976 resultados para Low detection limit
Resumo:
The present PhD project was focused on the development of new tools and methods for luminescence-based techniques. In particular, the ultimate goal was to present substantial improvements to the currently available technologies for both research and diagnostic in the fields of biology, proteomics and genomics. Different aspects and problems were investigated, requiring different strategies and approaches. The whole work was thus divided into separate chapters, each based on the study of one specific aspect of luminescence: Chemiluminescence, Fluorescence and Electrochemiluminescence. CHAPTER 1, Chemiluminescence The work on luminol-enhancer solution lead to a new luminol solution formulation with 1 order of magnitude lower detection limit for HRP. This technology was patented with Cyanagen brand and is now sold worldwide for Western Blot and ELISA applications. CHAPTER 2, Fluorescescence The work on dyed-doped silica nanoparticles is marking a new milestone in the development of nanotechnologies for biological applications. While the project is still in progress, preliminary studies on model structures are leading to very promising results. The improved brightness of these nano-sized objects, their simple synthesis and handling, their low toxicity will soon turn them, we strongly believe, into a new generation of fluorescent labels for many applications. CHAPTER 3, Electrochemiluminescence The work on electrochemiluminescence produced interesting results that can potentially turn into great improvements from an analytical point of view. Ru(bpy)3 derivatives were employed both for on-chip microarray (Chapter 3.1) and for microscopic imaging applications (Chapter 3.2). The development of these new techniques is still under investigation, but the obtained results confirm the possibility to achieve the final goal. Furthermore the development of new ECL-active species (Chapter 3.3, 3.4, 3.5) and their use in these applications can significantly improve overall performances, thus helping to spread ECL as powerful analytical tool for routinary techniques. To conclude, the results obtained are of strong value to largely increase the sensitivity of luminescence techniques, thus fulfilling the expectation we had at the beginning of this research work.
Resumo:
For the safety assessments of nuclear waste repositories, the possible migration of the radiotoxic waste into environment must be considered. Since plutonium is the major contribution at the radiotoxicity of spent nuclear waste, it requires special care with respect to its mobilization into the groundwater. Plutonium has one of the most complicated chemistry of all elements. It can coexist in 4 oxidation states parallel in one solution. In this work is shown that in the presence of humic substances it is reduced to the Pu(III) and Pu(IV). This work has the focus on the interaction of Pu(III) with natural occurring compounds (humic substances and clay minerals bzw. Kaolinite), while Pu(IV) was studied in a parallel doctoral work by Banik (in preparation). As plutonium is expected under extreme low concentrations in the environment, very sensitive methods are needed to monitor its presence and for its speciation. Resonance ionization mass spectrometry (RIMS), was used for determining the concentration of Pu in environmental samples, with a detection limit of 106- 107 atoms. For the speciation of plutonium CE-ICP-MS was routinely used to monitor the behaviour of Pu in the presence of humic substances. In order to reduce the detection limits of the speciation methods, the coupling of CE to RIMS was proposed. The first steps have shown that this can be a powerful tool for studies of pu under environmental conditions. Further, the first steps in the coupling of two parallel working detectors (DAD and ICP_MS ) to CE was performed, for the enabling a precise study of the complexation constants of plutonium with humic substances. The redox stabilization of Pu(III) was studied and it was determined that NH2OHHCl can maintain Pu(III) in the reduced form up to pH 5.5 – 6. The complexation constants of Pu(III) with Aldrich humic acid (AHA) were determined at pH 3 and 4. the logß = 6.2 – 6.8 found for these experiments was comparable with the literature. The sorption of Pu(III) onto kaolinite was studied in batch experiments and it was determine dthat the pH edge was at pH ~ 5.5. The speciation of plutonium on the surface of kaolinite was studied by EXAFS/XANES. It was determined that the sorbed species was Pu(IV). The influence of AHA on the sorption of Pu(III) onto kaolinite was also investigated. It was determined that at pH < 5 the adsorption is enhanced by the presence of AHA (25 mg/L), while at pH > 6 the adsorption is strongly impaired (depending also on the adding sequence of the components), leading to a mobilization of plutonium in solution.
