993 resultados para Laser intensity dependence


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Developments in laser technology over the past few years have made it possible to do experiments with focused intensities of IO"-102' Wcm'z. Short-pulse high-intensity lasers are able to accelerate protons and heavier ions to multi-MeV energies during their interaction with solid targets, gas jets and clusters. When such a laser radiation is focused at the intensity above 10” Wcm'2, local electric field strength will be almost equivalent to that within an atom. Hence, new nonlinear optical phenomena will be expected in the field of light matter interaction. Most of the research in the material interaction using high power lasers, especially related to plasma interaction, has been directed to the short pulse x-ray generation- Nanosecond laser interactions with solid targets also generate plasmas which emit radiation mainly in the optical region, the understanding of which is far from satisfactory. This thesis deals with a detailed study of some of the dynamical processes in plasmas generated by nanosecond and femtosecond lasers

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many nonlinear optical microscopy techniques based on the high-intensity nonlinear phenomena were developed recent years. A new technique based on the minimal-invasive in-situ analysis of the specific bound elements in biological samples is described in the present work. The imaging-mode Laser-Induced Breakdown Spectroscopy (LIBS) is proposed as a combination of LIBS, femtosecond laser material processing and microscopy. The Calcium distribution in the peripheral cell wall of the sunflower seedling (Helianthus Annuus L.) stem is studied as a first application of the imaging-mode LIBS. At first, several nonlinear optical microscopy techniques are overviewed. The spatial resolution of the imaging-mode LIBS microscope is discussed basing on the Point-Spread Function (PSF) concept. The primary processes of the Laser-Induced Breakdown (LIB) are overviewed. We consider ionization, breakdown, plasma formation and ablation processes. Water with defined Calcium salt concentration is used as a model of the biological object in the preliminary experiments. The transient LIB spectra are measured and analysed for both nanosecond and femtosecond laser excitation. The experiment on the local Calcium concentration measurements in the peripheral cell wall of the sunflower seedling stem employing nanosecond LIBS shows, that nanosecond laser is not a suitable excitation source for the biological applications. In case of the nanosecond laser the ablation craters have random shape and depth over 20 µm. The analysis of the femtosecond laser ablation craters shows the reproducible circle form. At 3.5 µJ laser pulse energy the diameter of the crater is 4 µm and depth 140 nm for single laser pulse, which results in 1 femtoliter analytical volume. The experimental result of the 2 dimensional and surface sectioning of the bound Calcium concentrations is presented in the work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the developement of an chemically stable and easy to produce in situ sensor for fast and reliable detection of polycyclic aromatic hydrocarbons (PAH) in low nanomolar concentrations. Metallic nanoparticles on dielectric substrates werde used for the rst time with surface enhanced Raman spectroscopy (SERS) in combination with shifted excitation Raman difference spectroscopy (SERDS). The preparation of the metallic nanoparticle ensembles with Volmer-Webergrowth is described first. The nanoparticles are characterized with both, optical spectroscopy and atomic force microscopy. The morphological properties of the nanoparticle ensembles are de ned by the mean axial ratio (a/b) and the mean equivalent radius (R Äq), respectively. The prepared and characterized nanoparticles were then used for intensive Raman spectroscopy measurements. Two sophisticated diode laser systems were used in cooperation with the TU Berlin, to carry out these experiments. The first step was to establish the ideal combination of excitation wavelength of the diode laser and the maximum of the surface plasmon resonance of the nanoparticle ensembles. From these results it was deduced, that for an optimum Raman signal the plasmon resonance maximum of the nanoparticle ensemble has to be red-shifted a few nanometeres in respect to the excitation wavelength. Different PAHs werde detected in concentrations of only 2 and 0.5 nmol/, respectively. Furthermore, the obtained results show an excellent reproducability. In addition the time dependence of the Raman signal intensity was investigated. The results of these measurements show, that only 2 minutes after placing the substrates in the molecular solution, a detectable Raman signal was generated. The maximum Raman signal, i.e. the time in which the molecular adsorption process is finished, was determined