785 resultados para Multifocal intraocular lens
Resumo:
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.
Resumo:
BACKGROUND: Intraocular gas bubbles expand as patients move up to higher altitude. This may cause an acute intraocular pressure (IOP) rise with associated vascular obstructions and visual loss. MATERIALS AND METHODS: Two pseudophakic patients underwent a pars plana vitrectomy and 23% SF6 gas tamponade for a pseudophakic retinal detachment. During the immediate post-operative phase, the patients travelled daily up to their domicile, which was situated approximately 600 m higher than the level where they had been operated on. These travels were always without any pain or visual loss. However 1 week after surgery both patients developed severe ocular pain, and one patient had complete temporary loss of vision after ascending to altitude levels, which had previously presented no problem. Both episodes occurred in parallel with a change in barometric pressure. RESULTS: Treatment with acetazolamide reduced the increased IOP to normal levels, and visual acuity recovered. CONCLUSIONS: Although the post-operative size of an intraocular gas bubble decreases progressively over time, problems with bubble expansion may still occur even at a late stage if meteorological factors, that may increase the bubble size, change.
Resumo:
Sèrie de casos restrospectiva observacional. Es van recollir les dades de 17 casos amb dislocació tardana del complex sac capsular – lent intraocular i que varen necessitar cirurgia per a la seva correcció a l’Hospital de l’Esperança entre Gener de l’any 2000 i Desembre de 2009. Van avaluar-se les característiques dels pacients, possibles factors de risc, condicions i patologies associades, tècnica per a l’extracció de la cataracta i el temps esdevingut entre ambdues cirurgies. Volem descriure les característiques dels casos i formular noves hipòtesi a estudi amb l’objectiu de prevenir i millorar el maneig d’aquesta complicació.
Resumo:
Objectiu: Valorar lent intraocular tòrica en astigmatisme i cataracta. Estudi observacional prospectiu; n: 21 astigmatisme igual o major a 1,5 D. Es valora Astigmatisme, agudesa visual pre operatòria, 1 setmana i 1 mes postoperatori. Eix d'implantació de la lent planificada, a les 24 hores i al mes. Es mesura astigmatisme residual refractiu al mes. N: 21 Astigmatisme preoperatori 2,42 D, astigmatisme 1 mes postoperatori 2,31 D Astigmatisme refractiu 1 mes postoperatori 1,05. Rotació al mes postoperatori 6,82 graus. Agudesa visual 1 mes postoperatori 0,7. La lent és útil en pacients sotmesos a cirurgia de cataracta amb astigmatisme preexistent.
Resumo:
INTRODUCCIÓ: Valorar els resultats funcionals i quirúrgics posteriors a l’explant de la lent intraocular H60M opacificada. MATERIAL I MÈTODES: Estudi retrospectiu de vint-i-cinc ulls sotmesos a intercanvi de H60M opacificada. Anàlisi dels resultats visuals i complicacions, abans, durant i després de l’explante. RESULTATS: Trobarem millors resultats visuals i una menor taxa de complicacions quan no associem vitrectomia anterior a la cirurgia, així como amb la col•locació de la lent secundaria a sulcus. CONCLUSIÓ: L’intercanvi de la LIO Hidroview opacificada suposa un risc quirúrgic addicional, que podem minimitzar durant el període intraoperatori intentant preservar les estructures oculars el més anatòmicament possible.
Resumo:
PURPOSE: To determine the mechanisms and treatment of ocular hypertension in patients with thyroid-associated orbitopathy and to differenciate it from glaucomatous damage. DESIGN: Three case reports. METHODS: Retrospective review of clinical findings, course, and treatment of the three patients. RESULTS: Elevated intraocular pressure in thyroid-associated orbitopathy observed in the three cases may involve different physiopathological abnormalities such as disturbances of venous circulation, compression by infiltrative muscles, and long corticosteroid use. In the first two cases, defects demonstrated in the perimetry are in consistent with glaucomatous damage. In the third case, visual field abnormalities may be compatible with a glaucomatous disease, but all defects resolved after therapy. Treatement was of the greatest difficulty for the three cases, associating antiglaucomatous medication, steroids, orbital radiotherapy, orbital decompression and extraocular muscle surgery. Intraocular pressure was controlled in all cases. CONCLUSIONS: Elevated intraocular pressure in thyroid-associated orbitopathy is distinguished from glaucomatous disease by its physiopathological mechanisms, clinical course, visual field defects, and treatment. The management of this hypertension is closely related to the treatment of dysthyroid orbitopathy.