Resumo:
Einer der Hauptschwerpunkte der Arbeit lag in der Entwicklung einer spezies-spezifischen und einer spezies-unspezifischen GC-ICP-Q-MSIVA von Schwefelspezies in Petroprodukten. Es wurden hierzu Indikatoren, ausgehend von elementarem 34S-angereichertem Schwefel, im Mikromaßstab synthetisiert. Für die spezies-spezifische GC-ICP-Q-MSIVA wurde die erstmalige Synthese von 34S-markiertem Thiophen, Dibenzothiophen und 4-Methyldibenzothiophen verwirklicht. Als Indikatorsynthese für die spezies-unspezifische GC-ICP-Q-MSIVA erfolgte die erstmalige Darstellung von 34S-angereichertem Dimethyldisulid. Mit Hilfe der synthetisierten Verbindungen wurden spezies-spezifische und spezies-unspezifische massenspektrometrische Isotopenverdünnungsanalysen von Schwefelspezies in Petroprodukten durchgeführt. Vor allen GC-ICP-Q-MSIVA-Analysen erfolgte eine umfangreiche Speziesidentifizierung durch Aufstockexperimente mit kommerziell erhältlichen Standards und mit einem mit der GC gekoppelten Elektronenstoß (EI)-MS. Beide ICP-Q-MS Methoden zeichnen sich durch sehr niedrige Nachweisgrenzen (7 ng S/g) aus, welche auch eine Anwendbarkeit auf tiefentschwefelte Kraftstoffe garantieren. Mit der spezies-unspezifischen GC-ICP-Q-MSIVA ist neben einer Speziesanalyse auch eine Gesamtschwefelanalyse durch Aufsummierung aller in der Probe vorhandenen Spezies möglich. Es wurde im Rahmen dieser Arbeit auch der Einfluss möglicher Empfindlichkeitsänderungen des ICP-Q-MS durch koeluierende Kohlenwasserstoffe überprüft, wobei diese erwartungsgemäß auf das Ergebnis der spezies-spezifischen und spezies-unspezifischen GC-ICP-Q-MSIVA keinerlei Einfluss haben. Der zweite Hauptschwerpunkt der Arbeit lag auf der Ausarbeitung routinefähiger, schneller und zuverlässiger Methoden zur Gesamtelementspurenanalytik von Schwefel und Schwermetallen in Erdölen und Petroprodukten. Für die Gesamtschwefelanalyse wurde eine MSIVA nach thermaler Verdampfung mit 34S-markierten Dibenzothiophen als Indikator entwickelt. Die neu entwickelte Methode erlaubt eine sehr schnelle Bestimmung des Gesamtschwefelgehalts, wobei die eigentliche Messung des Isotopenverhältnisses innerhalb von Sekunden nach der Injektion der Probe erfolgt. Weiterhin zeichnet sich die Methode durch Robustheit und eine niedrige Nachweisgrenze (40 ng S/g) aus. Für die Analyse von Schwermetallen wurden erstmals Möglichkeiten einer direkten MSIVA von Erdölproben ohne zeitraubenden, kontaminationsträchtigen Aufschluss bzw. die schwierige Erzeugung einer Mikroemulsion zwischen hydrophober Probe und wässrigem Indikator entwickelt. Um eine homogene Verteilung des Indikators in der hydrophoben Probe zu ermöglichen, musste ausgehend von den zur Verfügung stehenden wässrigen Indikatorlösungen, eine Überführung des Indikators in ein organisches Lösungsmittel erfolgen. Hierzu wurde der jeweilige Metallindikator unter Komplexierung aus wässrigen Metallindikatorlösungen extrahiert. Für die Analyse der mit diesen Indikatorlösungen in organischer Phase versetzten Proben wurden zwei alternative Methoden ausgearbeitet. Bei der mit der Laserablation (LA) kombinierten ICP-SF-MSIVA wird die isotopenverdünnte Probe aus einer eigens für diesen Zweck entwickelten Probenhalterung ablatiert und so dem ICP-SF-MS zugeführt wird. Bei zeitlich sich verändernden Intensitäten der gemessenen Isotope werden aber reproduzierbare und konstante Isotopenverhältnisse erhalten. Im Falle einer homogenen Verteilung der Metallspuren wurde eine hervorragende Übereinstimmung mit Vergleichsmethoden und einem Referenzmaterial festgestellt. Im Falle einer heterogenen partikulären Verteilung der Metallspuren, wie sie z.B. bei Eisenspuren in den Erdölen vorlag, ist die Anwendbarkeit der LA-ICP-SF-MSIVA aufgrund des kleinen Probenvolumens (20 µL) jedoch begrenzt. Als Alternative zur LA-ICP-SF-MSIVA wurde ein System unter Verwendung der Fließinjektion für die Zuführung der isotopenverdünnten Probe zum ICP-SF-MS ausgearbeitet. Die isotopenverdünnte Probe wird hierbei in einen Eluentenstrom von Toluol injiziert und mit Hilfe einer Total-Consumption-Zerstäuber/Sprühkammer-Einheit vollständig bei einer Flussrate von 10 µL/min in das Plasma eingebracht. Neben einer nochmaligen Verkürzung der Analysenzeit und Vereinfachung der Probenvorbereitung bietet diese Methode zusätzlich stark verbesserte Nachweisgrenzen (z.B. Ni 0,9 ng/g). Leider sind mit diesem Verfahren bis jetzt nur Ni und Mo zuverlässig bestimmbar. Das in dieser Arbeit ausgearbeitete Methodenpaket erlaubt erstmals eine breite Einführung der ICP-MSIVA als zuverlässige Methode in die Routineanalytik der Petroindustrie. Durch die bewiesene Zuverlässigkeit, den geringen Zeitaufwand und die Robustheit der Methoden steht ihrem routinemäßigen Einsatz, außer einer weitergehenderen Automatisierung einzelner Verfahrensteile, prinzipiell nichts entgegen.
Resumo:
In der vorliegenden Arbeit werden Entwicklungen zur Optimierung von Selektivität und Effizienz von Resonanzionisations-Laserionenquellen vorgestellt. Mit der Perspektive auf die Anwendungen radioaktiver Ionenstrahlen in der Grundlagenforschung sowie auf Fragestellungen in der Ultraspurenanalytik wurden verschiedene Methoden entwickelt und erprobt: Auf Seiten der Grundlagenforschung wurden zwei komplementäre Ansätze, die Konstruktion von Ionenquellen aus Materialien niedriger Austrittsarbeit und die Weiterentwicklung der Laserionenquelle und -falle LIST umgesetzt. Hierdurch konnte die Selektivität der Resonanzionisation in on-line Tests um einige Gröÿenordnungen verbessert werden. Für die Ultraspurenanalytik wurden speziell angepasste, hocheffiziente Ionenquellen entwickelt. Mit diesen Ionenquellen wurde für die Resonanzionisation von Gallium eine Ionisationseffizienz von 67 % demonstriert, für den Ultraspurennachweis des im Zusammenhang der nuklearen Endlagerung wichtigen Radioisotops 99g-Technetium wurde auf dieser Grundlage eine Nachweisgrenze von weniger als 10^6 Atomen gezeigt.
