968 resultados para POLYMERIC ELECTROLYTES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the oriented (epitaxial) crystallization of thermoplastic polymers on oriented polymer substrates, generally the transmission electron microscopy (TEM) is used. With this instrument, the crystallized material can easily be resolved and orientation relationships can be monitored by electron diffraction. Disadvantages are the time consuming sample preparations and difficulties in the in-situ observations of the crystallization events, because of the radiation sensitivity of the polymer crystals. It is demonstrated that these disadvantages of the TEM can be eleminated by the use of different methods of light optical contrasts under specific preparation conditions of the samples and that the optical microscopy being a supplementary method to the TEM for investigations of epitaxial crystallization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the electrochemical oxidation and reduction of electroactive solutes which are dissolved in and diffusing through the polymer electrolyte solvent, poly(ethylene oxide) (PEO). The characteristics of electrochemical reactions in polymeric solutions are discussed, including how rigid solvent environments affect mass transport rates, and the transport phenomenon of electroactive species in PEO with bathing gases is explained by using the voltammetric theory of ultramicroelectrodes. The possibility that the microelectrode coated with PEO film can be used as a gas sensor has been discussed.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly-salen-Co(III) complexes were employed in the hydrolytic kinetic resolution (HKR) of terminal epoxides and ee's up to 98% were obtained. In the HKR of epichlorohydrin, the polymeric catalysts can be recovered and modified for recycling. The recovered polymer catalyst shows good activity and selectivity. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel design of a moving-coil transducer coupled with a low-hardness elastomer called “the gel surround” is presented in this thesis. This device is termed a “gel-type audio transducer”. The gel-type audio transducer has been developed to overcome the problems that conventional loudspeakers have suffered - that is, the problem with size of the audio device against the quality of sound at low frequency range. Therefore the research work presented herein aims to develop the “gel-type audio transducer” as a next-generation audio transducer for miniaturized woofers. The gel-type audio transducer consists of the magnetic and coil-drive plate assembly, and these parts are coupled by the gel surround. The transducer is driven by the electromagnetic conversion mechanism (a moving-coil transducer) and its output driving force can be greatly enhanced by applying the novel mechanism of the gel surround especially at low frequency range, resulting in the enhanced acoustic efficiency. The transducer can be attached to a stiff and light panel with both the optimized impedance matching and minimised wave collisions. The performance of the gel-type audio transducer is greatly influenced by the mass of the magnetic assembly and compliance of the “gel surround”. But as the size of the magnet and its weight have to be kept minimal for a miniaturisation of the device, the focus of the research is on the effect of the of the gel surround. As a result, the effect of the gel surround, made of the RTV (room-temperature vulcanising) silicone elastomer, TPE (thermoplastic elastomer), and the silicone foam, on generation of the output driving force, the energy transfer from the transducer to a panel to which the transducer is attached, and sound radiation from the vibrating panel, was investigated. This effect was studied by COMSOL multiphysics (FE analysis) and thereby, the simulated results were verified by experiments such as the laser scanning measurement, DMA (dynamic mechanical analyzer), and the acoustic test. Successful development of prototypes of the gel-type audio transducers, with an enhanced acoustic efficiency at reduced size and weight, was achieved. Implementation of the transducers into consumer applications was also demonstrated with their commercial values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

α-Tocopheryl succinate (α-TOS) is a well-known mitochondrially targeted anticancer compound, however, it is highly hydrophobic and toxic. In order to improve its activity and reduce its toxicity, new surfactant-free biologically active nanoparticles (NP) were synthesized. A methacrylic derivative of α-TOS (MTOS) was prepared and incorporated in amphiphilic pseudoblock copolymers when copolymerized with N-vinylpyrrolidone (VP) by free radical polymerization (poly(VP-co-MTOS)). The selected poly(VP-co-MTOS) copolymers formed surfactant-free NP by nanoprecipitation with sizes between 96 and 220 nm and narrow size distribution, and the in vitro biological activity was tested. In order to understand the structure-activity relationship three other methacrylic monomers were synthesized and characterized: MVE did not have the succinate group, SPHY did not have the chromanol ring, and MPHY did not have both the succinate group and the chromanol ring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensity and kinetics of the serum polymeric and monomeric immunoglobulin A1 (IgA1) and IgA2 antibody responses to Campylobacter jejuni were analyzed. A rapid and marked serum IgA antibody response involving both the monomeric and polymeric components of IgA was observed after C. jejuni infections. IgA antibodies reached a peak of activity in serum during week 2 after the first symptoms of enteritis, about 10 days before the peak of IgG activity. Polymeric IgA accounted for most of the anti-C. jejuni activity at the peak of the IgA response (median, 90%; range, 44 to 98%) but rapidly disappeared from serum over a few weeks. In contrast, the serum monomeric IgA antibody response was low and was maintained over a prolonged period of time. Anti-C. jejuni IgA detected in the serum of healthy blood donors was mainly monomeric (median, 83%; range, 17 to 94%). In both the patients and the positive controls, IgA1 was the predominant (greater than 85%) subclass involved, even when the IgA antibody response was mainly polymeric. Our results suggest that polymeric IgA antibody responses are linked to a strong or persisting antigenic stimulation or both. Polymeric IgA antibodies appear to be a potential marker of acute C. jejuni infections, and their determination could provide a useful tool for the serological diagnosis of recent C. jejuni infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

© The Royal Society of Chemistry.Force reactive functional groups, or mechanophores, have emerged as the basis of a potential strategy for sensing and countering stress-induced material failure. The general utility of this strategy is limited, however, because the levels of mechanophore activation in the bulk are typically low and observed only under large, typically irreversible strains. Strategies that enhance activation are therefore quite useful. Molecular-level design principles by which to engineer enhanced mechanophore activity are reviewed, with an emphasis on quantitative structure-activity studies determined for a family of gem-dihalocyclopropane mechanophores. This journal is

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) is a new therapeutic approach for the palliative treatment of malignant bile duct obstruction. In this study, we designed photosensitizer-embedded self-expanding nonvascular metal stent (PDT-stent) which allows repeatable photodynamic treatment of cholangiocarcinoma without systemic injection of photosensitizer. Polymeric photosensitizer (pullulan acetate-conjugated pheophorbide A; PPA) was incorporated in self-expanding nonvascular metal stent. Residence of PPA in the stent was estimated in buffer solution and subcutaneous implantation on mouse. Photodynamic activity of PDT-stent was evaluated through laserexposure on stent-layered tumor cell lines, HCT-116 tumor-xenograft mouse models and endoscopic intervention of PDT-stent on bile duct of mini pigs. Photo-fluorescence imaging of the PDT-stent demonstrated homogeneous embedding of polymeric Pheo-A (PPA) on stent membrane. PDT-stent sustained its photodynamic activities at least for 2 month. And which implies repeatable endoscopic PDT is possible after stent emplacement. The PDT-stent after light exposure successfully generated cytotoxic singlet oxygen in the surrounding tissues, inducing apoptotic degradation of tumor cells and regression of xenograft tumors on mouse models. Endoscopic biliary in-stent photodynamic treatments on minipigs also suggested the potential efficacy of PDT-stent on cholangiocarcinoma. In vivo and in vitro studies revealed our PDT-stent, allows repeatable endoscopic biliary PDT, has the potential for the combination therapy (stent plus PDT) of cholangiocarcinoma. © 2014 Elsevier Ltd.