315 resultados para Meh-ppv
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The 3'-terminal 853 nt (and the putative 283 aa) sequence of the VP2-encoding gene from 29 field strains of porcine parvovirus (PPV) were determined and compared both to each other and with other published sequences. Sequences were examined using maximum-parsimony and statistical analyses for nucleotide diversity and sequence variability. Among the nucleotide sequences of the PPV field strains, 26 polymorphic sites were encountered; 22 polymorphic sites were detected in the putative amino acid sequence. Mapping polymorphic sites of protein data onto the three-dimensional (3D) structure of PPV VP2 revealed that almost all substitutions were located on the external surface of the viral capsid. Mapping amino acid substitutions to the alignment between PPV VP2 sequences and the 3D structure of canine parvovirus (CPV) capsid, many PPV substitutions were observed to map to regions of recognized antigenicity and/or to contain phenotypically important residues for CPV and other parvoviruses. In spite of the high sequence similarity, genetic analysis has shown the existence of at least two virus lineages among the samples. In conclusion, these results highlight the need for close surveillance on PPV genetic drift, with an assessment of its potential ability to modify the antigenic make-up of the virus.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
As atividades que envolvem o uso de explosivos devem ser controladas, não só com relação ao desmonte de estruturas (rocha e outros materiais), mas também quanto a danos estruturais em edificações próximas (casas, edificações históricas, etc.) e outros impactos ambientais como vibração, propagação de ruídos, ultralançamentos e sobrepressão atmosférica. Tais atividades são regidas por normas técnicas que sugerem parâmetros de medição e limites definidos na avaliação de prováveis danos. No caso específico de minerações em áreas urbanas, a velocidade de vibração de partícula (Vp), normalmente expressa em mm/s, é o parâmetro que tem dado melhor correlação na avaliação de possíveis danos às estruturas civis, atribuídos às vibrações do terreno. As diferentes normas existentes apresentam valores de Vp que variam de 2mm/s para edifícios históricos até 150mm/s para construções em concreto armado. A maioria delas considera na avaliação de danos estruturais, além da velocidade, a freqüência da vibração. Algumas normas foram elaboradas com base em dados experimentais, analisando parâmetros como o tipo de construção e o material nela utilizados, outras se basearam apenas em valores empíricos, mas todas apresentam valores conservativos. A norma brasileira não avalia o parâmetro freqüência e não classifica os diferentes tipos de estruturas civis, restringindo-se ao valor resultante da velocidade de vibração como parâmetro medido, sendo, assim, limitada e deficiente em relação às normas internacionais. A coletânea aqui apresentada reuniu as normas nas Américas e em outros continentes, além de uma comparação com as normas européias mais importantes em âmbito mundial.
Resumo:
Alterações anatômicas e fisiológicas da gravidez predispõem gestantes a infecções do trato urinário (ITU). O objetivo deste estudo foi identificar a acurácia do exame de urina simples para diagnóstico de ITU em gestantes de baixo risco. Fez-se uso do estudo de desempenho de teste diagnóstico realizado em Botucatu, SP, com 230 gestantes, entre 2006 e 2008. Os resultados mostram que a prevalência de ITU foi de 10%. A sensibilidade foi 95,6%, especificidade 63,3% e acurácia 66,5% do exame de urina simples, em relação ao diagnóstico de ITU. A análise dos valores preditivos positivo e negativo (VPP e VPN) mostrou que, na vigência de exame de urina simples normal, a chance de haver ITU foi pequena (VPN 99,2%). Frente ao resultado alterado desse exame, a probabilidade de haver ITU foi baixa (VPP 22,4%). Conclui-se que a acurácia do exame de urina simples como meio diagnóstico de ITU foi baixa, sendo indispensável a realização de urocultura para o diagnóstico.