Resumo:
In dieser Arbeit wurde die Methode der resonanten Ionisation von neutralen Atomen mittels Laserstrahlung auf die leichten Aktinide Thorium, Uran, Neptunium und Plutonium angewendet und für die Ultraspurenanalyse optimiert. Der empfindliche Nachweis dieser Aktinide stellt eine Herausforderung für die Beobachtung und Bestimmung von radioaktiven Verunreinigungen aus kerntechnischen Anlagen in der Umwelt dar. In einem für diese Untersuchungen entwickelten Quadrupolmassenspektrometer konnte durch Resonanzionisationsspektroskopie jeweils eine Reihe unbekannter Energiezustände in der Elektronenhülle des neutralen Atoms der oben genannten Aktinide identifiziert, sowie effiziente Anregungsschemata für die resonante Ionisation entwickelt und charakterisiert werden. Durch die verwendete in-source-Ionisation, die aufgrund der guten Überlagerung von Laserstrahlung und Atomstrahl eine hohe Nachweiseffizienz gewährleistet, konnten diese Untersuchungen bereits mit einem, für Radionuklide notwendigen, geringen Probeneintrag erfolgen. Die resonante Ionisation erlaubt durch die selektiven resonanten Prozesse eine Unterdrückung unerwünschter Kontaminationen und wurde auf den analytischen Nachweis von Ultraspurengehalten in Umweltproben, sowie die Bestimmung der entsprechenden Isotopenzusammensetzung optimiert. Durch die effiziente in-source-Ionisation mit leistungsstarker gepulster Laserstrahlung, konnten Nachweiseffizienzen im Bereich von bis zu 1% erreicht werden. Dabei wurden für Plutonium in synthetischen Proben, aber auch in ersten Umweltproben, Nachweisgrenzen von 10^4-10^5 Atomen erzielt. Die Verwendung spektral schmalbandiger Dauerstrichlaser und eine Ionisation transversal zum frei propagierenden Atomstrahl ermöglicht durch Auflösung der Isotopieverschiebung eine hohe Selektivität gegenüber dominanten Nachbarisotopen, wohingegen die Ionisationseffizienz deutlich abnimmt. Hiermit konnte für das Ultraspurenisotop U-236 eine Nachweisgrenze bis hinab zu 10^-9 für das Isotopenverhältnis N(U-236)/N(U-238) bestimmt werden.
Resumo:
Flüchtige organische Bestandteile (engl.: VOC) sind in der Atmosphäre in Spuren vorhanden, spielen aber trotzdem eine wichtige Rolle in der Luftchemie: sie beeinflussen das Ozon der Troposphäre, städtischen Smog, Oxidationskapazität und haben direkte und indirekte Auswirkungen auf die globale Klimaveränderung. Eine wichtige Klasse der VOC sind die Nicht-Methan-Kohlenwasserstoffe (engl.: NMHC), die überwiegend von anthropogenen Quellen kommen. Aus diesem Grund ist für Luftchemiker ein Messinstrument nötig, das die VOC, die NMHC eingeschlossen, mit einer höheren Zeitauflösung misst, besonders für Echtzeitmessungen an Bord eines Forschungsflugzeuges. Dafür wurde das System zur schnellen Beobachtung von organischen Spuren (engl.: FOTOS) entworfen, gebaut für den Einsatz in einem neuen Wissenschaftlichen Flugzeug, das in großen Höhen und über weite Strecken fliegt, genannt HALO. In der Folge wurde FOTOS in zwei Messkampagnen am Boden getestet. FOTOS wurde entworfen und gebaut mit einem speziell angefertigten, automatisierten, kryogenen Probensystem mit drei Fallen und einem angepassten, erworbenen schnellen GC-MS. Ziel dieses Aufbaus war es, die Vielseitigkeit zu vergrößern und das Störungspotential zu verringern, deshalb wurden keine chemischen Trocknungsmittel oder adsorbierenden Stoffe verwendet. FOTOS erreichte eine Probenfrequenz von 5.5 Minuten, während es mindestens 13 verschiedene C2- bis C5-NMHC maß. Die Drei-Sigma-Detektionsgrenze für n- und iso-Pentan wurde als 2.6 und 2.0 pptv ermittelt, in dieser Reihenfolge. Labortests bestätigten, dass FOTOS ein vielseitiges, robustes, hochautomatisiertes, präzises, genaues, empfindliches Instrument ist, geeignet für Echtzeitmessungen von VOC in Probenfrequenzen, die angemessen sind für ein Forschungsflugzeug wie HALO. Um die Leistung von FOTOS zu bestätigen, wurde vom 26. Januar bis 4. Februar 2010 ein Zwischenvergleich gemacht mit dem GC-FID-System am Meteorologischen Observatorium Hohenpeißenberg, einer WMO-GAW-globalen Station. Dreizehn verschiedene NMHC wurden innerhalb des Rahmens der GWA Data Quality Objectives (DQO) analysiert und verglichen. Mehr als 80% der Messungen von sechs C3- bis C5-NMHC erfüllten diese DQO. Diese erste Messkampagne im Feld hob die Robustheit und Messgenauigkeit von FOTOS hervor, zusätzlich zu dem Vorteil der höheren Probenfrequenz, sogar in einer Messung am Boden. Um die Möglichkeiten dieses Instrumentes im Feld zu zeigen, maß FOTOS ausgewählte leichte NMHC während einer Messkampagne im Borealen Waldgebiet, HUMPPA-COPEC 2010. Vom 12. Juli bis zum 12. August 2010 beteiligte sich eine internationale Gruppe von