939 resultados para Pulse Width Modulation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a novel algorithm for compression of single lead Electrocardiogram (ECG) signals. The method is based on Pole-Zero modelling of the Discrete Cosine Transformed (DCT) signal. An extension is proposed to the well known Steiglitz-Hcbride algorithm, to model the higher frequency components of the input signal more accurately. This is achieved by weighting the error function minimized by the algorithm to estimate the model parameters. The data compression achieved by the parametric model is further enhanced by Differential Pulse Code Modulation (DPCM) of the model parameters. The method accomplishes a compression ratio in the range of 1:20 to 1:40, which far exceeds those achieved by most of the current methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nonlinear absorption and refraction characteristics of cesium lithium borate (CsLiB6O10) crystal have been studied using Z-scan technique. Ti:sapphire laser with 110 fs pulse width operating at 800 nm wavelength and pulse repetition rate of 1 kHz is used as the source of photons. Intensity of the laser pulse is varied from 0.541 to 1.283 T W/cm2 to estimate the intensity dependence of multiphoton absorption coefficients. Using the theory of multiphoton absorption proposed by Sutherland [ Handbook of Nonlinear Optics, in 2nd ed., edited by D. G. McLean and S. Kirkpatrick, Dekker, New York (2003) ], found that open aperture Z-scan data fit well for the five-photon absorption (5PA) process. 5PA coefficients are obtained by fitting the expressions into the open aperture experimental data for various peak intensities (I00). The nonlinear refractive index n2 estimated from closed aperture Z-scan experiment is 1.075×10−4 cm2/T W at an input peak intensity of 0.723 T W/cm2. The above experiment when repeated with a 532 nm, 6 ns pulsed laser led to an irreversible damage of the sample resulting in an asymmetric open aperture Z-scan profile. This indicates that it is not possible to observe multiphoton absorption in this regime of pulse width using 532 nm laser.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultrasonic C-Scan is used very often to detect flaws and defects in the composite components resulted during fabrication and damages resulting from service conditions. Evaluation and characterization of defects and damages of composites require experience and good understanding of the material as they are distinctly different in composition and behavior as compared to conventional metallic materials. The failure mechanisms in composite materials are quite complex. They involve the interaction of matrix cracking, fiber matrix interface debonding, fiber pullout, fiber fracture and delamination. Generally all of them occur making the stress and failure analysis very complex. Under low-velocity impact loading delamination is observed to be a major failure mode. In composite materials the ultrasonic waves suffer high acoustic attenuation and scattering effect, thus making data interpretation difficult. However these difficulties can be overcome to a greater extent by proper selection of probe, probe parameter settings like pulse width, pulse amplitude, pulse repetition rate, delay, blanking, gain etc., and data processing which includes image processing done on the image obtained by the C-Scan.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High density transparent glasses (7.86 g/cc) were fabricated in the 2Bi(2)O(3)-B2O3 (BBO) system. Optical band gap of the obtained glasses was found to be 2.6eV. The refractive index measured for these glasses was 2.25 +/- 0.05 at lambda=543 nm. Nonlinear refraction and absorption studies were carried out on the BBO glasses using z-scan technique a lambda=532 nm of 10 ns pulse width. The nonlinear refractive index obtained was n(2)=12.1x10(-14) cm(2)/W and nonlinear absorption coefficient was beta=15.2 cm/GW. The n(2) and beta values of the BBO glasses were large compared to the other reported high index bismuth based oxide glass systems in the literature. These were attributed to the high density, high linear refractive index, low band gap and two photon absorption associated with these glasses. The electronic origin of large nonlinearities was discussed based on bond-orbital theory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a set of metrics that evaluate the uniformity, sharpness, continuity, noise, stroke width variance,pulse width ratio, transient pixels density, entropy and variance of components to quantify the quality of a document image. The measures are intended to be used in any optical character recognition (OCR) engine to a priori estimate the expected performance of the OCR. The suggested