928 resultados para Month
Resumo:
Background The e-Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth (e-HEALING) registry was designed to capture clinical data on the use of the endothelial progenitor cell capture stent (ECS) in routine clinical practice. In this analysis, we investigated the 12-month clinical outcomes in patients treated with an ECS for a bifurcation lesion. Methods The worldwide, prospective, nonrandomized e-HEALING registry aimed to enrol 5000 patients treated for coronary artery disease with one or more ECS between October 2005 and October 2007. Clinical follow-up was obtained at 1, 6, and 12 months. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, myocardial infarction, and target vessel revascularization at 12 months. Results A total of 573 patients were treated for at least one bifurcation lesion and were assessed in the current analysis. Baseline characteristics showed a median age of 65 years; 21% were diabetic patients and 36% had unstable angina. A total of 63% of the bifurcation lesions were located in the left artery descending and the mean stent length was 20.7 +/- 12.6 mm. At 12 months, TVF was 12.7% and target lesion revascularization was 7.5%. Definite or probable stent thrombosis occurred in 1.7% of the patients. Moreover, one or more stents per lesion [hazard ratio (HR): 2.79, 95% confidence interval (CI): 1.60-4.86, P < 0.001], predilatation (HR: 0.39, 95% CI: 0.17-0.87, P = 0.023), and lesions located in the right coronary artery (HR: 4.56, 95% CI: 1.07-19.5, P = 0.041) were independent predictors of TVF. Conclusion In the e-HEALING registry, coronary bifurcation stenting with the ECS results in favorable clinical outcomes and low incidences of repeat revascularization and stent thrombosis. Coron Artery Dis 23:201-207 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Objective To assess several baseline risk factors that may predict patellofemoral and tibiofemoral cartilage loss during a 6-month period. Methods For 177 subjects with chronic knee pain, 3T magnetic resonance imaging (MRI) of both knees was performed at baseline and followup. Knees were semiquantitatively assessed, evaluating cartilage morphology, subchondral bone marrow lesions, meniscal morphology/extrusion, synovitis, and effusion. Age, sex, and body mass index (BMI), bone marrow lesions, meniscal damage/extrusion, synovitis, effusion, and prevalent cartilage damage in the same subregion were evaluated as possible risk factors for cartilage loss. Logistic regression models were applied to predict cartilage loss. Models were adjusted for age, sex, treatment, and BMI. Results Seventy-nine subregions (1.6%) showed incident or worsening cartilage damage at followup. None of the demographic risk factors was predictive of future cartilage loss. Predictors of patellofemoral cartilage loss were effusion, with an adjusted odds ratio (OR) of 3.5 (95% confidence interval [95% CI] 1.39.4), and prevalent cartilage damage in the same subregion with an adjusted OR of 4.3 (95% CI 1.314.1). Risk factors for tibiofemoral cartilage loss were baseline meniscal extrusion (adjusted OR 3.6 [95% CI 1.310.1]), prevalent bone marrow lesions (adjusted OR 4.7 [95% CI 1.119.5]), and prevalent cartilage damage (adjusted OR 15.3 [95% CI 4.947.4]). Conclusion Cartilage loss over 6 months is rare, but may be detected semiquantitatively by 3T MRI and is most commonly observed in knees with Kellgren/Lawrence grade 3. Predictors of patellofemoral cartilage loss were effusion and prevalent cartilage damage in the same subregion. Predictors of tibiofemoral cartilage loss were prevalent cartilage damage, bone marrow lesions, and meniscal extrusion.
Resumo:
Purpose: This prospective randomized matched-pair controlled trial aimed to evaluate marginal bone levels and soft tissue alterations at implants restored according to the platform-switching concept with a new inward-inclined platform and compare them with external-hexagon implants. Materials and Methods: Traditional external-hexagon (control group) implants and inward-inclined platform implants (test group), all with the same implant body geometry and 13 mm in length, were inserted in a standardized manner in the posterior maxillae of 40 patients. Radiographic bone levels were measured by two independent examiners after 6, 12, and 18 months of prosthetic loading. Buccal soft tissue height was measured at the time of abutment connection and 18 months later. Results: After 18 months of loading, all 80 implants were clinically osseointegrated in the 40 participating patients. Radiographic evaluation showed mean bone losses of 0.5 +/- 0.1 mm (range, 0.3 to 0.7 mm) and 1.6 +/- 0.3 mm (range, 1.1 to 2.2 mm) for test and control implants, respectively. Soft tissue height showed a significant mean decrease of 2.4 mm in the control group, compared to 0.6 mm around the test implants. Conclusions: After 18 months, significantly greater bone loss was observed at implants restored according to the conventional external-hexagon protocol compared to the platform-switching concept. In addition, decreased soft tissue height was associated with the external-hexagon implants versus the platform-switched implants. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:927-934.