Instituten und Instrumenten an Messungen physikalischer und chemischer Größen der Gas- und Partikelphasen der Luft über dem Borealen Wald an der SMEAR II-Station nahe Hyyttiälä, Finnland. Es wurden mehrere Hauptpunkte von Interesse im Mischungsverhältnis der Alkane und im Isomerenverhätnis von Pentan identifiziert, insbesondere sehr unterschiedliche Perioden niedriger und hoher Variabilität, drei Rauchschwaden von Biomassen-Verbrennung von russischen Waldbränden und zwei Tage mit extrem sauberer Luft aus der Polarregion. Vergleiche der NMHC mit anderen anthropogenen Indikatoren zeigten mehrere Quellen anthropogener Einflüsse am Ort auf und erlaubten eine Unterscheidung zwischen lokalen und weiter entfernten Quellen. Auf einen minimalen natürlichen Beitrag zum 24h-Kreislauf von NOx wurde geschlussfolgert aus der Korrelation von NOx mit Alkanen. Altersschätzungen der Luftmassen durch das Isomerenverhältnis von Pentan wurden erschwert durch sich verändernde Verhältnisse der Quellen und durch Besonderheiten der Photochemie während des Sommers im hohen Norden. Diese Messungen zeigten den Wert des Messens leichter NMHC, selbst in abgelegenen Regionen, als einen zusätzlichen spezifischen Marker von anthropogenem Einfluss.
Resumo:
Zusammenfassung rnIn der vorliegenden Arbeit wurden sechs VWF/FVIII Gerinnungsfaktorkonzentrate unterschiedlicher Chargen auf ihre ADAMTS13 Aktivität, Antigen und VWF Multimere untersucht. Grund dafür ist die Annahme, dass bei der Aufkonzentrierung des VWFs möglicherweise auch erhöhte Mengen an ADAMTS13 vorhanden sind. Wäre dies nachweisbar, könnten die entsprechenden Konzentrate auch Anwendung bei TTP Patienten finden. Neben den Gerinnungsfaktorkonzentraten wurden ebenfalls die zur Plasmapherese verwendeten Therapeutika FFP und s/d Plasma analysiert. Es soll getestet werden, ob Unterschiede hinsichtlich der Qualität zwischen den Präparaten bestehen und inwiefern die Blutgruppen eine Auswirkung auf die ADAMTS13 Aktivität/Antigen haben. Überdies wurde die Bedeutung von ADAMTS13 als wichtiges diagnostisches Merkmal im Rahmen der Gegenüberstellung von Patienten mit thrombotischen Mikroangiopathien erörtert. Alle angewandten Methoden wurden zudem kritisch miteinander verglichen und auf ihre Eignung für die klinische Diagnostik getestet. Zur Untersuchung der ADAMTS13 Aktivität kamen drei unterschiedliche Methoden zur Anwendung, die BCS-Methode nach Böhm und zwei FRET Kits (Technozym®ADAMTS13/ActifluorTMADAMTS13). Für die Bestimmung des ADAMTS13 Antigen wurde das Technozym®ADAMTS13 Kit verwendete als auch der Imubind®ELISA angewendet. Mittels der SDS-Gelelektrophorese konnten die VWF Multimere dargestellt werden. Die Untersuchungen konnten zeigen, dass nur in Haemate®P, deutlich höhere ADAMTS13 Aktivitäten (12,3% bzw. 470ng/ml) sowie ein physiologische Antigenwerte vorlagen. Die anderen Faktorkonzentrate wiesen entweder nur sehr geringe bzw. keine Aktivitäten auf. Das Antigen lag bei allen Konzentraten im nachweisbaren Bereich. Folglich ist ein Einsatz von Haemate®P bei der Therapie der TTP, insbesondere bei hereditären Formen sowie bei Kindern, die durch eine Plasmapherese stark belastet werden, und bei Schwangeren, könnten, in Erwägung zu ziehen und innerhalb der Klinik zu testen. Die Plasmapräparate FFP und Octaplas® wiesen in allen Untersuchungen ADAMTS13 Aktivitäten und Antigen im mittleren bis hohen physiologischen Bereich auf. Insbesondere bei Blutgruppe 0 ließ sich beiden Präparaten eine höhere ADAMTS13 Aktivität und Antigen gegenüber den drei anderen Blutgruppen darstellen. Insgesamt waren die interindividuellen Schwankungen bei FFP deutlich höher als bei Octaplas®, was sich in der unterschiedlichen Herstellung der Präparate begründen lässt. Octaplas® ist also genauso geeignet zur Plasmapherese bei der TTP wie FFP, kann jedoch aufgrund seiner intensiveren Virusinaktivierung eine größere Sicherheit aufweisen und stellt sich auch in der Klinik als nebenwirkungsärmer dar. Bei der Gegenüberstellung der thrombotischen Mikroangiopathien konnte gezeigt werden, dass eine verminderte ADAMTS13 Aktivität ein wichtiges Unterscheidungsmerkmal ist und auch während der Remission schon diagnostizierbar werden kann. Auf der Grundlage der labordiagnostischen Werte und dem klinischen Erscheinungsbild im akuten Schub und in der Remission konnte ein diagnostischer Algorithmus für den klinischen Alltag erstellt werden. In der Methodenvalidierung erwies sich der ActifluorTMADAMTS13 Kit als der beste Kit, da er innerhalb kürzester Zeit zuverlässige Werte in Standardeinheiten liefert. Nach neuesten Erkenntnissen, bei der eine Unterscheidung von ADAMTS13 Aktivitäten über und unter 5 % von großer prognostischer Bedeutung sind, ist die BCS-Methode nach Böhm mit einer unteren Nachweisgrenze von 6,2% zu ungenau und auch hinsichtlich ihres Zeitaufwandes eher ungünstig.rn
