761 resultados para Organozinc reagent
Resumo:
The alizarin red S (ARS) has been used as a spectrophotometric reagent of several metals for a long time. Now this alizarin has been used as modifier agent of electrodes, for voltammetric analyses. In this work cyclic voltammetry experiments was accomplished on closed circuit, with the objective of studying the voltammetric behavior of alizarin red S adsorbed and of its copper complex, on the surface of the pyrolytic graphite electrode. These studies showed that ARS strongly adsorbs on the surface of this electrode. This adsorption was used to immobilize ions copper(II) from the solution.
Resumo:
Some modifications made at silanization step and the introduction of r-nitrobenzil bromide as an alternative reagent to the 8-hydroxiquinolein immobilization in silica gel were important points that brought up the reduction of synthesis time, efficency improvement of the immobilization process and better hydrolysis stabilization to the final materials. The caracterization was made by infrared spectroscopy, elementary analysis, complexing capacity and acid-base properties.
Resumo:
Didactic experiments are proposed in order to demonstrate the characteristics of flow injection analysis and to extend the applications of FIA to the determination of physical chemistry parameters in undergraduate labs. All experiments can be performed with the same flow manifold by employing usual FIA devices. Analytical characteristics are presented by means of the determination of iron in river water, employing 1,10-phenantroline as chromogenic reagent. Physical chemistry applications were the determination of reaction stoichiometries by continuous variation and mole-ratio methods and the evaluation of the pH and ionic strength effects on the kinetic of the reduction of hexacianoferrate(III) by ascorbic acid.
Resumo:
The present work proposes the application of the 4-Hidroxy-3-(2-hydroxynaphtylazo)-benzenesulphonic acid (C.I. 15670), Alizarine Violet N (AVN), as a reagent for direct aluminium determination using molecular absorption spectrophotometry in the presence of tensoatives. Al(III) cation reacts with AVN in pH 9.4, forming a red complex, stable for at least 24 hours, with absorption minimum at 607nm and, against a reagent blank, (epsiloncomplex - epsilonreagent) = -2.71x10(4) L.mol-1.cm-1. The reaction occurs in the presence of a Triton-X100 and CTAB tensoatives mixture, in the presence of EDTA. Al(III) determination is possible in the linear range of 50 up to 400ng.mL-1, with a detection limit of 41 ng.mL-1.
Resumo:
A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.
Resumo:
A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.
Resumo:
Diplomityön tarkoituksena oli tutkia ja kehittää menetelmä arvometallien kuten kuparin, sinkin, koboltin ja nikkelin talteenottoon metallikloridiliuoksesta. Tavoitteena oli valita taloudellisin ja ympäristöystävällisin menetelmä, jolla saadaan nämä arvometallit myyntituotteiksi. Lisäksi puhdistetun prosessiveden tuli täyttää asetetut tavoitteet. Kirjallisuustyön perusteella laskettiin viidelle eri prosessivaihtoehdolle ainetaseet HSC Sim 6.0 ohjelmalla, joka on HSC Chemistry-pohjainen prosessien simulointi- ja mallinnusohjelma. Kaikissa vaihtoehdoissa oli ensimmäisenä prosessiosana kuparin, sinkin, koboltin ja nikkelin sulfidisaostus ja sakan pesu. Sulfidisaostusta seurasi vaihtoehtoisesti joko 1) hapetus hapella ja hydroksidisaostus, 2) hapetus vetyperoksidilla ja hydroksidisaostus, 3) pelkkä hydroksidisaostus, 4) hapetus SO2/O2-kaasuseoksella ja hydroksidisaostus tai 5) karbonaattisaostus. Taselaskennan perusteella valittiin kokeelliseen osaan tutkittavat prosessivaihtoehdot, jotka olivat sulfidisaostus, hydroksidisaostus, SO2/O2- hapetus ja hydroksidisaostus sekä karbonaattisaostus. Kokeissa arvometallit saatiin talteenotettua sulfidisaostuksella selektiivisimmin lämpötilassa 55 °C ja pH:ssa 4. Näissä olosuhteissa reagenssin kulutus verrattaessa muihin tehtyihin sulfidisaostuksiin oli pienin. Sakka laskeutui ja suotautui hyvin. Loppusakan sisältämien metallien (kupari, sinkki ja koboltti) pitoisuudet olivat korkeimmat. Myös nikkelin määrä oli suuri. Mangaani ja rauta saatiin talteenotettua selektiivisimmin karbonaattisaostuksella lämpötilassa 65 °C. Sakka sisälsi eniten mangaania. Sakka laskeutui ja suotautui hyvin. Tällä menetelmällä puhdistetun prosessiveden laatu täytti asetetut tavoitteet.