to about 10 minutes. In summary it was shown, that the used metallic nanoparticle ensembles are highly usable as substrates for SERS in combination with SERDS to detect PAHs in low nanomolar concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die laserinduzierte Plasmaspektroskopie (LIPS) ist eine spektrochemische Elementanalyse zur Bestimmung der atomaren Zusammensetzung einer beliebigen Probe. Für die Analyse ist keine spezielle Probenpräparation nötig und kann unter atmosphärischen Bedingungen an Proben in jedem Aggregatzustand durchgeführt werden. Femtosekunden Laserpulse bieten die Vorteile einer präzisen Ablation mit geringem thermischen Schaden sowie einer hohen Reproduzierbarkeit. Damit ist fs-LIPS ein vielversprechendes Werkzeug für die Mikroanalyse technischer Proben, insbesondere zur Untersuchung ihres Ermüdungsverhaltens. Dabei ist interessant, wie sich die initiierten Mikrorisse innerhalb der materialspezifschen Struktur ausbreiten. In der vorliegenden Arbeit sollte daher ein schnelles und einfach zu handhabendes 3D-Rasterabbildungsverfahren zur Untersuchung der Rissausbreitung in TiAl, einer neuen Legierungsklasse, entwickelt werden. Dazu wurde fs-LIPS (30 fs, 785 nm) mit einem modifizierten Mikroskopaufbau (Objektiv: 50x/NA 0.5) kombiniert, welcher eine präzise, automatisierte Probenpositionierung ermöglicht. Spektrochemische Sensitivität und räumliches Auflösungsvermögen wurden in energieabhängigen Einzel- und Multipulsexperimenten untersucht. 10 Laserpulse pro Position mit einer Pulsenergie von je 100 nJ führten in TiAl zum bestmöglichen Kompromiss aus hohem S/N-Verhältnis von 10:1 und kleinen Lochstrukturen mit inneren Durchmessern von 1.4 µm. Die für das Verfahren entscheidende laterale Auflösung, dem minimalen Lochabstand bei konstantem LIPS-Signal, beträgt mit den obigen Parametern 2 µm und ist die bislang höchste bekannte Auflösung einer auf fs-LIPS basierenden Mikro-/Mapping-Analyse im Fernfeld. Fs-LIPS Scans von Teststrukturen sowie Mikrorissen in TiAl demonstrieren eine spektrochemische Sensitivität von 3 %. Scans in Tiefenrichtung erzielen mit denselben Parametern eine axiale Auflösung von 1 µm. Um die spektrochemische Sensitivität von fs-LIPS zu erhöhen und ein besseres Verständnis für die physikalischen Prozesse während der Laserablation zu erhalten, wurde in Pump-Probe-Experimenten untersucht, in wieweit fs-Doppelpulse den laserinduzierten Abtrag sowie die Plasmaemission beeinflussen. Dazu wurden in einem Mach-Zehnder-Interferometer Pulsabstände von 100 fs bis 2 ns realisiert, Gesamtenergie und Intensitätsverhältnis beider Pulse variiert sowie der Einfluss der Materialparameter untersucht. Sowohl das LIPS-Signal als auch die Lochstrukturen zeigen eine Abhängigkeit von der Verzögerungszeit. Diese wurden in vier verschiedene Regimes eingeteilt und den physikalischen Prozessen während der Laserablation zugeordnet: Die Thermalisierung des Elektronensystems für Pulsabstände unter 1 ps, Schmelzprozesse zwischen 1 und 10 ps, der Beginn des Abtrags nach mehreren 10 ps und die Expansion der Plasmawolke nach über 100 ps. Dabei wird das LIPS-Signal effizient verstärkt und bei 800 ps maximal. Die Lochdurchmesser ändern sich als Funktion des Pulsabstands wenig im Vergleich zur Tiefe. Die gesamte Abtragsrate variiert um maximal 50 %, während sich das LIPS-Signal vervielfacht: Für Ti und TiAl typischerweise um das Dreifache, für Al um das 10-fache. Die gemessenen Transienten zeigen eine hohe Reproduzierbarkeit, jedoch kaum eine Energie- bzw. materialspezifische Abhängigkeit. Mit diesen Ergebnissen wurde eine gezielte Optimierung der DP-LIPS-Parameter an Al durchgeführt: Bei einem Pulsabstand von 800 ps und einer Gesamtenergie von 65 nJ (vierfach über der Ablationsschwelle) wurde eine 40-fache Signalerhöhung bei geringerem Rauschen erzielt. Die Lochdurchmesser vergrößerten sich dabei um 44 % auf (650±150) nm, die Lochtiefe um das Doppelte auf (100±15) nm. Damit war es möglich, die spektrochemische Sensitivität von fs-LIPS zu erhöhen und gleichzeitig die hohe räumliche Auflösung aufrecht zu erhalten.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis, a dual mode tunable gas sensor based on intracavity laser absorption spectroscopy (ICLAS) principle is investigated, both, numerically and experimentally. In order to minimize the cost and size of the gas sensor, relative intensity noise (RIN) is implemented as a detection parameter. Investigation is performed to determine the effect of injection current, operating temperature, mode spacing, and cavity length on RIN. It has been found that it is best to operate the gas sensor at smaller mode spacing and near the threshold current or at larger mode spacing and far above the threshold current for the use of RIN as the readout parameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Uniformly distributed ZnO nanorods with diameter 70-100 nm and 1-2μm long have been successfully grown at low temperatures on GaN by