Resumo:
This thesis focused on the polymer’s influence on the interaction of polymeric NPs with epithelial cells. Furthermore, the measurement of single submicron nanoparticles in a commercially available flow cytometer was established, to provide a new method in the toolbox for nanoparticle-cell studies. This gave way to develop a routine for the absolute quantification of intracellular NPs via flow cytometry. rnThe cellular uptake of poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(L-lactide) (PLLA) nanoparticles was investigated via flow cytometry. PLLA-NPs were internalized the most efficiently. But upon co-incubation of PS and PLLA particles with cells, the two particles mutually influenced their uptake, slightly shifting the relative uptake efficiencies. This phenomenon should be based on specific properties of the different polymer materials. The findings indicated a competition (which is strongly influenced by properties of the respective polymeric material) for the uptake into the cells, allegedly due to competition for specific coatings with serum components that enhances the NPs’ cellular uptake. The fluorescence of single 150 nm particles was determined with a benchtop cytometer, breaching the machine’s detection limit but yielding precise NP fluorescence standardization factors. Up to now, these standardization factors are mostly determined by spectroscopic analysis of the particles’ dye content. Finally a flow cytometric routine for absolute particle counting in cells was devised. This quantitation revealed a low uptake efficiency for un-functionalized PMMA NPs of less than 150 NPs (approx. 0,001 % of added) per cell.rn
Resumo:
Die Erdatmosphäre besteht hauptsächlich aus Stickstoff (78%), Sauerstoff (21%) und Edelga¬sen. Obwohl Partikel weniger als 0,1% ausmachen, spielen sie eine entscheidende Rolle in der Chemie und Physik der Atmosphäre, da sie das Klima der Erde sowohl direkt als auch indirekt beeinflussen. Je nach Art der Bildung unterscheidet man zwischen primären und sekundären Partikeln, wobei primäre Partikel direkt in die Atmosphäre eingetragen werden. Sekundäre Partikel hingegen entstehen durch Kondensation von schwerflüchtigen Verbindungen aus der Gasphase, welche durch Reaktionen von gasförmigen Vorläufersubstanzen (volatile organic compounds, VOCs) mit atmosphärischen Oxidantien wie Ozon oder OH-Radikalen gebildet werden. Da die meisten Vorläufersubstanzen organischer Natur sind, wird das daraus gebil¬dete Aerosol als sekundäres organisches Aerosol (SOA) bezeichnet. Anders als die meisten primären Partikel stammen die VOCs überwiegend aus biogenen Quellen. Es handelt sich da¬bei um ungesättigte Kohlenwasserstoffe, die bei intensiver Sonneneinstrahlung und hohen Temperaturen von Pflanzen emittiert werden. Viele der leichtflüchtigen Vorläufersubstanzen sind chiral, sowohl die Vorläufer als auch die daraus gebildeten Partikel werden aber in den meisten Studien als eine Verbindung betrachtet und gemeinsam analysiert. Die mit Modellen berechneten SOA-Konzentrationen, welche auf dieser traditionellen Vorstellung der SOA-Bil¬dung beruhen, liegen deutlich unterhalb der in der Atmosphäre gefundenen, so dass neben diesem Bildungsweg auch noch andere SOA-Bildungsarten existieren müssen. Aus diesem Grund wird der Fokus der heutigen Forschung vermehrt auf die heterogene Chemie in der Partikelphase gerichtet. Glyoxal als Modellsubstanz kommt hierbei eine wichtige Rolle zu. Es handelt sich bei dieser Verbindung um ein Molekül mit einem hohen Dampfdruck, das auf Grund dieser Eigenschaft nur in der Gasphase zu finden sein sollte. Da es aber über zwei Alde¬hydgruppen verfügt, ist es sehr gut wasserlöslich und kann dadurch in die Partikelphase über¬gehen, wo es heterogenen chemischen Prozessen unterliegt. Unter anderem werden in An¬wesenheit von Ammoniumionen Imidazole gebildet, welche wegen der beiden Stickstoff-He¬teroatome lichtabsorbierende Eigenschaften besitzen. Die Verteilung von Glyoxal zwischen der Gas- und der Partikelphase wird durch das Henrysche Gesetz beschrieben, wobei die Gleichgewichtskonstante die sogenannte Henry-Konstante ist. Diese ist abhängig von der un¬tersuchten organischen Verbindung und den im Partikel vorhandenen anorganischen Salzen. Für die Untersuchung chiraler Verbindungen im SOA wurde zunächst eine Filterextraktions¬methode entwickelt und die erhaltenen Proben anschließend mittels chiraler Hochleistungs-Flüssigchromatographie, welche an ein Elektrospray-Massenspektrometer gekoppelt