Resumo:
Objective: This study evaluated the 56-month clinical performance of Class I and II resin composite restorations. Filtek P60 was compared with Filtek Z250, which are both indicated for posterior restorations but differ in terms of handling characteristics. The null hypothesis tested was that there is no difference in the clinical performance of the two resin composites in posterior teeth. Material and Methods: Thirty-three patients were treated by the same operator, who prepared 48 Class I and 42 Class II cavities, which were restored with Single Bond/Filtek Z250 or Single Bond/Filtek P60 restorative systems. Restorations were evaluated by two independent examiners at baseline and after 56 months, using the modified USPHS criteria. Data were analyzed statistically using Chi-square and Fisher's Exact tests (alpha=0.05). Results: After 56 months, 25 patients (31 Class I and 36 Class II) were analyzed. A 3% failure rate occurred due to secondary caries and excessive loss of anatomic form for P60. For both restorative systems, there were no significant differences in secondary caries and postoperative sensitivity. However, significant changes were observed with respect to anatomic form, marginal discoloration, and marginal adaptation. Significant decreases in surface texture were observed exclusively for the Z250 restorations. Conclusions: Both restorative systems can be used for posterior restorations and can be expected to perform well in the oral environment.
Resumo:
Benesi F.J., Teixeira C. M. C., Lisboa J.A.N., Leal M. L. R., Birgel Jr E. H., Bohland E. & Mirandola R. M. S. 2012. [Erytrogram of healthy female Holstein calves during the first month of life.] Eritrograma de bezerras sadias, da raca Holandesa, no primeiro mes de vida. Pesquisa Veterinaria Brasileira 32(4): 357-360. Departamento de Cl nica Medica, Faculdade de Medicina Veterinaria e Zootecnia, Universidade de Sao Paulo, Campus Universitario, Av. Prof. Dr. Orlando Marques de Paiva 87, Sao Paulo, SP 05508-000, Brazil. E-mail: febencli@usp.br In order to establish reference values, and to assess the in fluence of the age factor on the erytrogram of healthy Holstein calves, blood samples from 300 animals were used, spread over 15 experimental groups, according to age, in the first month of life. Variations of the average values for the components of erytrogram were as follows: number of red blood cells (x10(6)/mm(3)) = 6.68-7.60, packed cell volume (%) = 29.80-33.35, hemoglobin concentration (g/dl) = 9.00-10.43, mean corpuscular volume (fl) = 38.93-47.68, mean corpuscular hemoglobin (pg) = 11.75-14.69, mean corpuscular hemoglobin concentration (%) = 29.53-31.63% and number of reticulocytes (x10(3)/mm(3)) = 0.00-11.86. The in fluence of the age factor proved to be significant for the mean corpuscular volume, mean corpuscular hemoglobin and the number of reticulocytes.
Resumo:
OBJECTIVE: The establishment of the intestinal microbiota in newborns is a critical period with possible long-term consequences for human health. In this research, the development of the fecal microbiota of a group of exclusively breastfed neonates living in low socio-economic conditions in the city of Sao Paulo, Brazil, during the first month of life, was studied. METHODS: Fecal samples were collected from ten neonates on the second, seventh, and 30th days after birth. One of the neonates underwent antibiotic therapy. Molecular techniques were used for analysis; DNA was extracted from the samples, and 16S rRNA libraries were sequenced and phylogenetically analyzed after construction. A real-time polymerase chain reaction (PCR) was performed on the samples taken from the 30th day to amplify DNA from Bifidobacterium sp. RESULTS: The primary phylogenetic groups identified in the samples were Escherichia and Clostridium. Staphylococcus was identified at a low rate. Bifidobacterium sp. was detected in all of the samples collected on the 30th day. In the child who received antibiotics, a reduction in anaerobes and Escherichia, which was associated with an overgrowth of Klebsiella, was observed throughout the experimental period. CONCLUSION: The observed pattern of Escherichia predominance and reduced Staphylococcus colonization is in contrast with the patterns observed in neonates living in developed countries.