Resumo:
A simple model of electron transfer is adapted to explain fluorescence quenching in self-assembled films of poly( p-phenylene vinylene) (PPV) alternating with poly(thiophene acetic acid) (PTAA). Quenching is caused by a photo-induced electron transfer between the excited PPV (donor, D) and the PTAA (acceptor, A). The electron-transfer process can be mediated by insertion of electronically inert spacing bilayers between the D and A layers, As the number of bilayers is increased, the fluorescence is gradually recovered which is explained theoretically by assuming that the electron-transfer rate can be described as k = Z exp(- beta r) where r is the distance between D and A. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Purpose: To compare the safety and anti-inflammatory efficacy of a single posterior subtenon injection of triamcinolone acetonide (TA) with prednisolone acetate 1% eyedrops after pars plana vitrectomy (PPV).Methods: the study included 40 consecutive phakic eyes of 40 patients undergoing PPV for non-clearing vitreous haemorrhage with attached retina (verified by echography), epiretinal membrane or macular hole. At the end of the surgical procedure, eyes were randomized to receive either a single posterior subtenon injection of TA (40 mg in 1 ml) plus sham eyedrops (prednisolone acetate 1% vehicle) postoperatively (group TA), or a posterior subtenon sham injection (1 ml balanced salt solution) plus prednisolone acetate 1% eyedrops postoperatively (group ED).Results: There was no difference in the severity of anterior chamber cell and flare between the two groups at any time-point during the study period (p > 0.05). Separate within-group analysis revealed a significant decrease in anterior chamber cell and flare from postoperative day 1 to postoperative days 7, 14 and 28 in both groups (p < 0.05). There was no difference in pain, photophobia, conjunctival erythema, ciliary flush or chemosis scores between the two groups at any time-point during the study period (p > 0.05). Steroid-induced intraocular hypertension was not observed in either group.Conclusions: A single posterior subtenon injection of TA can be as effective and safe as a 4-week regimen of prednisolone acetate 1% eyedrops in controlling intraocular inflammation after PPV.
Resumo:
The absorption and luminescence spectra for the poly(p-phenylene vinylene)/sol-gel silica with different thermal treatments were measured. A considerable increase in the luminescence was observed for the polymer introduced into SiO2 matrix with thermal treatment at 120 degreesC. The thermal diffusivity of these samples was measured using the thermal lens technique, and the obtained value 3.3 x 10(-5) cm(2)/s (sample treated at 37 degreesC) is practically independent of the thermal treatment (37-150 degreesC). (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Statistical methods of multiple regression analysis, trend surface analysis and principal components analysis were applied to seismographic data recorded during production blasting at a diabase quarry in the urban area of Campinas (SP), Brazil. The purpose of these analyses was to determine the influence of the following variables: distance (D), charge weight per delay (W), and scaled distance (SD) associated with properties of the rock body (orientation, frequency and angle of geological discontinuities; depth of bedrock and thickness of the soil overburden) in the variation of the peak particle velocity (PPV). This approach yielded variables with larger influences (loads) on the variation of ground vibration, as well as behavior and space tendency of this variation. The results showed a better relationship between PPV and D, with D being the most important factor in the attenuation of the ground vibrations. The geological joints and the depth to bedrock have a larger influence than the explosive charges in the variation of the vibration levels, but frequencies appear to be more influenced by the amount of soil overburden.
Resumo:
STUDY OBJECTIVE: To validate hysteroscopic view with histology in cases of endometrial hyperplasia and cancer in patients with abnormal uterine bleeding (AUB)DESIGN: Retrospective study.