war, analysiert. Der Fokus lag hierbei auf dem am häufigsten emittierten Monoterpen α-Pinen und seinem Hauptprodukt, der Pinsäure. Da bei der Ozonolyse des α-Pinens das cyclische Grund¬gerüst erhalten bleibt, können trotz der beiden im Molekül vorhanden chiralen Zentren nur zwei Pinsäure Enantiomere gebildet werden. Als Extraktionsmittel wurde eine Mischung aus Methanol/Wasser 9/1 gewählt, mit welcher Extraktionseffizienzen von 65% für Pinsäure Enan¬tiomer 1 und 68% für Pinsäure Enantiomer 2 erreicht werden konnten. Des Weiteren wurden Experimente in einer Atmosphärensimulationskammer durchgeführt, um die Produkte der α-Pinen Ozonolyse eindeutig zu charakterisieren. Enantiomer 1 wurde demnach aus (+)-α-Pinen gebildet und Enantiomer 2 entstand aus (-)-α-Pinen. Auf Filterproben aus dem brasilianischen Regenwald konnte ausschließlich Pinsäure Enantiomer 2 gefunden werden. Enantiomer 1 lag dauerhaft unterhalb der Nachweisgrenze von 18,27 ng/mL. Im borealen Nadelwald war das Verhältnis umgekehrt und Pinsäure Enantiomer 1 überwog vor Pinsäure Enantiomer 2. Das Verhältnis betrug 56% Enantiomer 1 zu 44% Enantiomer 2. Saisonale Verläufe im tropischen Regenwald zeigten, dass die Konzentrationen zur Trockenzeit im August höher waren als wäh¬rend der Regenzeit im Februar. Auch im borealen Nadelwald wurden im Sommer höhere Kon¬zentrationen gemessen als im Winter. Die Verhältnisse der Enantiomere änderten sich nicht im jahreszeitlichen Verlauf. Die Bestimmung der Henry-Konstanten von Glyoxal bei verschiedenen Saataerosolen, nämlich Ammoniumsulfat, Natriumnitrat, Kaliumsulfat, Natriumchlorid und Ammoniumnitrat sowie die irreversible Produktbildung aus Glyoxal in Anwesenheit von Ammoniak waren Forschungs¬gegenstand einer Atmosphärensimulationskammer-Kampagne am Paul-Scherrer-Institut in Villigen, Schweiz. Hierzu wurde zunächst das zu untersuchende Saataerosol in der Kammer vorgelegt und dann aus photochemisch erzeugten OH-Radikalen und Acetylen Glyoxal er¬zeugt. Für die Bestimmung der Glyoxalkonzentration im Kammeraerosol wurde zunächst eine beste¬hende Filterextraktionsmethode modifiziert und die Analyse mittels hochauflösender Mas¬senspektrometrie realisiert. Als Extraktionsmittel kam 100% Acetonitril, ACN zum Einsatz wo¬bei die Extraktionseffizienz bei 85% lag. Für die anschließende Derivatisierung wurde 2,4-Di¬nitrophenylhydrazin, DNPH verwendet. Dieses musste zuvor drei Mal mittels Festphasenex¬traktion gereinigt werden um störende Blindwerte ausreichend zu minimieren. Die gefunde¬nen Henry-Konstanten für Ammoniumsulfat als Saataerosol stimmten gut mit in der Literatur gefundenen Werten überein. Die Werte für Natriumnitrat und Natriumchlorid als Saataerosol waren kleiner als die von Ammoniumsulfat aber größer als der Wert von reinem Wasser. Für Ammoniumnitrat und Kaliumsulfat konnten keine Konstanten berechnet werden. Alle drei Saataerosole führten zu einem „Salting-in“. Das bedeutet, dass bei Erhöhung der Salzmolalität auch die Glyoxalkonzentration im Partikel stieg. Diese Beobachtungen sind auch in der Litera¬tur beschrieben, wobei die Ergebnisse dort nicht auf der Durchführung von Kammerexperi¬menten beruhen, sondern mittels bulk-Experimenten generiert wurden. Für die Trennung der Imidazole wurde eine neue Filterextraktionsmethode entwickelt, wobei sich ein Gemisch aus mit HCl angesäuertem ACN/H2O im Verhältnis 9/1 als optimales Extrak¬tionsmittel herausstellte. Drei verschiedenen Imidazole konnten mit dieser Methode quanti¬fiziert werden, nämlich 1-H-Imidazol-4-carbaldehyd (IC), Imidazol (IM) und 2,2‘-Biimidazol (BI). Die Effizienzen lagen für BI bei 95%, für IC bei 58% und für IM bei 75%. Kammerexperimente unter Zugabe von Ammoniak zeigten höhere Imidazolkonzentrationen als solche ohne. Wurden die Experimente ohne Ammoniak in Anwesenheit von Ammoni¬umsulfat durchgeführt, wurden höhere Imidazol-Konzentrationen gefunden als ohne Ammo¬niumionen. Auch die relative Luftfeuchtigkeit spielte eine wichtige Rolle, da sowohl eine zu hohe als auch eine zu niedrige relative Luftfeuchtigkeit zu einer verminderten Imidazolbildung führte. Durch mit 13C-markiertem Kohlenstoff durchgeführte Experimente konnte eindeutig gezeigt werden, dass es sich bei den gebildeten Imidazolen und Glyoxalprodukte handelte. Außerdem konnte der in der Literatur beschriebene Bildungsmechanismus erfolgreich weiter¬entwickelt werden. Während der CYPHEX Kampagne in Zypern konnten erstmalig Imidazole in Feldproben nach¬gewiesen werden. Das Hauptprodukt IC zeigte einen tageszeitlichen Verlauf mit höheren Kon¬zentrationen während der Nacht und korrelierte signifikant aber schwach mit der Acidität und Ammoniumionenkonzentration des gefundenen Aerosols.