using the inexpensive aqueous solution method. The formation of the ZnO nanorods and the growth parameters are controlled by reactant concentration, temperature and pH. No catalyst is required. The XRD studies show that the ZnO nanorods are single crystals and that they grow along the c axis of the crystal plane. The room temperature photoluminescence measurements have shown ultraviolet peaks at 388nm with high intensity, which are comparable to those found in high quality ZnO films. The mechanism of the nanorod growth in the aqueous solution is proposed. The dependence of the ZnO nanorods on the growth parameters was also investigated. While changing the growth temperature from 60°C to 150°C, the morphology of the ZnO nanorods changed from sharp tip (needle shape) to flat tip (rod shape). These kinds of structure are useful in laser and field emission application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Uniformly distributed ZnO nanorods with diameter 80-120 nm and 1-2µm long have been successfully grown at low temperatures on GaN by using the inexpensive aqueous solution method. The formation of the ZnO nanorods and the growth parameters are controlled by reactant concentration, temperature and pH. No catalyst is required. The XRD studies show that the ZnO nanorods are single crystals and that they grow along the c axis of the crystal plane. The room temperature photoluminescence measurements have shown ultraviolet peaks at 388nm with high intensity, which are comparable to those found in high quality ZnO films. The mechanism of the nanorod growth in the aqueous solution is proposed. The dependence of the ZnO nanorods on the growth parameters was also investigated. While changing the growth temperature from 60°C to 150°C, the morphology of the ZnO nanorods changed from sharp tip with high aspect ratio to flat tip with smaller aspect ratio. These kinds of structure are useful in laser and field emission application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the results of GaInNAs/GaAs quantum dot structures with GaAsN barrier layers grown by solid source molecular beam epitaxy. Extension of the emission wavelength of GaInNAs quantum dots by ~170nm was observed in samples with GaAsN barriers in place of GaAs. However, optimization of the GaAsN barrier layer thickness is necessary to avoid degradation in luminescence intensity and structural property of the GaInNAs dots. Lasers with GaInNAs quantum dots as active layer were fabricated and room-temperature continuous-wave lasing was observed for the first time. Lasing occurs via the ground state at ~1.2μm, with threshold current density of 2.1kA/cm[superscript 2] and maximum output power of 16mW. These results are significantly better than previously reported values for this quantum-dot system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IntraCavity Laser Absorption Spectroscopy (ICLAS) is a high-resolution, high sensitivity spectroscopic method capable of measuring line positions, linewidths, lineshapes, and absolute line intensities with a sensitivity that far exceeds that of a traditional multiple pass absorption cell or Fourier Transform spectrometer. From the fundamental knowledge obtained through these measurements, information about the underlying spectroscopy, dynamics, and kinetics of the species interrogated can be derived. The construction of an ICLA Spectrometer will be detailed, and the measurements utilizing ICLAS will be discussed, as well as the theory of operation and modifications of the experimental apparatus. Results include: i) Line intensities and collision-broadening coefficients of the A band of oxygen and previously unobserved, high J, rotational transitions of the A band, hot-band transitions, and transitions of isotopically substituted species. ii) High-resolution (0.013 cm-1) spectra of the second overtone of the OH stretch of trans-nitrous acid recorded between 10,230 and 10,350 cm-1. The spectra were analyzed to yield a complete set of rotational parameters and an absolute band intensity, and two groups of anharmonic perturbations were observed and analyzed. These findings are discussed in the context of the contribution of overtone-mediated processes to OH radical production in the lower atmosphere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accuracy of a 3D reconstruction using laser scanners is significantly determined by the detection of the laser stripe. Since the energy pattern of such a stripe corresponds to a Gaussian profile, it makes sense to detect the point of maximum light intensity (or peak) by computing the zero-crossing point of the first derivative of such Gaussian profile. However, because noise is present in every physical process, such as electronic image formation, it is not sensitive to perform the derivative of the image of the stripe in almost any situation, unless a previous filtering stage is done. Considering that stripe scanning is an inherently row-parallel process, every row of a given image must be processed independently in order to compute its corresponding peak position in the row. This paper reports on the use of digital filtering techniques in order to cope with the scanning of different surfaces with different optical properties and different noise levels, leading to the proposal of a more accurate numerical peak detector, even at very low signal-to-noise ratios