measures have been evaluated on many document images, which have different scripts. The quality of a document image is manually annotated by users to create a ground truth. The idea is to correlate the values of the measures with the user annotated data. If the measure calculated matches the annotated description,then the metric is accepted; else it is rejected. In the set of metrics proposed, some of them are accepted and the rest are rejected. We have defined metrics that are easily estimatable. The metrics proposed in this paper are based on the feedback of homely grown OCR engines for Indic (Tamil and Kannada) languages. The metrics are independent of the scripts, and depend only on the quality and age of the paper and the printing. Experiments and results for each proposed metric are discussed. Actual recognition of the printed text is not performed to evaluate the proposed metrics. Sometimes, a document image containing broken characters results in good document image as per the evaluated metrics, which is part of the unsolved challenges. The proposed measures work on gray scale document images and fail to provide reliable information on binarized document image.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Before installation, a voltage source converter is usually subjected to heat-run test to verify its thermal design and performance under load. For heat-run test, the converter needs to be operated at rated voltage and rated current for a substantial length of time. Hence, such tests consume huge amount of energy in case of high-power converters. Also, the capacities of the source and loads available in the research and development (R&D) centre or the production facility could be inadequate to conduct such tests. This paper proposes a method to conduct heat-run tests on high-power, pulse width modulated (PWM) converters with low energy consumption. The experimental set-up consists of the converter under test and another converter (of similar or higher rating), both connected in parallel on the ac side and open on the dc side. Vector-control or synchronous reference frame control is employed to control the converters such that one draws certain amount of reactive power and the other supplies the same; only the system losses are drawn from the mains. The performance of the controller is validated through simulation and experiments. Experimental results, pertaining to heat-run tests on a high-power PWM converter, are presented at power levels of 25 kVA to 150 kVA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photoacoustic/thermoacoustic imaging is an emerging hybrid imaging modality combining optical/microwave imaging with ultrasound imaging. The photoacoustic/thermoacoustic signal generated are affected by the nature of excitation pulse waveform, pulse width, target object size, transducer size etc. In this study k-wave was used to simulate various configurations of excitation pulse, transducer types, and target object sizes and to see their effect on the photoacoustic/thermoacoustic signals. Numerical blood vessel phantom was also used to see the effect of various pulse waveform and excitation pulse width on the reconstructed images. This study will help in optimizing transducer design and reconstruction methods to obtain the superior reconstructed image.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photoacoustic/thermoacoustic tomography is an emerging hybrid imaging modality combining optical/microwave imaging with ultrasound imaging. Here, a k-wave MATLAB toolbox was used to simulate various configurations of excitation pulse shape, width, transducer types, and target object sizes to see their effect on the photoacoustic/thermoacoustic signals. A numerical blood vessel phantom was also used to demonstrate the effect of various excitation pulse waveforms and pulse widths on the reconstructed images. Reconstructed images were blurred due to the broadening of the pressure waves by the excitation pulse width as well as by the limited transducer bandwidth. The blurring increases with increase in pulse width. A deconvolution approach is presented here with Tikhonov regularization to correct the photoacoustic/thermoacoustic signals, which resulted in improved reconstructed images by reducing the blurring effect. It is observed that the reconstructed images remain unaffected by change in pulse widths or pulse shapes, as well as by the limited bandwidth of the ultrasound detectors after the use of the deconvolution technique. (C) 2013 Optical Society of America