Resumo:
An experiment showing the readily available disaccharide (sucrose) as reagent for experiments in undergraduate chemistry laboratory is described. The preparation of 2,3:4,5-di-O-isopropylidene-beta-D-fructopyranose from sucrose is very simple, uses low cost materials, requires two periods of 4 hours and is useful for classroom support in undergraduate courses.
Resumo:
In this paper we describe a powerful methodology for the regiospecific construction of polysubstituted aromatic and heteroaromatic compounds. The DoM reaction (direct ortho-metalation) comprises the deprotonation in position ortho of a aromatic or heteroaromatic containing DMG (directed metalation group) by strong bases, normally an alkyllithium reagent, leading to an ortho-lithiated species. These species, upon treatment with electrophilic reagents, gives 1,2 disubstituted products.
Resumo:
This paper presents an automatic procedure employing a reagent in the form of a slurry in a flow-injection system. The feasibility of the proposal is demonstrated by sulphate determination in water using the Barium Chloranilate method, which is based on the precipitation of barium sulphate. The release of a stoichiometric amount of highly colored chloranilic ions is monitored at 528 nm. The reaction is carried out in alcoholic medium in order to reduce the solubility of the reagent. A considerable improvement in the sensitivity is attained by adding ferric ions to the released chloranilic ions. An on-line filtration step to separate the excess reagent from the released chloranilic ions was necessary. In addition, a column containing a cation exchange resin was included in the manifold to remove potentially interfering ions. The proposed procedure is suitable for 30 determinations per hour and the relative standard deviation is less than 2%. The analytical curve is linear between 0.0 and 40 mg L-1 and the determination limit is about 2.0 mg L-1SO4(2-). Accuracy was confirmed by running several samples already analysed by a standard turbidimetric procedure.
Resumo:
Isotopic and elemental analysis of N, C and S in liquid and solid samples has been simplified with the advent of automated systems. The simplest method of automation for this kind of analysis involves an elemental analyzer interfaced directly to the ion source of an IRMS (Isotope Ratio Mass Spectrometry). In the analyzer reduction system, an expressive amount of oxidized copper is generated as solid residue. This material is normally imported and the price is very high. A methodology was proposed for the recovery of metallic copper in order to recycle this reagent in the reduction system of a GC-IRMS, using the hydrogen gas in the vacuum line. Results show that it is possible to obtain a recycle of about 95 % of the initial metallic copper used in the reduction system.
Resumo:
An alternative analytical method for nitrogen dioxide (NO2) in atmosphere was developed. The collection of NO2 is performed by a Sep-Pack C-18 cartridge impregnated with 11% (v/v) of triethanolamine plus 3,6 % (v/v) of ethylene glycol plus 25 % (v/v) of acetone combined solution. When the impregnating is used, NO2 is collected with good repeatibility (CV = 3,3 %). The NO2 absorbed in the sampler was stripped from the sorbent with a methanol 5% (v/v) aqueous solution and was determined by colorimetry as nitrite by using the Griess-Saltzman reagent. The detection limit of 1,4 ppb for 60 min sampling at 0,5 L min-1 flow rate was obtained. Preparation and conditioning procedures for TEA-C-18 cartridge, sampling flow rate, absorption capacity and interference of other species are discussed.
Resumo:
A brief discussion about the hydrogen peroxide importance and its determination is presented. It was emphasized some consideration of the H2O2 as reagent (separated or combined), uses and methods of analysis (techniques, detection limits, linear response intervals, sensor specifications). Moreover, it was presented several applications, such as in environmental, pharmaceutical, medicine and food samples.
Resumo:
In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.
Resumo:
The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.