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coral growth rate can be affected by environmental parameters such as seawater temperature, depth, and light intensity. The natural reef environment is also disturbed by human influences such as anthropogenic pollutants, which in Barbados are released close to the reefs. Here we describe a relatively new method of assessing the history of pollution and explain how these effects have influenced the coral communities off the west coast of Barbados. We evaluate the relative impact of both anthropogenic pollutants and natural stresses. Sclerochronology documents framework and skeletal growth rate and records pollution history (recorded as reduced growth) for a suite of sampled Montastraea annularis coral cores. X-radiography shows annual growth band patterns of the corals extending back over several decades and indicates significantly lower growth rate in polluted sites. Results using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) on the whole sample (aragonite, organic matter, trapped particulate matter, etc.), have shown contrasting concentrations of the trace elements (Cu, Sn, Zn, and Pb) between corals at different locations and within a single coral. Deepwater corals 7 km apart, record different levels of Pb and Sn, suggesting that a current transported the metal pollution in the water. In addition, the 1995 hurricanes are associated with anomalous values for Sn and Cu from most sites. These are believed to result from dispersion of nearshore polluted water. We compared the concentrations of trace elements in the coral growth of particular years to those in the relevant contemporaneous seawater. Mean values for the concentration factor in the coral, relative to the water, ranged from 10 for Cu and Ni to 2.4 and 0.7 for Cd and Zn, respectively. Although the uncertainties are large (60-80%), the coral record enabled us to demonstrate the possibility of calculating a history of seawater pollution for these elements from the 1940s to 1997. Our values were much higher than those obtained from analysis of carefully cleaned coral aragonite; they demonstrate the incorporation of more contamination including that from particulate material as well as dissolved metals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-resolved kinetic studies of the reaction of dideutero-silylene, SiD2, generated by laser flash photolysis of phenylsilane-d(3), have been carried out to obtain rate constants for its bimolecular reaction with C2H2. The reaction was studied in the gas phase over the pressure range 1-100 Torr in SF6 bath gas, at five temperatures in the range 297-600 K. The second-order rate constants obtained by extrapolation to the high-pressure limits at each temperature fitted the Arrhenius equation log(k(infinity)/cm(3) molecule(-1) s(-1)) = (-10.05 +/- 0.05) + (3.43 +/- 0.36 kJ mol(-1))/RT ln 10. The rate constants were used to obtain a comprehensive set of isotope effects by comparison with earlier obtained rate constants for the reactions of SiH2 with C2H2 and C2D2. Additionally, pressure-dependent rate constants for the reaction of SiH2 with C2H2 in the presence of He (1-100 Tort) were obtained at 300, 399, and 613 K. Quantum chemical (ab initio) calculations of the SiC2H4 reaction system at the G3 level support the initial formation of silirene, which rapidly isomerizes to ethynylsilane as the major pathway. Reversible formation of vinylsilylene is also an important process. The calculations also indicate the involvement of several other intermediates, not previously suggested in the mechanism. RRKM calculations are in semiquantitative agreement with the pressure dependences and isotope effects suggested by the ab initio calculations, but residual discrepancies suggest the possible involvement of the minor reaction channel, SiH2 + C2H2 - SWPO + C2H4. The results are compared and contrasted with previous studies of this reaction system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present an application of cavity-enhanced absorption spectroscopy with an off-axis alignment of the cavity formed by two spherical mirrors and with time integration of the cavity-output intensity for detection of nitrogen dioxide (NO2) and iodine monoxide (IO) radicals using a violet laser diode at lambda = 404.278 nm. A noise-equivalent (1sigma = root-mean-square variation of the signal) fractional absorption for one optical pass of 4.5x10(-8) was demonstrated with a mirror reflectivity of similar to0.99925, a