991 resultados para Orthodontic appliance
Resumo:
Patients are looking for esthetic and functional changes when seeking orthodontic treatment and expect the remaining of a stable occlusion. Occlusion stability is one of the goals of the orthodontist; however, dental relationships changes in long-term can occur leading to a relapse of the treatment. Teeth and shape of arches tend to return to the original form, been the retention phase important after the appliance removal, even after several years of post-treatment. This article approaches a submission of a clinical case of Class II division 1 treated with extraction of premolars analyzing its long-term stability.
Resumo:
The aim of an orthodontic treatment is the achievement of a balanced, esthetic and, most of all, stable, intra and inter arches relationship. A common problem observed in occlusion is posterior crossbite and atresic maxilla. This problem may be treated by slow expansion, rapid expansion or surgically assisted expansion. For the present study cast models of 14 children between 7 and 11 years old were evaluated. There were 7 male and 7 female subjects that presented posterior crossbite and needed rapid maxillary expansion. The Hyrax appliance performed the therapy for correction of this transversal alteration, which is a common possibility in the treatment of this malocclusion. It was observed that the distance between the upper first molars and upper cuspids increased significantly; the length of the upper arch decreased and its perimeter increased significantly. At the lower arch there were no dimensional changes.
Resumo:
The Herbst appliance is currently one of the most used appliances for the correction of Class II division 1 with mandibular retrusion. When used in peak, or just after the peak of growth it can result in some skeletal gain, which is favorable to the correction of anteroposterior discrepancy with effective and stable results. This article aims to report a case of a patient with malocclusion Class II division 1 with mandibular retrusion, associated with maxillary protusion, treated in two stages: with Herbst splint metallic appliance followed by fixed appliance orthodontic treatment.
Resumo:
Direct bonding of orthodontics attachments to the teeth or restoration has become a routine in fixed appliance therapy. The technique used seems to be simple, but meticulous attention to detail and steps, a thorough understanding of factors involved are needed to ensure a successful outcome into different surfaces. It is the purpose of this article to review concerning aspects to orthodontic bonding in enamel and restorations fabricated from different materials; affording assistance to the reader wiser accomplishment and successful procedure.
Resumo:
Nowadays, the correction of skeletal vertical dysplasia is considered a great challenge in Orthodontics. The skeletal open bite treatment presents limitations related to vertical growth pattern, the extension of open bite and especially the stability, which is very questioned. The treatment of skeletal open bite is mostly realized by the inhibition of vertical alveolar posterior development (relative intrusion) or absolute intrusion of posterior teeth, through vertical forces, generated by the action of masticatory muscles. The purpose of this article is to present a new appliance for the treatment of skeletal open bite, the VABB (Vertically Activated Bite Block) or modified Bite Block, whose action mechanism is to limit the vertical development of the molars, by the action of facial muscles and two bilateral expansion screws that provide a counterclockwise rotation of the mandible. It will also be presented a clinical case and the technical steps for the construction of this appliance.
Resumo:
The Jasper Jumper appliance was developed as a fixed orthopedic device that is connected to the upper and lower leveling arches to promote the Class II correction by restricting the maxillary growth (headgear effect), mandibular growth inducement (activator effect) and dentoalveolar changes.
Resumo:
Extensive intraosseous lesions represent a clinical challenge for the periodontist. Sites with bone defects have been shown to be at higher risk of periodontitis progression in patients who had not received periodontal therapy. Thus, the aim of this case report was to describe a novel approach for the treatment of 1-walled intraosseous defect by combining nonsurgical periodontal therapy and orthodontic movement toward the bone defect, avoiding regenerative and surgical procedures. A 47-year-old woman underwent the proposed procedures for the treatment of her left central incisor with 9 mm probing depth and 1-walled intraosseous defect in its mesial aspect. Initially, basic periodontal therapy with scaling and root planning was accomplished. Two months later, an orthodontic treatment was planned to eliminate the intraosseous lesion and to improve the interproximal papillary area. Orthodontic root movement toward the osseous defect was performed for 13 months with light forces. After 6 years postoperative it was concluded that combined basic periodontal therapy and orthodontic movement was capable of eliminating the intraosseous defect and improve the esthetics in the interproximal papillary area between the central incisors.
Resumo:
Forced orthodontic eruption (FOE) is a non-surgical treatment option that allows modifying the osseous and gingival topography. The aim of this article is to present a clinical case of a FOE, which resulted in an improvement of the amount of available bone and soft-tissues for implant site development. Patient was referred for treatment of mobility and unesthetic appearance of their maxillary incisors. Clinical and radiographic examination revealed inflamed gingival tissue, horizontal and vertical tooth mobility and interproximal angular bone defects. It was chosen a multidisciplinary treatment approach using FOE, tooth extraction, and immediate implant placement to achieve better esthetic results. The use of FOE, in periodontally compromised teeth, promoted the formation of a new bone and soft-tissue in a coronal direction, without additional surgical procedures, enabling an esthetic, and functional implant-supported restoration.
Resumo:
The aim of this paper is to present a complex rehabilitation, of fractured tooth, with implants in anterior region considering the orthodontics extrusion to clinical success. At 7 years old, the patient fractured the maxillary left central incisor and the dentist did a crown with the fragment. Twenty years later, the patient was referred to a dental clinic for orthodontic treatment, with the chief complaint related to an accentuated deep bite, and a professional started an orthodontic treatment. After sixteen months of orthodontic treatment, tooth 21 fractured. The treatment plan included an orthodontic extrusion of tooth 21 and implant placement. This case has been followed up and the clinical and radiographic examinations show excellence esthetic results and satisfaction of patient. The forced extrusion can be a viable treatment option in the management of crown root fracture of an anterior tooth to gain bone in a vertical direction. This case emphasizes that to achieve the esthetic result a multidisciplinary approach is necessary.
Resumo:
The removal of resin debris and/or resin cement from the enamel surface without causing iatrogenic is the main objective when removing the orthodontic brackets. Some factors such as the time required for removal, damage to the tooth structure, are essential factors for the clinician at the time of removal. Various techniques are used for the removal of orthodontic brackets after the treatment; it is known that the use of clinical procedures such as the use of diamond burs and some pliers removers can damage the structure of the enamel, often depending on the bond strength that should be taken into consideration at the time of removal. This literature review aims to gather the most relevant studies that can clarify the clinical technique, which may be more suitable for removal of the brackets.
Resumo:
Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.
Resumo:
Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.