890 resultados para Power quality mitigations


Relevância:

80.00% 80.00%

Publicador:

Resumo:

High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The goal of the power monitoring in electrical power systems is to promote the reliablility as well as the quality of electrical power.Therefore, this dissertation proposes a new theory of power based on wavelet transform for real-time estimation of RMS voltages and currents, and some power amounts, such as active power, reactive power, apparent power, and power factor. The appropriate estimation the of RMS and power values is important for many applications, such as: design and analysis of power systems, compensation devices for improving power quality, and instruments for energy measuring. Simulation and experimental results obtained through the proposed MaximalOverlap Discrete Wavelet Transform-based method were compared with the IEEE Standard 1459-2010 and the commercial oscilloscope, respectively, presenting equivalent results. The proposed method presented good performance for compact mother wavelet, which is in accordance with real-time applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the progress of devices technology, generation and use of energy ways, power quality parameters start to influence more significantly the various kinds of power consumers. Currently, there are many types of devices that analyze power quality. However, there is a need to create devices, and perform measurements and calculate parameters, find flaws, suggest changes, and to support the management of the installation. In addition, you must ensure that such devices are accessible. To maintain this balance, one magnitude measuring method should be used which does not require great resources processing or memory. The work shows that application of the Goertzel algorithm, compared with the commonly used FFT allows measurements to be made using much less hardware resources, available memory space to implement management functions. The first point of the work is the research of troubles that are more common for low voltage consumers. Then we propose the functional diagram indicate what will be measured, calculated, what problems will be detected and that solutions can be found. Through the Goertzel algorithm simulation using Scilab, is possible to calculate frequency components of a distorted signal with satisfactory results. Finally, the prototype is assembled and tests are carried out by adjusting the parameters necessary for one to maintain a reliable device without increasing its cost.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação (Mestrado)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to the growing concerns associated with fossil fuels, emphasis has been placed on clean and sustainable energy generation. This has resulted in the increase in Photovoltaics (PV) units being integrated into the utility system. The integration of PV units has raised some concerns for utility power systems, including the consequences of failing to detect islanding. Numerous methods for islanding detection have been introduced in literature. They can be categorized into local methods and remote methods. The local methods are categorically divided into passive and active methods. Active methods generally have smaller Non-Detection Zone (NDZ) but the injecting disturbances will slightly degrade the power quality and reliability of the power system. Slip Mode Frequency Shift Islanding Detection Method (SMS IDM) is an active method that uses positive feedback for islanding detection. In this method, the phase angle of the converter is controlled to have a sinusoidal function of the deviation of the Point of Common Coupling (PCC) voltage frequency from the nominal grid frequency. This method has a non-detection zone which means it fails to detect islanding for specific local load conditions. If the SMS IDM employs a different function other than the sinusoidal function for drifting the phase angle of the inverter, its non-detection zone could be smaller. In addition, Advanced Slip Mode Frequency Shift Islanding Detection Method (Advanced SMS IDM), which has been introduced in this thesis, eliminates the non-detection zone of the SMS IDM. In this method the parameters of SMS IDM change based on the local load impedance value. Moreover, the stability of the system is investigated by developing the dynamical equations of the system for two operation modes; grid connected and islanded mode. It is mathematically proven that for some loading conditions the nominal frequency is an unstable point and the operation frequency slides to another stable point, while for other loading conditions the nominal frequency is the only stable point of the system upon islanding occurring. Simulation and experimental results show the accuracy of the proposed methods in detection of islanding and verify the validity of the mathematical analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lappeenrannan teknillinen yliopisto tutkii pientasajännitesähkön käyttöä. Yliopisto on rakennuttanut Järvi-Suomen Energia Oy:n ja Suur-Savon Sähkö Oy:n kanssa yhteistyössä kokeellisen pientasajännitesähköverkon, jolla pystytään tarjoamaan kenttäolosuhteet pienjännitetutkimukselle todellisilla asiakkailla ja todentaa LVDC-teknologiaa ja muita älykkään sähköverkon toimintoja kenttäolosuhteissa. Verkon tasajänniteyhteys on rakennettu 20 kV sähkönjakeluverkon ja neljän kuluttajan välille. 