Resumo:
Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.
Resumo:
The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.
Resumo:
PURPOSE: To report the case of a patient with undiagnosed Hodgkin's lymphoma who presented with coexistent unilateral nodular episcleritis and scleritis. DESIGN: Interventional case report and literature review METHODS: Review of clinical history, laboratory findings, histology of episcleral and cervical lymph node biopsies, and follow-up. RESULTS: A 20-year-old female presented with a 5-month history of redness and pain in her left eye, with associated symptoms of dyspnea, malaise, and fever. The patient was found to have multifocal nodular episcleritis and scleritis that was not responsive to topical steroids or systemic nonsteroidal anti-inflammatory treatment. Laboratory tests subsequently revealed evidence of systemic inflammation, and radiologic studies showed extensive mediastinal and cervical adenopathy. A cervical lymph node biopsy showed Reed-Sternberg cells and a chronic lymphocytic infiltrate consistent with nodular sclerosing Hodgkin's lymphoma. Histopathologic analysis of an episcleral nodule revealed a necrotizing granuloma with vasculitis. Systemic chemotherapy was instituted for the Hodgkin's disease; this therapy abolished the nodular scleritis. CONCLUSIONS: This case raises the possibility of concurrent undiagnosed systemic vasculitis with only an ocular manifestation with Hodgkin's lymphoma, either as a coincidence or as a paraneoplastic syndrome. Moreover, it emphasizes the important role of tissue biopsy in establishing diagnosis and directing treatment.
Resumo:
Aquest document de treball mira d'establir un nou camp d'investigació a la cruïlla entre els fluxos de migració i d'informació i comunicació. Hi ha diversos factors que fan que valgui la pena adoptar aquesta perspectiva. El punt central és que la migració internacional contemporània és incrustada en la dinàmica de la societat de la informació, seguint models comuns i dinàmiques interconnectades. Per consegüent, s'està començant a identificar els fluxos d'informació com a qüestions clau en les polítiques de migració. A més, hi ha una manca de coneixement empíric en el disseny de xarxes d'informació i l'ús de les tecnologies d'informació i comunicació en contextos migratoris. Aquest document de treball també mira de ser una font d'hipòtesis per a investigacions posteriors.
Resumo:
Objective: To determine the values of, and study the relationships among, central corneal thickness (CCT), intraocular pressure (IOP), and degree of myopia (DM) in an adult myopic population aged 20 to 40 years in Almeria (southeast Spain). To our knowledge this is first study of this kind in this region. Methods: An observational, descriptive, cross-sectional study was done in which a sample of 310 myopic patients (620 eyes) aged 20 to 40 years was selected by gender- and age-stratified sampling, which was proportionally fixed to the size of the population strata for which a 20% prevalence of myopia, 5% epsilon, and a 95% confidence interval were hypothesized. We studied IOP, CCT, and DM and their relationships by calculating the mean, standard deviation, 95% confidence interval for the mean, median, Fisher’s asymmetry coefficient, range (maximum, minimum), and the Brown-Forsythe’s robust test for each variable (IOP, CCT, and DM). Results: In the adult myopic population of Almeria aged 20 to 40 years (mean of 29.8), the mean overall CCT was 550.12 μm. The corneas of men were thicker than those of women (P = 0.014). CCT was stable as no significant differences were seen in the 20- to 40-year-old subjects’ CCT values. The mean overall IOP was 13.60 mmHg. Men had a higher IOP than women (P = 0.002). Subjects over 30 years (13.83) had a higher IOP than those under 30 (13.38) (P = 0.04). The mean overall DM was −4.18 diopters. Men had less myopia than women (P < 0.001). Myopia was stable in the 20- to 40-year-old study population (P = 0.089). A linear relationship was found between CCT and IOP (R2 = 0.152, P ≤ 0.001). CCT influenced the IOP value by 15.2%. However no linear relationship between DM and IOP, or between CCT and DM, was found. Conclusions: CCT was found to be similar to that reported in other studies in different populations. IOP tends to increase after the age of 30 and is not accounted for by alterations in CCT values.