cavity length of 0.22 m and a lock-in-amplifier time constant of 3 s. Noise-equivalent detection sensitivities towards nitrogen dioxide of 1.8x10(10) molecule cm(-3) and towards the IO radical of 3.3x10(9) molecule cm(-3) were achieved in flow tubes with an inner diameter of 4 cm for a lock-in-amplifier time constant of 3 s. Alkyl peroxy radicals were detected using chemical titration with excess nitric oxide (RO2 + NO --> RO + NO2). Measurement of oxygen-atom concentrations was accomplished by determining the depletion of NO2 in the reaction NO2 + O --> NO + O-2. Noise-equivalent concentrations of alkyl peroxy radicals and oxygen atoms were 3x10(10) molecule cm(-3) in the discharge-flow-tube experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Our objective was to test the performance of CA125 in classifying serum samples from a cohort of malignant and benign ovarian cancers and age-matched healthy controls and to assess whether combining information from matrix-assisted laser desorption/ionization (MALDI) time-of-flight profiling could improve diagnostic performance. Materials and Methods: Serum samples from women with ovarian neoplasms and healthy volunteers were subjected to CA125 assay and MALDI time-of-flight mass spectrometry (MS) profiling. Models were built from training data sets using discriminatory MALDI MS peaks in combination with CA125 values and tested their ability to classify blinded test samples. These were compared with models using CA125 threshold levels from 193 patients with ovarian cancer, 290 with benign neoplasm, and 2236 postmenopausal healthy controls. Results: Using a CA125 cutoff of 30 U/mL, an overall sensitivity of 94.8% (96.6% specificity) was obtained when comparing malignancies versus healthy postmenopausal controls, whereas a cutoff of 65 U/mL provided a sensitivity of 83.9% (99.6% specificity). High classification accuracies were obtained for early-stage cancers (93.5% sensitivity). Reasons for high accuracies include recruitment bias, restriction to postmenopausal women, and inclusion of only primary invasive epithelial ovarian cancer cases. The combination of MS profiling information with CA125 did not significantly improve the specificity/accuracy compared with classifications on the basis of CA125 alone. Conclusions: We report unexpectedly good performance of serum CA125 using threshold classification in discriminating healthy controls and women with benign masses from those with invasive ovarian cancer. This highlights the dependence of diagnostic tests on the characteristics of the study population and the crucial need for authors to provide sufficient relevant details to allow comparison. Our study also shows that MS profiling information adds little to diagnostic accuracy. This finding is in contrast with other reports and shows the limitations of serum MS profiling for biomarker discovery and as a diagnostic tool

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-resolved kinetic studies of the reactions of silylene, SiH2, and dideutero-silylene, SiD2, generated by laser. ash photolysis of phenylsilane and phenylsilane-d(3), respectively, have been carried out to obtain rate coefficients for their bimolecular reactions with 2-butyne, CH3C CCH3. The reactions were studied in the gas phase over the pressure range 1-100 Torr in SF6 bath gas at five temperatures in the range 294-612 K. The second-order rate coefficients, obtained by extrapolation to the high pressure limits at each temperature, fitted the Arrhenius equations where the error limits are single standard deviations: log(k(H)(infinity)/cm(3) molecule(-1) s(-1)) = (-9.67 +/- 0.04) + (1.71 +/- 0.33) kJ mol(-1)/RTln10 log(k(D)(infinity)/cm(3) molecule(-1) s(-1)) = (-9.65 +/- 0.01) + (1.92 +/- 0.13) kJ mol(-1)/RTln10 Additionally, pressure-dependent rate coefficients for the reaction of SiH2 with 2-butyne in the presence of He (1-100 Torr) were obtained at 301, 429 and 613 K. Quantum chemical (ab initio) calculations of the SiC4H8 reaction system at the G3 level support the formation of 2,3-dimethylsilirene [cyclo-SiH2C(CH3)=C(CH3)-] as the sole end product. However, reversible formation of 2,3-dimethylvinylsilylene [CH3CH=C(CH3)SiH] is also an important process. The calculations also indicate the probable involvement of several other intermediates, and possible products. RRKM calculations are in reasonable agreement with the pressure dependences at an enthalpy value for 2,3-dimethylsilirene fairly close to that suggested by the ab initio calculations. The experimental isotope effects deviate significantly from those predicted by RRKM theory. The differences can be explained by an isotopic scrambling mechanism, involving H - D exchange between the hydrogens of the methyl groups and the D-atoms in the ring in 2,3-dimethylsilirene-1,1-d(2). A detailed mechanism involving several intermediate species, which is consistent with the G3 energy surface, is proposed to account for this.