20 kV keskijännite suunnataan tasamuuntamolla ±750 V pientasajännitteeksi ja uudestaan 400/230 V vaihtojännitteeksi kuluttajien läheisyydessä. Tämän kandidaatintyön tarkoituksena on luoda yliopistolle tietokanta pientasajännitesähköverkosta kertyvälle tiedolle ja mittaustuloksille. Tietokanta nähtiin tarpeelliseksi luoda, jotta pienjänniteverkon mittaustuloksia pystytään myöhemmin tarkastelemaan yhdessä ja yhtenäisessä muodossa. Yhdeksi tutkimuskysymykseksi muodostui, kuinka järjestää ja visualisoida kaikki verkosta palvelimille kertyvä mittausdata. Työssä on huomioitu myös kolme tietokantaa mahdollisesti hyödyntävää käyttäjäryhmää: kotitalousasiakkaat, sähköverkkoyhtiöt ja tutkimuslaboratorio, sekä pohdittu tietokannan hyötyä ja merkitystä näille käyttäjille. Toiseksi tutkimuskysymykseksi muodostuikin, mikä kaikesta tietokantaan talletetusta datasta olisi oleellisen tärkeää ottaa talteen näiden asiakkaiden kannalta, ja kuinka nämä voisivat hakea tietoa tietokannasta. Työn tutkimusmenetelmät perustuvat jo valmiiksi olemassa olevaan mittausdataan. Työtä varten on käytetty sekä painettua että sähköisessä muodossa olevaa kirjallisuutta. Työn tuloksena on saatu luotua tietokanta MySQL Workbench -ohjelmistolla, sekä mittausdatan keräys- ja käsittelyohjelmat Python-ohjelmointikielellä. Lisäksi on luotu erillinen MATLAB-rajapinta tiedon visualisoimista varten, jolla havainnollistetaan kolmen asiakasryhmän mittausdataa. Tietokanta ja sen tiedon visualisointi antavat kuluttajalle mahdollisuuden ymmärtää paremmin omaa sähkönkäyttöään, sekä sähköverkkoyhtiöille ja tutkimuslaboratorioille muun muassa tietoa sähkön laadusta ja verkon kuormituksesta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Com este trabalho pretende-se analisar o consumo de energia na indústria de faiança e identificar medidas de poupança energética. Em 2014, o consumo específico foi de 191 kgep/t e a intensidade carbónica 2,15 tCO2e/t, tendo havido uma redução de, respectivamente, 50,2% e 1,3%, comparativamente a 2010. O consumo total correspondeu a 1108 tep, sendo 66% relativo ao consumo de gás natural. Foi utilizado um analisador de energia eléctrica nos principais equipamentos consumidores, e na desagregação de consumos térmicos, efectuaram-se leituras no contador geral de gás natural e foram utilizados dados das auditorias ambiental e energética. O processo de cozedura é responsável por 58% do consumo térmico da instalação, seguido da pintura com 24%. A conformação é o sector com maior consumo de energia eléctrica, correspondendo a 23% do consumo total. As perdas térmicas pelos gases de exaustão dos equipamentos de combustão e pela envolvente do forno, considerando os mecanismos de convecção natural e radiação, correspondem a cerca de 6% do consumo térmico total, sendo necessário tomar medidas a nível do isolamento térmico e da redução do excesso de ar. A instalação de variadores de velocidade nos ventiladores do ar de combustão do forno poderia resultar em poupanças significativas, em particular, no consumo de gás natural – redução de 4 tep/ano e cerca de 2500€/ano– tendo um tempo de retorno do investimento inferior a 1 ano. Deverá ser, no entanto, garantida a alimentação de ar combustão a todos os queimadores, bem como, a combustão completa do gás natural. O funcionamento contínuo do forno poderia resultar no aumento da sua eficiência energética, com redução de custos de operação e manutenção, sendo necessário avaliar os custos adicionais de stock e de mão de obra. Verificou-se que as medidas relacionadas com a monitorização de consumos, eliminação de fugas de ar comprimido e a instalação de variadores de velocidade nos ventiladores do ar de combustão do forno poderiam resultar em reduções de consumo de 26 tep e de emissões de 66tCO2e, num total de quase 14 000€.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents a low cost architecture for development of synchronized phasor measurement units (PMU). The device is intended to be connected in the low voltage grid, which allows the monitoring of transmission and distribution networks. Developments of this project include a complete PMU, with instrumentation module for use in low voltage network, GPS module to provide the sync signal and time stamp for the measures, processing unit with the acquisition system, phasor estimation and formatting data according to the standard and finally, communication module for data transmission. For the development and evaluation of the performance of this PMU, it was developed a set of applications in LabVIEW environment with specific features that let analyze the behavior of the measures and identify the sources of error of the PMU, as well as to apply all the tests proposed by the standard. The first application, useful for the development of instrumentation, consists of a function generator integrated with an oscilloscope, which allows the generation and acquisition of signals synchronously, in addition to the handling of samples. The second and main, is the test platform, with capabality of generating all tests provided by the synchronized phasor measurement standard IEEE C37.118.1, allowing store data or make the analysis of the measurements in real time. Finally, a third application was developed to evaluate the results of the tests and generate calibration curves to adjust the PMU. The results include all the tests proposed by synchrophasors standard and an additional test that evaluates the impact of noise. Moreover, through two prototypes connected to the electrical installation of consumers in same distribution circuit, it was obtained monitoring records that allowed the identification of loads in consumer and power quality analysis, beyond the event detection at the distribution and transmission levels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The insertion of distributed generation units in the electric power systems have contributed to the popularization of microgrid concepts. With the microgrids, several potential benefits can be achieved in regard to power quality and supply reliability. However, several technical challenges related to the control and operation of microgrids, which are associated with high insertion of generation systems based on static converters, must be overcame. Among the opportunities in the context of microgrids, there is the islanded operation of microgrids temporarily disconnected from the electric power systems and also the autonomous operation of geographically isolated microgrids. The frequency in large power systems is traditionally controlled by the generation units based on traditional synchronous generator. The insertion of distributed generation units based on static power converters may bring difficulties to the frequency control in microgrids, due to the reduction of