1000 resultados para Optimization procedures
Resumo:
In this paper a solution to an highly constrained and non-convex economical dispatch (ED) problem with a meta-heuristic technique named Sensing Cloud Optimization (SCO) is presented. The proposed meta-heuristic is based on a cloud of particles whose central point represents the objective function value and the remaining particles act as sensors "to fill" the search space and "guide" the central particle so it moves into the best direction. To demonstrate its performance, a case study with multi-fuel units and valve- point effects is presented.
Resumo:
This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0%, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0%, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCEs) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35 degrees C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 min. In the hardened state, silica fumes increased not only the grout's porosity but also the grout's compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 d and beyond. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Mestrado em Engenharia Informática
Resumo:
We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg−1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.
Resumo:
A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon>2.3%) and LS (organic carbon<2.3%). Themethod was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrixmatched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70–120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg−1 and from 11.41 to 79.23 μg kg−1, respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg−1 and the limits of quantification from 20.37 to 49.27 μg kg−1. In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg−1) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.
Resumo:
Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid-phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18-E), benzenesulfonic acid modified silica cation exchanger (SA), poly (styrene-divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18-E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries>70% with standard deviations (SD)<15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′-DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET),maximum excitation energy or “q” value (q), and isolationmass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit.Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.
Resumo:
This paper aims to present a contrastive approach between three different ways of building concepts after proving the similar syntactic possibilities that coexist in terms. However, from the semantic point of view we can see that each language family has a different distribution in meaning. But the most important point we try to show is that the differences found in the psychological process when communicating concepts should guide the translator and the terminologist in the target text production and the terminology planning process. Differences between languages in the information transmission process are due to the different roles the different types of knowledge play. We distinguish here the analytic-descriptive knowledge and the analogical knowledge among others. We also state that none of them is the best when determining the correctness of a term, but there has to be adequacy criteria in the selection process. This concept building or term building success is important when looking at the linguistic map of the information society.
Resumo:
A maximização do potencial da abordagem cirúrgica conservadora da axila para o cancro da mama, como um método minimamente invasivo para a avaliação de metastização axilar, visando diminuir a morbilidade associada ao esvaziamento axilar completo, requer um método preciso para avaliação patológica intraoperatória. Esse método não foi ainda estabelecido. Imprints e corte de congelação do gânglio sentinela são os procedimentos comummente utilizados, apesar de uma sensibilidade e especificidade inferior à desejada. Actualmente, novas técnicas estão a ser desenvolvidas, que apesar da sua optimização, ainda não ultrapassam os resultados das utilizadas. Um total de 138 mulheres com cancro da mama, submetidas a cirurgia mamária por abordagem conservadora da axila, cuja utilização de imprints e cortes de congelação foram os métodos de avaliação intraoperatória do gânglio sentinela. Os diagnósticos dados pela observação dos cortes dos fragmentos do exame extemporâneo foram comparados com os obtidos nos cortes histológicos definitivos dos fragmentos fixados em formol e incluídos em parafina. Os resultados obtidos da avaliação do exame extemporâneo demonstraram sensibilidade de 79,1%, especificidade de 96,9%, com uma precisão de 91,4%. Não se obteve correlação entre os resultados do extemporâneo e os parâmetros de caracterização do exame extemporâneo e tumores. Os métodos, imprints e cortes de congelação, actualmente utilizados na nossa instituição apresentam bons resultados, mas a adopção de apenas um ou outro necessita de uma análise mais aprofundada dos dados relativos à metodologia utilizada nos extemporâneos, de forma a verificar a especificidade e sensibilidade individualizadas dos imprints e dos cortes de congelação. Se os imprints se revelarem semelhantes aos cortes de congelação, a sua utilização é preferencial uma vez que acarreta menores custos e são menos morosos. A implementação de novas técnicas será uma metodologia adoptar, pelos benefícios acrescidos, porém mais estudos e a optimização
Resumo:
