cellules d’hôtes. Une étude de l'interactome des protéines du virus d'hépatite C (VHC) par Germain et al. (2014) a permis d'élucider de nouvelles interactions virus-hôte. L'étude a également démontré que la majorité des facteurs de l'hôte n'avaient pas d'effet sur la réplication du virus. Ces travaux suggèrent que la majorité des protéines ont un rôle dans d'autres processus cellulaires tel que la réponse innée antivirale et ciblées pas le virus dans des mécanismes d'évasion immune. Pour tester cette hypothèse, 132 interactant virus-hôtes ont été sélectionnés et évalués par silençage génique dans un criblage d'ARNi sur la production interferon-beta (IFNB1). Nous avons ainsi observé que les réductions de l'expression de 53 interactants virus-hôte modulent la réponse antivirale innée. Une étude dans les termes de gène d'ontologie (GO) démontre un enrichissement de ces protéines au transport nucléocytoplasmique et au complexe du pore nucléaire. De plus, les gènes associés avec ces termes (CSE1L, KPNB1, RAN, TNPO1 et XPO1) ont été caractérisé comme des interactant de la protéine NS3/4A par Germain et al. (2014), et comme des régulateurs positives de la réponse innée antivirale. Comme le VHC se réplique dans le cytoplasme, nous proposons que ces interactions à des protéines associées avec le noyau confèrent un avantage de réplication et bénéficient au virus en interférant avec des processus cellulaire tel que la réponse innée. Cette réponse innée antivirale requiert la translocation nucléaire des facteurs transcriptionnelles IRF3 et NF-κB p65 pour la production des IFNs de type I. Un essai de microscopie a été développé afin d'évaluer l’effet du silençage de 60 gènes exprimant des protéines associés au complexe du pore nucléaire et au transport nucléocytoplasmique sur la translocation d’IRF3 et NF-κB p65 par un criblage ARNi lors d’une cinétique d'infection virale. En conclusion, l’étude démontre qu’il y a plusieurs protéines qui sont impliqués dans le transport de ces facteurs transcriptionnelles pendant une infection virale et peut affecter la production IFNB1 à différents niveaux de la réponse d'immunité antivirale. L'étude aussi suggère que l'effet de ces facteurs de transport sur la réponse innée est peut être un mécanisme d'évasion par des virus comme VHC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We review progress at the Australian Centre for Quantum Computer Technology towards the fabrication and demonstration of spin qubits and charge qubits based on phosphorus donor atoms embedded in intrinsic silicon. Fabrication is being pursued via two complementary pathways: a 'top-down' approach for near-term production of few-qubit demonstration devices and a 'bottom-up' approach for large-scale qubit arrays with sub-nanometre precision. The 'top-down' approach employs a low-energy (keV) ion beam to implant the phosphorus atoms. Single-atom control during implantation is achieved by monitoring on-chip detector electrodes, integrated within the device structure. In contrast, the 'bottom-up' approach uses scanning tunnelling microscope lithography and epitaxial silicon overgrowth to construct devices at an atomic scale. In both cases, surface electrodes control the qubit using voltage pulses, and dual single-electron transistors operating near the quantum limit provide fast read-out with spurious-signal rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid-state quantum computer architectures with qubits encoded using single atoms are now feasible given recent advances in the atomic doping of semiconductors. Here we present a charge qubit consisting of two dopant atoms in a semiconductor crystal, one of which is singly ionized. Surface electrodes control the qubit and a radio-frequency single-electron transistor provides fast readout. The calculated single gate times, of order 50 ps or less, are much shorter than the expected decoherence time. We propose universal one- and two-qubit gate operations for this system and discuss prospects for fabrication and scale up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate a scheme that makes a quantum nondemolition (QND) measurement of the excitation level of a mesoscopic mechanical oscillator by utilizing the anharmonic coupling between two beam bending modes. The nonlinear coupling between the two modes shifts the resonant frequency of the readout oscillator in proportion to the excitation level of the system oscillator. This frequency shift may be detected as a phase shift of the readout oscillation when driven on resonance. We derive an equation for the reduced density matrix of the system oscillator, and use this to study the conditions under which discrete jumps in the excitation level occur. The appearance of jumps in the actual quantity measured is also studied using the method of quantum trajectories. We consider the feasibility of the scheme for experimentally accessible parameters.