958 resultados para Racionamento, PH


Relevância:

20.00% 20.00%

Publicador:

Resumo:

pH monitoring has been used as a diagnostic tool in gastro-oesophageal reflux disease (GERD) for many years. Recent studies have shown that wireless capsule pH monitoring is better tolerated and interferes less with daily activities as compared to traditional catheter-based pH monitoring. Moreover, prolonged recording time (48 h instead of 24 h) is possible with wireless pH monitoring. The main secondary effect of wireless capsule pH monitoring is induction of thoracic discomfort in 10-65% of the patients, which can vary from mild foreign body sensation to severe chest pain. Sensitivity and specificity of wireless capsule monitoring is comparable to that of traditional pH monitoring. It has not been proven yet that better tolerability and a longer recording time increases the diagnostic yield of wireless capsule monitoring in GERD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artículo presenta los primeros resultados del estudio "Identificación de patologías causadas por el PVAc en bienes culturales" que se está realizando en la Sección de Conservación-Restauración de la Facultad de Bellas Artes, Universidad de Barcelona. El trabajo se basa en el estudio de obras originales que fueron tratadas con PVAc en los años 70-80 y pretende identificar los problemas que genera el PVAc en materiales de archivo, arqueológicos, pintura sobre tela, sobre madera y pintura mural. Tras el análisis de las obras originales, se han preparado muestras probeta que reproducen sus características, así como de adhesivos de PVAc comerciales y de uso específico en restauración. Éstas han sido analizadas antes y después de someterlas a dos fases consecutivas de envejecimiento acelerado. También se han analizado obras originales con PVAc aplicado hace aproximadamente 30 años. El artículo presenta los resultados de las mediciones de color y pH en las muestras probeta antes y después de la primera fase de envejecimiento acelerado y, también, en las muestras envejecidas de forma natural durante 10 años.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artículo presenta los primeros resultados del estudio "Identificación de patologías causadas por el PVAc en bienes culturales" que se está realizando en la Sección de Conservación-Restauración de la Facultad de Bellas Artes, Universidad de Barcelona. El trabajo se basa en el estudio de obras originales que fueron tratadas con PVAc en los años 70-80 y pretende identificar los problemas que genera el PVAc en materiales de archivo, arqueológicos, pintura sobre tela, sobre madera y pintura mural. Tras el análisis de las obras originales, se han preparado muestras probeta que reproducen sus características, así como de adhesivos de PVAc comerciales y de uso específico en restauración. Éstas han sido analizadas antes y después de someterlas a dos fases consecutivas de envejecimiento acelerado. También se han analizado obras originales con PVAc aplicado hace aproximadamente 30 años. El artículo presenta los resultados de las mediciones de color y pH en las muestras probeta antes y después de la primera fase de envejecimiento acelerado y, también, en las muestras envejecidas de forma natural durante 10 años.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toxicity and environmental behavior of new pH-sensitive surfactants from lysine are presented. Three different chemical structures are studied: surfactants with one amino acid and one alkyl chain, surfactants with two amino acids on the polar head and one alkyl chain, and gemini surfactants. The pH sensitivity of these compounds can be tuned by modifying their chemical structures. Cytotoxicity has been evaluated using erythrocytes and fibroblast cells. The toxic effects against these cells depend on the hydrophobicity of the molecules as well as their cationic charge density. The effect of hydrophobicity and cationic charge density on toxicity is different for each type of cells. For erythrocytes, the toxicity increases as hydrophobicity and charge density increases. Nevertheless, for fibroblasts cationic charge density affects cytotoxicity in the opposite way: the higher charge density, the lower the toxicity. The effect of the pH on hemolysis has been evaluated in detail. The aquatic toxicity was established using Daphnia magna. All surfactants yielded EC50 values considerably higher than that reported for cationic surfactants based on quaternary ammonium groups. Finally, their biodegradability was evaluated using the CO2 headspace test (ISO 14593). These lysine derivatives showed high levels of biodegradation under aerobic conditions and can be classified as"readily biodegradable compounds".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orosomucoid (ORM) phenotyping has been performed on 329 unrelated Swiss subjects, using immobilized pH gradients with 8 M urea and 2% v/v 2-mercaptoethanol followed by immunoblotting. After desialylation the band patterns of ORM confirmed that the polymorphism of the structural locus ORM1 is controlled by three codominant autosomal alleles (ORM1*F1, ORM1*S and ORM1*F2). One rare and one new allele were detected. The rare variant, tentatively assigned to the second structural locus ORM2, is observed in a cathodal position and named ORM2 B1. The new variant, tentatively assigned to the first structural locus ORM1, is observed in a region located between ORM1 S and ORM1 F2, and named ORM1 F3. Moreover, the pI values of the ORM variants have been measured accurately with Immobiline Dry Plates (LKB): they were found to be within the pH range 4.93-5.14.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(ß,L-malic acid) (PMLA) was made to interact with the cationic anticancer drug Doxorubicin (DOX) in aqueous solution to form ionic complexes with different compositions and an efficiency near to 100%. The PMLA/DOX complexes were characterized by spectroscopy, thermal analysis, and scanning electron microscopy. According to their composition, the PMLA/DOX complexes spontaneously self-assembled into spherical micro or nanoparticles with negative surface charge. Hydrolytic degradation of PMLA/DOX complexes took place by cleavage of the main chain ester bond and simultaneous release of the drug. In vitro drug release studies revealed that DOX delivery from the complexes was favored by acidic pH and high ionic strength