Resumo:
When unmanned underwater vehicles (UUVs) perform missions near the ocean floor, optical sensors can be used to improve local navigation. Video mosaics allow to efficiently process the images acquired by the vehicle, and also to obtain position estimates. We discuss in this paper the role of lens distortions in this context, proving that degenerate mosaics have their origin not only in the selected motion model or in registration errors, but also in the cumulative effect of radial distortion residuals. Additionally, we present results on the accuracy of different feature-based approaches for self-correction of lens distortions that may guide the choice of appropriate techniques for correcting distortions
Resumo:
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.
Resumo:
Candida albicans is a common member of the human microbiota and may cause invasive disease in susceptible populations. Several risk factors have been proposed for candidaemia acquisition. Previous Candida multifocal colonisation among hospitalised patients may be crucial for the successful establishment of candidaemia. Nevertheless, it is still not clear whether the persistence or replacement of a single clone of C. albicans in multiple anatomical sites of the organism may represent an additional risk for candidaemia acquisition. Therefore, we prospectively evaluated the dynamics of the colonising strains of C. albicans for two groups of seven critically ill patients: group I included patients colonised by C. albicans in multiple sites who did not develop candidaemia and group II included patients who were colonised and who developed candidaemia. ABC and microsatellite genotyping of 51 strains of C. albicans revealed that patients who did not develop candidaemia were multiply colonised by at least two ABC genotypes of C. albicans, whereas candidaemic patients had highly related microsatellites and the same ABC genotype in colonising and bloodstream isolates that were probably present in different body sites before the onset of candidaemia.
Resumo:
BACKGROUND: The activity of melanopsin containing intrinsically photosensitive ganglion retinal cells (ipRGC) can be assessed by a means of pupil responses to bright blue (appr.480 nm) light. Due to age related factors in the eye, particularly, structural changes of the lens, less light reaches retina. The aim of this study was to examine how age and in vivo measured lens transmission of blue light might affect pupil light responses, in particular, mediated by the ipRGC. METHODS: Consensual pupil responses were explored in 44 healthy subjects aged between 26 and 68 years. A pupil response was recorded to a continuous 20 s light stimulus of 660 nm (red) or 470 nm (blue) both at 300 cd/m2 intensity (14.9 and 14.8 log photons/cm2/s, respectively). Additional recordings were performed using four 470 nm stimulus intensities of 3, 30, 100 and 300 cd/m2. The baseline pupil size was measured in darkness and results were adjusted for the baseline pupil and gender. The main outcome parameters were maximal and sustained pupil contraction amplitudes and the postillumination response assessed as area under the curve (AUC) over two time-windows: early (0-10 s after light termination) and late (10-30 s after light termination). Lens transmission was measured with an ocular fluorometer. RESULTS: The sustained pupil contraction and the early poststimulus AUC correlated positively with age (p=0.02, p=0.0014, respectively) for the blue light stimulus condition only.The maximal pupil contraction amplitude did not correlate to age either for bright blue or red light stimulus conditions.Lens transmission decreased linearly with age (p<0.0001). The pupil response was stable or increased with decreasing transmission, though only significantly for the early poststimulus AUC to 300 cd/m2 light (p=0.02). CONCLUSIONS: Age did not reduce, but rather enhance pupil responses mediated by ipRGC. The age related decrease of blue light transmission led to similar results, however, the effect of age was greater on these pupil responses than that of the lens transmission. Thus there must be other age related factors such as lens scatter and/or adaptive processes influencing the ipRGC mediated pupil response enhancement observed with advancing age.