Resumo:
Two alpacas from a herd in southwest Switzerland died for unknown reasons. Necropsy revealed chronic weight loss and pale mucous membranes. Infection with hemotropic mycoplasmas was suspected and subsequently confirmed by molecular methods. In order to investigate the epidemiological situation in this herd, a real-time TaqMan((R)) qPCR assay for the specific detection and quantification of hemoplasma infection in South American camelids was developed. This assay was based on the 16S rRNA gene and amplified 'Candidatus Mycoplasma haemolamae' DNA, but not DNA from other hemoplasmas or non-hemotropic mycoplasma species. The lower detection limit was one copy/PCR, and the amplification efficiency was 97.4%. In 11 out of 24 clinically healthy herd mates of the two infected alpacas, 'Candidatus M. haemolamae' infection was confirmed. No correlation was found between bacterial load and clinical signs or anemia. The assay described herein enables to detect and quantify 'Candidatus M. haemolamae' and may be used in future studies to investigate the prevalence, pathogenesis and treatment follow-up of hemoplasma infections in South American camelids.
Resumo:
A continuous and highly sensitive absorption method for detection of soluble phosphate in ice cores has been developed using a molybdate reagent and a 2m liquid waveg- uide (LWCC). The method is optimized to meet the low concentrations of phosphate in Greenland ice, it has a detection limit of around 0.1ppb and a depth resolution of approximately 2cm. The new method has been applied to obtain phosphate concen- trations from segments of two Northern Greenland ice cores: from a shallow firn core covering the most recent 120yr and from the recently obtained deep NEEM ice core in which sections from the late glacial period have been analysed. Phosphate con- centrations in 20th century ice are around 0.32ppb with no indication of anthropogenic influence in the most recent ice. In the glacial part of the NEEM ice core concentra- tions in the cold stadial periods are significantly higher, in the range of 6–24ppb, while interstadial ice concentrations are around 2ppb. In the shallow firn core, a strong cor- relation between concentrations of phosphate and insoluble dust suggests a similar deposition pattern for phosphate and dust. In the glacial ice, phosphate and dust also correlate quite strongly, however it is most likely that this correlation originates from the phosphate binding to dust during transport, with only a fraction coming directly from dust. Additionally a constant ratio between phosphate and potassium concentrations shows evidence of a possible biogenic land source.
Resumo:
Currently, observations of space debris are primarily performed with ground-based sensors. These sensors have a detection limit at some centimetres diameter for objects in Low Earth Orbit (LEO) and at about two decimetres diameter for objects in Geostationary Orbit (GEO). The few space-based debris observations stem mainly from in-situ measurements and from the analysis of returned spacecraft surfaces. Both provide information about mostly sub-millimetre-sized debris particles. As a consequence the population of centimetre- and millimetre-sized debris objects remains poorly understood. The development, validation and improvement of debris reference models drive the need for measurements covering the whole diameter range. In 2003 the European Space Agency (ESA) initiated a study entitled “Space-Based Optical Observation of Space Debris”. The first tasks of the study were to define user requirements and to develop an observation strategy for a space-based instrument capable of observing uncatalogued millimetre-sized debris objects. Only passive optical observations were considered, focussing on mission concepts for the LEO, and GEO regions respectively. Starting from the requirements and the observation strategy, an instrument system architecture and an associated operations concept have been elaborated. The instrument system architecture covers the telescope, camera and onboard processing electronics. The proposed telescope is a folded Schmidt design, characterised by a 20 cm aperture and a large field of view of 6°. The camera design is based on the use of either a frame-transfer charge coupled device (CCD), or on a cooled hybrid sensor with fast read-out. A four megapixel sensor is foreseen. For the onboard processing, a scalable architecture has been selected. Performance simulations have been executed for the system as designed, focussing on the orbit determination of observed debris particles, and on the analysis of the object detection algorithms. In this paper we present some of the main results of the study. A short overview of the user requirements and observation strategy is given. The architectural design of the instrument is discussed, and the main tradeoffs are outlined. An insight into the results of the performance simulations is provided.
Resumo:
The identification of 15N-labeled 3-nitrotyrosine (NTyr) by gas chromatography/mass spectroscopy in protein hydrolyzates from activated RAW 264.7 macrophages incubated with 15N-L-arginine confirms that nitric oxide synthase (NOS) is involved in the nitration of protein-bound tyrosine (Tyr). An assay is presented for NTyr that employs HPLC with tandem electrochemical and UV detection. The assay involves enzymatic hydrolysis of protein, acetylation, solvent extraction, O-deacetylation, and dithionite reduction to produce an analyte containing N-acetyl-3-aminotyrosine, an electrochemically active derivative of NTyr. We estimate the level of protein-bound NTyr in normal rat plasma to be approximately 0-1 residues per 10(6) Tyr with a detection limit of 0.5 per 10(7) Tyr when > 100 nmol of Tyr is analyzed and when precautions are taken to limit nitration artifacts. Zymosan-treated RAW 264.7 cells were shown to have an approximately 6-fold higher level of protein-bound NTyr compared with control cells and cells treated with N(G)-monomethyl-L-arginine, an inhibitor of NOS. Intraperitoneal injection of F344 rats with zymosan led to a marked elevation in protein-bound NTyr to approximately 13 residues per 10(6) Tyr, an approximately 40-fold elevation compared with plasma protein of untreated rats; cotreatment with N(G)-monomethyl-L-arginine inhibited the formation of NTyr in plasma protein from blood and peritoneal exudate by 69% and 53%, respectively. This assay offers a highly sensitive and quantitative approach for investigating the role of reactive byproducts of nitric oxide in the many pathological conditions and disease states associated with NO(X) exposure such as inflammation and smoking.