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Modern pulse-width-modulated (PWM) rectifiers use LC L filters that can be applied in both the common mode and differential mode to obtain high-performance filtering. Interaction between the passive L and C components in the filter leads to resonance oscillations. These oscillations need to be damped either by the passive damping or active damping. The passive damping increases power loss and can reduce the effectiveness of the filter. Methods of active damping, using control strategy, are lossless while maintaining the effectiveness of the filters. In this paper, an active damping strategy is proposed to damp the oscillations in both line-to-line and line-to-ground. An approach based on pole placement by the state feedback is used to actively damp both the differential-and common-mode filter oscillations. Analytical expressions for the state-feedback controller gains are derived for both continuous and discrete-time model of the filter. Tradeoff in selection of the active damping gain on the lower order power converter harmonics is analyzed using a weighted admittance function. Experimental results on a 10-kVA laboratory prototype PWM rectifier are presented. The results validate the effectiveness of the active damping method, and the tradeoff in the settings of the damping gain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 32.1 W laser-diode-stack pumped acoustic-optic Q-switched Nd:YVO4 slab laser with hybrid resonator at 1064 nm was demonstrated with the pumping power of 112 W and repetition rate of 40 kHz, the pulse duration was 32.47 ns. The slope efficiency and optical-to-optical efficiency were 37 and 28.7%, respectively. At the repetition rate of 20 kHz and pumping power of 90 W, the average output power and pulse duration were 20.4 W and 20.43 ns, respectively. With the pumping power of 112 W, the beam quality M-2 factors in CW operation were measured to be 1.3 in stable direction and 1.6 in unstable direction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dynamics and harmonics emission spectra due to electron oscillation driven by intense laser pulses have been investigated considering a single electron model. The spectral and angular distributions of the harmonics radiation are numerically analyzed and demonstrate significantly different characteristics from those of the low-intensity field case. Higher-order harmonic radiation is possible for a sufficiently intense driving laser pulse. A complex shifting and broadening structure of the spectrum is observed and analyzed for different polarization. For a realistic pulsed photon beam, the spectrum of the radiation is redshifted for backward radiation and blueshifted for forward radiation, and spectral broadening is noticed. This is due to the changes in the longitudinal velocity of the electron during the laser pulse. These effects are much more pronounced at higher laser intensities giving rise to even higher-order harmonics that eventually leads to a continuous spectrum. Numerical simulations have further shown that broadening of the high harmonic radiation can be limited by increasing the laser pulse width. The complex shifting and broadening of the spectra can be employed to characterize the ultrashort and ultraintense laser pulses and to study the ultrafast dynamics of the electrons. (c) 2006 American Institute of Physics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dynamics of the plasma ions in the wake fields of short, ultraintense laser pulses in underdense plasmas are investigated analytically and numerically. Owing to the large ion-to-electron mass ratio, the motion of plasma ions in-such wake fields has often been assumed to be neglectable. It is shown that when the laser intensity exceeds 10(20) W/cm(2), the ion motion can no longer be ignored. In this case, ion momentum peaks appear behind the laser pulse, which correspond with the ion density peaks. The laser-excited wake field appears to be effective for ion acceleration, in particular to ions with high-charge numbers. The dependence of ion acceleration on the laser intensity, pulse width, and background plasma density is discussed. (c) 2006 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

研究了紧聚焦的线偏振飞秒超强高斯激光脉冲俘获并剧烈加速斜入射低能相对论电子的效应,发现被俘获的电子在激光脉冲纵向有质动力的强大加速作用下,可以获得GeV量级的能量,并详细研究了入射电子的初能量、斜入射角、电子与激光脉冲的相对延迟时间和激光脉冲宽度等条件对电子能量增益的影响,发现当激光脉宽超过10λ时,脉宽对电子能量增益影响不大.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

研究了逆流相对论电子与激光脉冲相互作用获得激光同步辐射的频率上移、微分散射截面等特性.发现逆流相对论电子与短脉冲激光相互作用,可以获得阿秒X射线辐射脉冲.短脉冲激光条件下得到的后向散射光的频率上移与长脉冲激光条件下得到的后向散射光的频率上移是完全一致的,同时发现随着入射电子初始能量的增加,散射光的准直性越来越好,后向散射光脉冲的脉宽越来越短.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

利用强激光场电离和离解分子来研究分子激发态的波包结构是强场物理的重要研究方向。利用短时指数传播子对称分割法和快速傅里叶变换技术。数值求解了一维含时Schr(oe)dinger方程,探讨了双色激光场中激光的基波和谐波强度之间的不同配比以及脉宽对线性多原子分子离子电离的影响。理论计算结果表明:基波和谐波的相对相位为π时,尽管随着激光的基波和谐波强度之间配比的变化,电离几率随原子间距变化的趋势基本保持不变,但在一定的激光基波强度下(1.2×10^13~1.2×10^15W/cm^2),激光基波强度的变化可以明显