O presente trabalho insere-se no âmbito do Mestrado de Engenharia Química, ramo Optimização Energética na Indústria Química e pretende-se efectuar a avaliação energética do Complexo Municipal de Piscinas de Folgosa, localizado no Concelho da Maia, tendo como principais bases os Decretos-Lei 78, 79 e 80 de 04 de Abril 2006. Uma vez que a área útil de pavimento do presente edifício é superior a 1000 m2, encontra-se englobado no conceito de Grande Edifício de Serviços (GES). A escolha do Complexo Municipal de Piscinas de Folgosa para a realização do presente estudo prendeu-se com o facto de ser um objectivo da Câmara Municipal, mais concretamente do Departamento de Conservação e Manutenção de Estruturas Municipais, dar inicio aos procedimentos necessários para a certificação energética dos diversos edifícios Municipais, aliado ao facto das piscinas serem um tipo de edifício desportivo de elevada complexidade em termos de gestão, um grande consumidor de energia e possuidor de uma elevada diversidade de equipamentos. O objectivo principal será o de caracterizar energeticamente o edifício e optimizar os consumos do mesmo, de forma a reduzir, não só os consumos energéticos e respectiva factura, mas também nas emissões dos gases de efeito de estufa (CO2), pelo que a ordem de trabalhos inclui a realização de: - Avaliação Energética de acordo com o n.º1 do artigo 2º e artigo 34º do D. L. 79/2006; - Verificação dos Requisitos de Condução e manutenção das instalações de Aquecimento, Ventilação e Ar Condicionado (AVAC); - Caracterização Energética do Edifício – Índice de Eficiência Energética. A metodologia seguida baseou-se na utilizada para a realização de uma auditoria energética, sendo que foram contempladas as seguintes etapas: estudo pormenorizado da legislação referente à certificação de edifícios; realização de um levantamento de consumos energéticos reais da instalação (com base nas facturas energéticas); das suas características funcionais e levantamento dos vários equipamentos consumidores de energia. O Complexo Municipal de Piscinas de Folgosa é uma instalação cuja média de consumo de energia eléctrica nos últimos três anos foi de 445969 kWh/ano e de 87300 m3 de gás natural, representando um consumo global de energia primária de 174,85 tep/ano. De acordo com o Sistema de Certificação Energética o Índice de Eficiência Energética determinado é de 54,50 kgep/m2 .ano. Uma vez que o IEE determinado é superior ao valor de IEEReferência existentes, o edifício estará obrigado ao cumprimento de um Plano de Racionalização Energética (PRE). É apresentado um conjunto de medidas que visam uma redução do consumo de energia do edifício e consequentemente uma melhoria no Índice de Eficiência Energética.
Resumo:
55th European Regional Science Association Congress, Lisbon, Portugal (25-28 August 2015).
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Este trabalho foi realizado no âmbito da disciplina de Dissertação/Estágio do ramo de Optimização Energética na Indústria Química, do Mestrado em Engenharia Química do Instituto Superior de Engenharia do Porto e foi desenvolvido na empresa Refinarias de Açúcar Reunidas, S.A (RAR Açúcar). Face à crise energética mundial e à globalização, o custo de produção aumentou consideravelmente nos processos industriais e os mercados ficaram mais competitivos. Estes aspectos levam a que cada vez mais os responsáveis industriais se concentrem em encontrar soluções que contrariem estes aspectos. Nesta perspectiva, a questão da conservação da energia na indústria torna-se uma medida fundamental a adoptar na política interna de uma indústria. Na década de 80 as técnicas de integração revelaram-se como uma ferramenta muito útil na área da integração térmica de processos. O conceito destas técnicas focaliza-se numa maior recuperação de energia, um menor consumo de utilidades e consequentemente uma diminuição de custos. Este trabalho tem como objectivo realizar um Levantamento e uma Integração Energética do Processo de Refinação de Açúcar. O conhecimento profundo do processo de refinação do açúcar, assim como o conhecimento de todas as fases do processo da empresa foram um ponto de partida fundamental para o desenrolar do trabalho. O levantamento energético, a nível térmico, a todos os equipamentos das linhas de produção forneceu os dados necessários para a Integração do Processo de Refinação de Açúcar através da Metodologia de Pinch. Como resultado da aplicação da Metodologia Pinch foram introduzidos oito permutadores de calor obtendo-se uma recuperação de calor igual a (confidencial) kJ/dia aliada a um investimento de (confidencial). A recuperação energética alcançada traduz-se numa poupança de (confidencial)de nafta/ano sendo o investimento proposto recuperado em 1,2 anos.
Resumo:
Over the last two decades the research and development of legged locomotion robots has grown steadily. Legged systems present major advantages when compared with ‘traditional’ vehicles, because they allow locomotion in inaccessible terrain to vehicles with wheels and tracks. However, the robustness of legged robots, and especially their energy consumption, among other aspects, still lag behind mechanisms that use wheels and tracks. Therefore, in the present state of development, there are several aspects that need to be improved and optimized. Keeping these ideas in mind, this paper presents the review of the literature of different methods adopted for the optimization of the structure and locomotion gaits of walking robots. Among the distinct possible strategies often used for these tasks are referred approaches such as the mimicking of biological animals, the use of evolutionary schemes to find the optimal parameters and structures, the adoption of sound mechanical design rules, and the optimization of power-based indexes.
Resumo:
Conferência: 39th Annual Conference of the IEEE Industrial-Electronics-Society (IECON) - NOV 10-14, 2013