919 resultados para Low energy ion scattering
Resumo:
Using a simple effective nucleon-trinucleon interaction we predict and study certain new correlations which are expected to exist between low-energy s-wave spin-isospin singlet observables of the four-nucleon system when various potential models yielding essentially identical two- and three-nucleon observables are employed in four-nucleon calculations. The study of such correlations using different realistic potential models is expected to yield information about the nucleon-nucleon and three-nucleon interactions.
Resumo:
The conventional S-matrix approach to the (tree level) open string low energy effective lagrangian assumes that, in order to obtain all its bosonic alpha'(N) order terms, it is necessary to know the open string (tree level) (N + 2)-point amplitude of massless bosons, at least expanded at that order in alpha'. In this work we clarify that the previous claim is indeed valid for the bosonic open string, but for the supersymmetric one the situation is much more better than that: there are constraints in the kinematical bosonic terms of the amplitude (probably due to Spacetime Supersymmetry) such that a much lower open superstring n-point amplitude is needed to find all the alpha'(N) order terms. In this 'revisited' S-matrix approach we have checked that, at least up to alpha'(4) order, using these kinematical constraints and only the known open superstring 4-point amplitude, it is possible to determine all the bosonic terms of the low energy effective lagrangian. The sort of results that we obtain seem to agree completely with the ones achieved by the method of BPS configurations, proposed about ten years ago. By means of the KLT relations, our results can be mapped to the NS-NS sector of the low energy effective lagrangian of the type II string theories implying that there one can also find kinematical constraints in the N -point amplitudes and that important informations can be inferred, at least up to alpha'(4) order, by only using the (tree level) 4-point amplitude.
Resumo:
We quantize the low-energy sector of a massless scalar field in Reissner-Nordström spacetime. This allows the analysis of processes involving soft scalar particles occurring outside charged black holes. In particular, we compute the response of a static scalar source interacting with Hawking radiation using the Unruh (and the Hartle-Hawking) vacuum. This response is compared with the one obtained when the source is uniformly accelerated in the usual vacuum of Minkowski spacetime with the same proper acceleration. We show that both responses are in general different in opposition to the result obtained when the Reissner-Nordström black hole is replaced by a Schwarzschild one. The conceptual relevance of this result is commented on. ©2000 The American Physical Society.
Resumo:
We study the low-energy universality observed in three-body models through a scale-independent approach. From the already estimated infinite number of three-body excited energy states, which happen in the limit when the energy of the subsystem goes to zero, we are able to identify the lower energies of the helium trimers as possible examples of Thomas-Efimov states. By considering this example, we illustrate the usefulness of a scaling function, which we have defined. The approach is applied to bosonic systems of three identical particles, and also to the case where two kinds of particles are present.
Resumo:
We explore the features of neutrino oscillation which are relevant for measurements of the leptonic CP violating phase δ and the sign of Delta;m13 2 in experiments with low-energy conventional superbeams. Toward the goal, we introduce a new powerful tool called the CP trajectory diagram in bi-probability space which allows us to represent pictorially the three effects, the effects of (a) genuine CP violation due to the sin δ term, (6) CP conserving cos δ term, and (c) fake CP violation due to earth matter, separately in a single diagram. By using the diagram, we observe that there is a two-fold ambiguity in the determination of S which is related with the sign of Delta;m13 2. Possible ways of resolving the ambiguity are discussed. In particular, we point out that an in situ simultaneous measurement of δ and the sign of Delta;m13 2 can be carried out at distances of about 700 km, or at the Phase II of the JHF experiment provided that sin δ ·Delta;m13 2 < 0, both with a megaton class water Cherenkov detector.