(Canadian Task Force classification II-3).SETTING: University teaching hospitals in Rio de Janeiro and São Paulo, and private office in Rio de Janeiro.PATIENTS: Four thousand and fifty-four patients with AUB in whom hysteroscopic views were complete and the histologic result was conclusive.INTERVENTION: Four thousand and fifty-four office hysteroscopies with complete views and conclusive histologic results. The material for histologic examination was obtained through biopsy of the lesion in an outpatient unit or through the resection of the entire lesion in patients who underwent surgery. Histology was considered the gold standard and compared with the hysteroscopic view.MEASUREMENTS AND MAIN RESULTS: In the histology of the 4054 examinations, 613 (15.2%) were endometrial hyperplasia, and 105 (2.6%) were endometrial cancer. The most frequent hysteroscopic finding was endometrial polyps (31.2%). In endometrial hyperplasia, the sensitivity of the hysteroscopic view was 56.3% (95% CI 52.21-60.2%), specificity was 89.1% (95% CI 88.0%-90.1%), positive predictive value (PPV) was 48.0% (95% CI 44.3%-51.7%), negative predictive value (NPV) was 92.0% (95% Cl 90.1%-92.9%), and accuracy was 72.7% (95% CI 70.7%-74.7%). Accuracy was defined as the proportion of correct results among the hysteroscopic examinations. In endometrial cancer, the sensitivity of the hysteroscopic view was 80.0% (95% Cl 71.1%-87.2%), specificity was 99.5% (95% CI 99.2%-99.7%), PPV was 81.5% (95% Cl 72.7%-88.5%), NPV was 99.5% (95% CI 99.2%-99.7%), and accuracy was 89.8% (95% CI, 85.9%-93.6%). In the 814 patients (20.0%) in whom the hysteroscopic view was normal, there were no false negatives for endometrial cancer; however, there were 37 (4.5%) false negatives for endometrial hyperplasia. In the histologic cases of endometrial cancer, 101 (96.2%) hysteroscopic views were compatible with cancer or hyperplasia (80.0% and 16.2%, respectively). Ninety-seven out of 103 hysteroscopic views with cancer findings (94.2%) had histologic diagnosis of cancer or hyperplasia (81.5% and 12.6%, respectively).CONCLUSION: It seems that even in face of good validity of hysteroscopic view for endometrial hyperplasia and cancer, histologic study is mandatory in the presence of any lesion as the hysteroscopic view cannot completely replace the histologic study in patients with AUB. (C) 2006 AAGL. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Poly(p-phenylene vinylene) (PPV) derivatives are well known for their applications in polymer light emitting diodes (PLEDs). These derivatives are highly susceptible to photooxidation though, which is mainly caused by the scission of the vinyl double bond on the polymer backbone. In this work, we show that Langmuir-Blodgett (LB) films are less degraded than cast films of a PPV derivative (OC1OC6-PPV). Both films had similar thickness (∼50 nm) to allow for a more realistic comparison. Photodegradation experiments were carried out by illuminating the films with white light from a halogen lamp (50W, 12 V), placed at a fixed dstance from the sample. The decay was monitored by UV-Vis and FTIR spectroscopies. The results showed that cast films are completely degraded in ca. 300 min, while LB took longer times, ca. 1000 min, i.e. 3 times the values for the cast films. The degradation process occurs in at least two stages, the rates of which were calculated assuming that the reaction follows a first order kinetics. The characteristic times for the first stage were 3.6×10-2 and 1.3×10-3 min-1 for cast and LB films, respectively. For the second stage the characteristic times were 5.6×10-2 and 5.0×10 -3 min-1. The differences can be attributed to the more compact morphology in the LB than in the cast films. With a compact morphology the diffusion of oxygen in the LB film is hampered and this causes a delay in the degradation process.
Resumo:
Aims: To evaluate the reliability of fine needle aspirate cell blocks in the assessment of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins by immunohistochemistry in comparison with surgical specimens. Materials and methods: This is a retrospective study of 62 cases of breast carcinoma diagnosed by fine needle aspiration cytology (FNAC) and confirmed using the surgical specimen. Immunohistochemical tests were performed to assess the presence of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins in cell blocks and the corresponding surgical specimens. The cell block method used alcohol prior to formalin fixation. Cases with 10% or more stained cells were considered positive for ER and PR. Positivity for HER-2/neu was assessed on a scale of 0-3+. The criterion for positivity was a score of 3+. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the cell blocks in the investigation of ER, PR and HER-2/neu protein (3+) were (%): ER, 92.7, 85.7, 92.7, 85.7 and 90.3; PR, 92.7, 94.7, 97.4, 87.0 and 93.5; HER-2/neu, 70.0, 100.0, 100.0, 94.5 and 95.2. Discrepancies were seen in cell blocks in the 1+ and 2+ HER-2/neu staining scores: two of 12 cases scoring 2+ and one case of 26 scoring 1+ on cell blocks scored 3+ on surgical specimens. The correlation index between cell block and corresponding surgical specimen varied from 90% to 94%. Conclusion: Cell blocks provide a useful method of assessing ER, PR and HER-2/neu, mainly for inoperable and recurrent cases, but consideration should be given to carrying out FISH analysis on 1+ as well as 2+ HER-2/neu results. © 2012 Blackwell Publishing Ltd.