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä työssä Oy Keskuslaboratoriossa sijaitsevalla kiertovesisimulaattorilla on tutkittiu ditioniittivalkaisun ja hylyn määrän vaikutusta pH:n stabiilisuuteen ja häiriöaineiden määrään neutraalissa LWC-prosessissa. Lisäksi on tutkittu ditioniitin määrän seisokkien ja valkaisuviiveiden vaikutusta. Kirjallisuusosassa tutustutaan ditioniittivalkaisuun ja valkaisun kemiaan sekä kalsiumkarbonaatin liukenemiseen. Lyhyesti selvitetään myös paperikoneen vesikiertoja sekä prosessissa olevia häiriöaineita. Karbonaatin liukenemisen osalta tarkastellaan myös mahdollisuutta mallintaa prosessia. Diplomityön aikana ajettiin yhdeksän simulaattoriajoa, jotka ajettiin kahden tai kolmen ajon sarjoissa. Ajoja ajettiin kolmella eri hylkymäärällä. Ditioniittivalkaisun lisäksi suoritettiin referenssiajoja ilman valkaisua. Lyhyen kierron pH pyrittiin pääosin säätämään seitsemään. Valkaisuviiveiden ja yli-yön kestävien seisokkien vaikutusta tutkittiin myös. Kokeissa todettiin ditioniitin alentavan pH tasoa. Tämä pH:n aleneminen johtaa kalsiumkarbonaatin liukenemiseen kalsiumkarbonaatin pyrkiessä puskuroimaan pH:n laskua. Valkaisureaktiossa syntyy negatiivisesti varauruneita yhdisteitä, jotka lisäävät prosessin anionisuutta. Ditioniitin valkaisuvaikutus näkyi lopputuotteen vaaleuden kasvuna sekä kieroveden värillisten yhdisteiden vähenemisenä. Ditioniittivalkaisu näytti poistavan myös noin 30% ligniinistä. Lipofiilisiin uuteaineisiin ditioniitilla ei ollut vaikutusta. Riittävä ditioniittiannos kokeiden perusteella on korkeintaan 1% ditioniittiä käytetyn mekaanisen massan määrästä. Korkeammalla annostuksella ei ollut vaikutusta vaaleuteen. Valkaisuaikana 30 minuuttia on riittävä. Pidempien valkaisuviiveiden ja seisokkien aikana valkaisussa syntyvän sulfiitin todettiin muuttuvan sulfaatiksi. Hylyn määrän lisääminen nosti pH:ta, varausta, johtokykyä ja liuenneen kalsiumin määrään. Hylyn määrän lisäminen paransi myös optisia ominaisuuksia, mikä johtui osin hylyn sisältämästä kalsiumkarbonaatista ja osin hylyn sisältämästä mekaanisesta massasta, joka oli valkaistua.