Resumo:
SiO2 (1-x) - TiO2 (x) waveguides, with the mole fraction x in the range 0.07 - 0.20 and thickness of about 0.4 μm, were deposited on silica substrates by a dip-coating technique. The thermal treatments at 700-900°C, used to fully densify the xerogels, produce nucleation of TiO2 nanocrystals even for the lowest TiO2 content. The nucleation of TiO2 nanocrystals and their growth by thermal annealing up to 1300°C were studied by waveguide Raman spectroscopy, for the SiO2 (0.8) - TiO2 (0.2) composition. By increasing the annealing temperature, the Raman spectrum evolves from that typical of the silica-titania glass to that of anatase, but brookite phase is dominant at intermediate temperatures. In the low. frequency region (5-50 cm-1) of the Raman spectra, acoustic vibrations of the nanocrystals are observed. From the measured line shapes, we can deduce the size distribution of the particles. The results are compared with those obtained from the line widths in the X-ray diffraction patterns. Nanocrystals with a mean size in the range 4-20 nm are obtained, by thermal annealing in a corresponding range of 800-1300°C.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IFEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.0%. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
PTFE foils were irradiated with different ion beams (Xe, Au and U) with energies up to 1.5 GeV and fluences between 1 x 10(8) and 1 x 10(13) ions/cm(2) at room temperature. The induced modifications in the polymer were analyzed by FTIR, UV-Vis spectroscopy, and XRD. In the FTIR spectra, the CF2 degradation accompanied by the formation of CF3 terminal and side groups were observed. In the UV-Vis spectra, the observed increase in the absorption at UV wavelengths is an indication of polymer carbonization. From XRD, the amorphization of the material was evidenced by the decrease in the intensity of the main diffraction peak. An exponential fit of the intensity of the IR absorption peaks resulted in the following values: 2.9 +/- 0.8; 4.5 +/- 0.9 and 5.6 +/- 0.8 nm for the latent track radius after irradiation with Xe, Au and U beams, respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In the framework of gauged flavour symmetries, new fermions in parity symmetric representations of the standard model are generically needed for the compensation of mixed anomalies. The key point is that their masses are also protected by flavour symmetries and some of them are expected to lie way below the flavour symmetry breaking scale(s), which has to occur many orders of magnitude above the electroweak scale to be compatible with the available data from flavour changing neutral currents and CP violation experiments. We argue that, actually, some of these fermions would plausibly get masses within the LHC range. If they are taken to be heavy quarks and leptons, in (bi)-fundamental representations of the standard model symmetries, their mixings with the light ones are strongly constrained to be very small by electroweak precision data. The alternative chosen here is to exactly forbid such mixings by breaking of flavour symmetries into an exact discrete symmetry, the so-called proton-hexality, primarily suggested to avoid proton decay. As a consequence of the large value needed for the flavour breaking scale, those heavy particles are long-lived and rather appropriate for the current and future searches at the LHC for quasi-stable hadrons and leptons. In fact, the LHC experiments have already started to look for them.
Resumo:
The present work describes the development of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the system started with the characterisation of detectors purchased for this specific task, with the optimisation of the different desired measurement configurations following and ending with the installation and check of the results. A new software has been developed to handle the new detectors.
Resumo:
La tesi nasce da un'attività di ricerca approfondita su alcune tecnologie innovative e all'avanguardia nell'ambito del mobile computing e dell'Internet of Things. Tra queste il focus principale è orientato allo studio del Bluetooth Low Energy, nuova specifica di Bluetooth caratterizzata principalmente da un consumo di energia assai ridotto. In particolare, si è approfondito il suo funzionamento nel caso dei beacon, piccoli dispositivi che permettono una localizzazione mediante l'invio di un segnale BLE. Inoltre è stata analizzata la possibilità di interazione con Android, poiché oggigiorno non si può evitare di pensare a come queste tecnologie possano interfacciarsi con il mondo degli smartphone e dei tablet. Come conseguenza di tale attività di ricerca è stato analizzato un caso di studio che permettesse di applicare le tecnologie studiate e la loro interazione. Si è pensato quindi a un piccolo sistema distribuito per schermi adattativi (capaci di modificare i contenuti visualizzati in relazione ad eventi esterni) affinché ogni schermo mostrasse dinamicamente l'orario delle lezioni di ciascuno studente all'avvicinarsi di quest'ultimo, e solo per il tempo di permanenza nei pressi dello schermo. Si è quindi progettato e sviluppato un prototipo, e infine durante il testing si sono potute verificare le attuali potenzialità di queste tecnologie e trarre conclusioni sulla possibilità della loro futura diffusione e di impiego in contesti differenti.
Resumo:
Lo scopo dell’elaborato di tesi è la progettazione e lo sviluppo di un’applicazione per il modulo Bluetooth Low Energy (BLE) Texas Instrument CC2650 in grado di leggere le informazioni da un sensore analogico, tramite un Analog-Digital- Converter (ADC), e di scambiare i dati con uno smartphone Android in tempo reale. L’interfaccia realizzata deve essere universale, ovvero dovrà essere compatibile con sensori di diverso tipo, facilmente estensibile per l’aggiunta di un numero maggiore di periferiche di lettura e utilizzabile con un ampio numero di dispositivi.
Resumo:
In questo elaborato è stato effettuato uno studio di soluzioni tecnologiche per eseguire una localizzazione di prossimità in ambienti indoor tramite la percezione di segnali Bluetooth Low Energy. Il sistema analizzato e sperimentato è composto da un dispositivo in ricezione che effettua una stima della distanza che intercorre con il trasmettitore, tramite la valutazione della potenza del segnale ricevuto. A causa della propagazione indoor, tale stima risulta poco accurata in termini di ranging in quanto vengono a generarsi delle fluttuazioni istantanee del segnale ricevuto dovute a fenomeni di multipath. L’obiettivo di questo progetto è stato quello di mitigare queste oscillazioni sfruttando due trasmettitori al posto di uno, effettuando quindi in ricezione opportune combinazioni fra i segnali ricevuti (Diversity Combining Techniques).