Resumo:
BACKGROUND: Culture-independent methods based on the 16S ribosomal RNA molecule are nowadays widely used for assessment of the composition of the intestinal microbiota, in relation to host health or probiotic efficacy. Because Bifidobacterium thermophilum was only recently isolated from human faeces until now, no specific real-time PCR (qPCR) assay has been developed for detection of this species as component of the bifidobacterial community of the human intestinal flora. RESULTS: Design of specific primers and probe was achieved based on comparison of 108 published bifidobacterial 16S rDNA sequences with the recently published sequence of the human faecal isolate B. thermophilum RBL67. Specificity of the primer was tested in silico by similarity search against the sequence database and confirmed experimentally by PCR amplification on 17 Bifidobacterium strains, representing 12 different species, and two Lactobacillus strains. The qPCR assay developed was linear for B. thermophilum RBL67 DNA quantities ranging from 0.02 ng/microl to 200 ng/microl and showed a detection limit of 10(5) cells per gram faeces. The application of this new qPCR assay allowed to detect the presence of B. thermophilum in one sample from a 6-month old breast-fed baby among 17 human faecal samples tested. Additionally, the specific qPCR primers in combination with selective plating experiments led to the isolation of F9K9, a faecal isolate from a 4-month old breast-fed baby. The 16S rDNA sequence of this isolate is 99.93% similar to that of B. thermophilum RBL67 and confirmed the applicability of the new qPCR assay in faecal samples. CONCLUSION: A new B. thermophilum-specific qPCR assay was developed based on species-specific target nucleotides in the 16S rDNA. It can be used to further characterize the composition of the bifidobacterial community in the human gastrointestinal tract. Until recently, B. thermophilum was considered as a species of animal origin, but here we confirm with the application of this new PCR assay the presence of B. thermophilum strains in the human gut.
Resumo:
BODIPY (4,4-Difluoro-3a,4a-diaza-s-indacene) dyes have gained lots of attention in application of fluorescence sensing and imaging in recent years because they possess many distinctive and desirable properties such as high extinction coefficient, narrow absorption and emission bands, high quantum yield and low photobleaching effect. However, most of BODIPY-based fluorescent probes have very poor solubilities in aqueous solution, emit less than 650 nm fluorescence that can cause cell and tissue photodamages compared with bio-desirable near infrared (650-900 nm) light. These undesirable properties extremely limit the applications of BODIPY-based fluorescent probes in sensing and imaging applications. In order to overcome these drawbacks, we have developed a very effective strategy to prepare a series of neutral highly water- soluble BODIPY dyes by enhancing the water solubilities of BODIPY dyes via incorporation of tri(ethylene glycol)methyl ether (TEG) and branched oligo(ethylene glycol)methyl ether (BEG) residues onto BODIPY dyes at 1,7-, 2,6-, 3,5-, 4- and meso- positions. We also have effectively tuned absorptions and emissions of BOIDPY dyes to red, deep red and near infrared regions via significant extension of π-conjugation of BODIPY dyes by condensation reactions of aromatic aldehydes with 2,6-diformyl BODIPY dyes at 1,3,5,7-positions. Based on the foundation that we built for enhancing water solubility and tuning wavelength, we have designed and developed a series of water-soluble, BODIPY-based fluorescent probes for sensitive and selective sensing and imaging of cyanide, Zn (II) ions, lysosomal pH and cancer cells. We have developed three BODIPY-based fluorescent probes for sensing of cyanide ions by incorporating indolium moieties onto the 6-position of TEG- or BEG-modified BOIDPY dyes. Two of them are highly water-soluble. These fluorescent probes showed selective and fast ratiometric fluorescent responses to cyanide ions with a dramatic fluorescence color change from red to green accompanying a significant increase in fluorescent intensity. The detection limit was measured as 0.5 mM of cyanide ions. We also have prepared three highly water-soluble fluorescent probes for sensing of Zn (II) ions by introducing dipicoylamine (DPA, Zn ion chelator) onto 2- and/or 6-positions of BEG-modified BODIPY dyes. These probes showed selective and sensitive responses to Zn (II) ion in the range from 0.5 mM to 24 mM in aqueous solution at pH 7.0. Particularly, one of the probes displayed ratiometric responses to Zn (II) ions with fluorescence quenching at 661 nm and fluorescence enhancement at 521 nm. This probe has been successfully applied to the detection of intracellular Zn (II) ions inside the living cells. Then, we have further developed three acidotropic, near infrared emissive BODIPY- based fluorescent probes for detection of lysosomal pH by incorporating piperazine moiety at 3,5-positions of TEG- or BEG-modified BODIPY dyes as parts of conjugation. The probes have low auto-fluorescence at physiological neutral condition while their fluorescence intensities will significant increase at 715 nm when pH shift to acidic condition. These three probes have been successfully applied to the in vitro imaging of lysosomes inside two types of living cells. At the end, we have synthesized one water- soluble, near infrared emissive cancer cell targetable BODIPY-based fluorescent polymer bearing cancer homing peptide (cRGD) residues for cancer cell imaging applications. This polymer exhibited excellent water-solubility, near infrared emission (712 nm), good biocompatibility. It also showed low nonspecific interactions to normal endothelial cells and can effectively detect breast tumor cells.