Resumo:
BACKGROUND Cushing's disease is associated with high morbidity and mortality. Pasireotide, a potential therapy, has a unique, broad somatostatin-receptor-binding profile, with high binding affinity for somatostatin-receptor subtype 5. METHODS In this double-blind, phase 3 study, we randomly assigned 162 adults with Cushing's disease and a urinary free cortisol level of at least 1.5 times the upper limit of the normal range to receive subcutaneous pasireotide at a dose of 600 mu g (82 patients) or 900 mu g (80 patients) twice daily. Patients with urinary free cortisol not exceeding 2 times the upper limit of the normal range and not exceeding the baseline level at month 3 continued to receive their randomly assigned dose; all others received an additional 300 mu g twice daily. The primary end point was a urinary free cortisol level at or below the upper limit of the normal range at month 6 without an increased dose. Open-label treatment continued through month 12. RESULTS Twelve of the 82 patients in the 600-mu g group and 21 of the 80 patients in the 900-mu g group met the primary end point. The median urinary free cortisol level decreased by approximately 50% by month 2 and remained stable in both groups. A normal urinary free cortisol level was achieved more frequently in patients with baseline levels not exceeding 5 times the upper limit of the normal range than in patients with higher baseline levels. Serum and salivary cortisol and plasma corticotropin levels decreased, and clinical signs and symptoms of Cushing's disease diminished. Pasireotide was associated with hyperglycemia-related adverse events in 118 of 162 patients; other adverse events were similar to those associated with other somatostatin analogues. Despite declines in cortisol levels, blood glucose and glycated hemoglobin levels increased soon after treatment initiation and then stabilized; treatment with a glucose- lowering medication was initiated in 74 of 162 patients. CONCLUSIONS The significant decrease in cortisol levels in patients with Cushing's disease who received pasireotide supports its potential use as a targeted treatment for corticotropinsecreting pituitary adenomas. (Funded by Novartis Pharma; ClinicalTrials.gov number, NCT00434148.)
Resumo:
The available options for restoring multiple surface cavities are: amalgam, composite resin, or indirect restorations. Adhesive system and intradentinal pin-retained composite resin restorations should have a similar performance to pin-retained amalgam, regarding resistance to support occlusal forces. Polymerization shrinkage is a major concern when performing direct posterior composite resin restorations and the incremental insertion technique can provide less stress and outstanding margin behavior. Intradentinal pins can potentially enhance composite resin's retention, while reducing gaps caused by polymerization shrinkage. This article reports a clinical case involving an extensive restoration on a posterior tooth with cusp loss that was successfully treated using an intradentinal pin and direct nano-hybrid composite resin restoration.
Resumo:
Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.
Resumo:
Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.
Resumo:
OBJECTIVE: To determine the prevalence and independent predictors of significant atherosclerotic renal artery stenosis (RAS) in unselected hypertensive patients undergoing coronary angiography and to assess the 6-month outcome of those patients with a significant RAS. METHODS: One thousand, four hundred and three consecutive hypertensive patients undergoing drive-by renal arteriography were analyzed retrospectively. Univariate and multivariate logistic regression analyses were performed to identify independent predictors of RAS. In patients with significant RAS (>or=50% luminal narrowing), 6-month follow-up was assessed and outcome was compared between patients with or without renal revascularization. RESULTS: The prevalence of significant RAS was 8%. After multivariate analysis, coronary [odds ratio 5.3; 95% confidence interval (CI) 2.7-10.3; P < 0.0001], peripheral (odds ratio 3.3; 95% CI 2.0-5.5; P < 0.0001), and cerebral artery (odds ratio 2.8; 95% CI 1.5-5.3; P = 0.001) diseases, and impaired renal function (odds ratio 2.9; 95% CI 1.8-4.5; P < 0.0001) were found as independent predictors. At least one of these predictors was present in 96% of patients with RAS. In 74 patients (66%) with significant RAS, an ad hoc revascularization was performed. At follow-up, creatinine clearance was significantly higher in revascularized than in nonrevascularized patients (69.2 vs. 55.5 ml/min per 1.73 m, P = 0.029). By contrast, blood pressure was comparable between both groups, but nonrevascularized patients were taking significantly more antihypertensive drugs as compared with baseline (2.7 vs. 2.1, follow-up vs. baseline; P = 0.0066). CONCLUSION: The prevalence of atherosclerotic RAS in unselected hypertensive patients undergoing coronary angiography was low. Coronary, peripheral, and cerebral artery diseases, and impaired renal function were independent predictors of RAS. Ad hoc renal revascularization was associated with better renal function and fewer intake of antihypertensive drugs at follow-up.
Resumo:
The expression of vascular endothelial growth factor (VEGF) is elevated in diabetic macular edema (DME). Ranibizumab binds to and inhibits multiple VEGF variants. We investigated the safety and efficacy of ranibizumab in DME involving the foveal center.
Resumo:
The purpose of this study is to compare the healing of deep, non-contained intrabony defects (i.e., with a ?80% 1-wall component and a residual 2- to 3-wall component in the most apical part) treated with either an enamel matrix derivative (EMD) or guided tissue regeneration (GTR) after 12 months.
Resumo:
This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).
Resumo:
The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.