the equivalent inertia of conventional synchronous generators present in islanded and isolated microgrids. In this context, it becomes necessary the proposition of new operational and control strategies for microgrids control, taking into account the presence of distributed generation units based on full-rated converter. This paper proposes an operational and control strategy for the islanded operation of a winddiesel microgrid with high insertion level of wind generation. The microgrid adopted in this study comprises of a wind energy conversion system with synchronous generator based on full rated converter, a diesel generator (DIG) and a dump load. Due to the high insertion level of wind generation, the wind unit operates in Vf mode and the diesel generator operates in PQ mode. The diesel generator and the dump load are used to regulate the DC-link voltage of the wind generation unit. The proposed control allows the islanded operation of the microgrid only with wind generation, wind-only mode (WO), and with wind-diesel generation, wind-diesel mode (WD). For the wind-only mode, with 100% of penetration level of wind generation, it is proposed a DC-link voltage control loop based on the use of a DC dump load. For the winddiesel mode, it is proposed a DC-link voltage control loop added to the diesel generator, which is connected to the AC side of the microgrid, in coordinated action with the dump load. The proposed operational and control strategy does not require the use of batteries and aims to maximize the energy production from wind generation, ensuring the uninterrupted operation of the microgrid. The results have showed that the operational and control strategy allowed the stable operation of the islanded microgrid and that the DC-link voltage control loop added to the diesel generator and the dump load proved to be effective during the typical variations of wind speed and load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the growing interest in the issue of reducing powerconsumption in electricity applications, energy-saving devises and the problem of their operation gains more attention. The increase in the utilization of energy-saving lamps, especially LED lamps, leads to the wide interest in their influence on the power system. The impact of discussed devices on the voltage and current in the grid must be thoroughly studied before launching devices into the market. The studies undertaken on the LED lamps present in a wide range the issue of harmonic emission from lamps and their influence on power quality. Due to many anufacturing technologies, different LED devices can have various effects on the utility. It is significant to carry out researches concerning the adverse effects of energy-saving lamps in order to utilize devices that meet certain requirements which are set by the international commissions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an integrated model for an offshore wind turbine taking into consideration a contribution for the marine wave and wind speed with perturbations influences on the power quality of current injected into the electric grid. The paper deals with the simulation of one floating offshore wind turbine equipped with a permanent magnet synchronous generator, and a two-level converter connected to an onshore electric grid. The use of discrete mass modeling is accessed in order to reveal by computing the total harmonic distortion on how the perturbations of the captured energy are attenuated at the electric grid injection point. Two torque actions are considered for the three-mass modeling, the aerodynamic on the flexible part and on the rigid part of the blades. Also, a torque due to the influence of marine waves in deep water is considered. Proportional integral fractional-order control supports the control strategy. A comparison between the drive train models is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an integrated model for an offshore wind energy system taking into consideration a contribution for the marine wave and wind speed with perturbations influences on the power quality of current injected into the electric grid. The paper deals with the simulation of one floating offshore wind turbine equipped with a PMSG and a two-level converter connected to an onshore electric grid. The use of discrete mass modeling is accessed in order to reveal by computing the THD on how the perturbations of the captured energy are attenuated at the electric grid injection point. Two torque actions are considered for the three-mass modeling, the aerodynamic on the flexible part and on the rigid part of the blades. Also, a torque due to the influence of marine waves in deep water is considered. PI fractional-order control supports the control strategy. A comparison between the drive train models is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper focuses on technology state of the art for the charge/discharge of electric energy storage supported by vanadium redox flow battery linked to the electric grid. Properties of vanadium, the main configuration and the reaction of charge/discharge of a vanadium redox flow battery are addressed. The vanadium redox flow battery has the highest cell voltage among the other redox flow battery, implying higher power and energy density which favours application at power plants. This electric energy storage is viewed as a promising contribution to be integrated in power system due to a reasonably bulky size and to successful applications currently allowing storage of energy at power plants or at electrical grids. For instances, allowing storage of energy as an economic improvement providing spin reserve to avoid penalty for imbalances between the energy delivered and energy contracted at closing of electricity market or as an economic improvement to diminish the cost of electricity usage of a consumer. The vanadium redox flow battery has the advantages of scalability customized to meet requirements for power and energy capacity and of excellent combination of energy efficiency, capital cost and life cycle costs compared with other technology.