994 resultados para Olin R. Thompson


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Amygdala-orbitofrontal cortical (OFC) functional connectivity (FC) to emotional stimuli and relationships with white matter remain little examined in bipolar disorder individuals (BD). Methods: Thirty-one BD (type 1; n = 17 remitted; n = 14 depressed) and 24 age- and gender-ratio-matched healthy individuals (HC) viewed neutral, mild, and intense happy or sad emotional faces in two experiments. The FC was computed as linear and nonlinear dependence measures between amygdala and OFC time series. Effects of group, laterality, and emotion intensity upon amygdala-OFC FC and amygdala-OFC FC white matter fractional anisotropy (FA) relationships were examined. Results: The BD versus HC showed significantly greater right amygdala-OFC FC (p <= .001) in the sad experiment and significantly reduced bilateral amygdala-OFC FC (p = .007) in the happy experiment. Depressed but not remitted female BD versus female HC showed significantly greater left amygdala-OFC FC (p = .001) to all faces in the sad experiment and reduced bilateral amygdala-OFC FC to intense happy faces (p = .01). There was a significant nonlinear relationship (p = .001) between left amygdala-OFC FC to sad faces and FA in HC. In BD, antidepressants were associated with significantly reduced left amygdala-OFC FC to mild sad faces (p = .001). Conclusions: In BD, abnormally elevated right amygdala-OFC FC to sad stimuli might represent a trait vulnerability for depression, whereas abnormally elevated left amygdala-OFC FC to sad stimuli and abnormally reduced amygdala-OFC FC to intense happy stimuli might represent a depression state marker. Abnormal FC measures might normalize with antidepressant medications in BD. Nonlinear amygdala-OFC FC-FA relationships in BID and HC require further study.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare morphometric data of the eyelid fissure and the levator muscle function (LF) before and up to 6 months after transcutaneous injection with five units of Botox (R) in patients with upper lid retraction (ULR) from congestive or fibrotic thyroid eye disease (TED). Methods Twenty-four patients with ULR from TED were submitted to transcutaneous injection of 5 units (0.1 ml) of Botox in one eye only. Patients were divided into two groups: 12 with congestive-stage TED (CG), and 12 with fibrotic-stage TED (FG). Bilateral lid fissure measurements using digital imaging and computer-aided analysis were taken at baseline and at regular intervals 2 weeks, 1 month, 3 months and 6 months after unilateral Botox injection. Mean values taken at different follow-up points were compared for the two groups. Results Most patients experienced marked improvement in ULR, with a mean reduction of 3.81 mm in FG and 3.05 mm in CG. The upper eyelid margin reflex distance, fissure height and total area of exposed interpalpebral fissure were significantly smaller during 1 month in CG and during 3 months in FG. Reduction in LF and in the difference between lateral and medial lid fissure measurements was observed in both groups. The treatment lasted significantly longer in FG than in CG. Conclusions A single 5-unit Botox injection improved ULR, reduced LF and produced an adequate lid contour in patients with congestive or fibrotic TED. The effect lasts longer in patients with fibrotic orbitopathy than in patients with congestive orbitopathy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some components of the kinin system such as plasma kallikrein levels, the activities of tissue kallikrein (including saliva) and kininase II and the concentrations of kininogen fractions (low-molecular weight/LKg and high-molecular weight/HKg) were evaluated in the plasma of patients with thromboangiitis obliterans (TAO) presenting clinical symptoms of the condition. Twenty TAO were diagnosed by means of the traditional Shionoya and Olin criteria and later classified into non-smokers (n = 11) and active smokers (n = 9). Fifty-three normal, non-smoking/smoking individuals (control) were also studied. Kininogen levels were determined by ELISA; the activities of kallikreins and kininase II were determined using selective substrates. The levels of enzymes (kallikreins and kininase II) and protein (kininogens) were significantly higher in patients with TAO who were active smokers compared to the control groups (no matter whether control individuals were active smokers or non-smokers, P < 0.001 for all comparisons). Interestingly, regardless of the time of disease onset, a significant increase in the levels of these components of the kinin system was also observed in patients when TAO active smokers were compared with TAO ex-smokers (P < 0.01 for all analysed parameters). Activation of the kinin system in patients with TAO may indicate the involvement of vasodilatation in an attempt to control vascular changes, thereby favouring the deposition of immune complexes at the vascular level because of nicotine stimulation. Moreover, our results corroborate the idea that TAO can be an autoimmune disorder with specific mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the arterial response to cobalt-chromium stents with and without polymer coating (Camouflage (R), Hemoteq AG, Wuerselen, Germany) implanted in pigs. Cobalt-chromium balloon-expandable stents (4 x 16 mm) were implanted in the common carotid arteries of nine pigs. Histological analysis of endothelialization, inflammation and injury was performed one month later. All stents were successfully deployed, and all but one animal survived the 30 study days. All arteries were patent. Endothelialization was nearly complete in most sections of all carotid stents in both groups. There were mild inflammatory infiltrate and mild-to-moderate injury, which were associated with the stent shafts and not significantly different between groups. Our findings suggest that, in porcine carotid arteries, the histological response to balloon-expandable cobalt-chromium stents coated with polymer (Camouflage (R), Hemoteq AG) is similar to the response to non-coated cobalt-chromium stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it`s more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnitude of the basic reproduction ratio R(0) of an epidemic can be estimated in several ways, namely, from the final size of the epidemic, from the average age at first infection, or from the initial growth phase of the outbreak. In this paper, we discuss this last method for estimating R(0) for vector-borne infections. Implicit in these models is the assumption that there is an exponential phase of the outbreaks, which implies that in all cases R(0) > 1. We demonstrate that an outbreak is possible, even in cases where R(0) is less than one, provided that the vector-to-human component of R(0) is greater than one and that a certain number of infected vectors are introduced into the affected population. This theory is applied to two real epidemiological dengue situations in the southeastern part of Brazil, one where R(0) is less than one, and other one where R(0) is greater than one. In both cases, the model mirrors the real situations with reasonable accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of the ion exchange treatment on the R-curve behavior of a leucite-reinforced dental porcelain, testing the hypothesis that the ion exchange is able to improve the R-curve behavior of the porcelain studied. Porcelain disks were sintered, finely polished, and submitted to an ion exchange treatment with a KNO(3) paste. The R-curve behavior was assessed by fracturing the specimens in a biaxial flexure design after making Vickers indentations in the center of the polished surface with loads of 1.8, 3.1, 4.9, 9.8, 31.4, and 49.0 N. The results showed that the ion exchange process resulted in significant improvements in terms of fracture toughness and flexural strength as compared to the untreated material. Nevertheless, the rising R-curve behavior previously observed in the control group disappeared after the ion exchange treatment, i.e., fracture toughness did not increase with the increase in crack size for the treated group.