923 resultados para Landfill gases
Resumo:
The Beckman Helium Discharge Detector has been found to be sensitive to the fixed gases oxygen, nitrogen, and hydrogen at detection levels 10-100 times more sensitive than possible with a Bow-Mac Thermal Conductivity Detector. Detection levels o~ approximately 1.9 E-4 ~ v/v oxygen, 3.1 E-4 ~ v/v nitrogen, and 3.0 E-3 ~ v/v hydrogen are estimated. Response of the Helium Discharge Detector was not linear, but is useable for quantitation over limited ranges of concentration using suitably prepared working standards. Cleanliness of the detector discharge electrodes and purity of the helium carrier and discharge gas were found to be critical to the operation of the detector. Higher sensitivities of the Helium Discharge Detector may be possible by the design and installation of a sensitive, solid-state electrometer.
Resumo:
This study examined the impact of habitat restoration on bee communities (Hymenoptera: Apidae) of the Niagara Region, Ontario, Canada. Bee abundance and diversity was studied in three restored landfill sites: the Glenridge Quarry Naturalization Site (GQNS) in St. Catharines, Elm Street Naturalization Site in Port Colborne, and Station Road Naturalization Site in Wainfleet during 2011 and 2012. GQNS represented older sites restored from 2001-2003. Elm and Station sites represented newly restored landfills as of 2011. These sites were compared to control sites at Brock University where bee communities are well established and again to other landfills where no stable habitat was available before restoration. The objective of this study is to investigate the impact of restoration level on bee abundance and diversity in restored landfill sites of the Niagara Region. Based on the increased disturbance hypothesis (InDH) and the intermediate disturbance hypothesis (IDH), I hypothesized that bee abundance and diversity will follow two patterns. First pattern according to InDH suggest that as the disturbance decrease the bee abundance and diversity will increased. Second pattern according to the IDH bee abundance and diversity will be the highest at the intermediate level of disturbance. A total of 7 173 bees were collected using pan traps and flower collections, from May to October 2011 and 2012. Bees were classified to five families, 21 genera and sub-genera, containing at least 78 species. In 2011 bee abundance was not significantly different among restoration levels while in 2012 bee abundance was significant difference among restoration level. According to family there were no significant difference in Halictidae and Apidae abundance among restoration level while Colletidae and Megachilidae abundance were varied among restoration levels. The bee species richness was highest in the newly restored sites followed by restored control sites, and then the control site. The current study demonstrates that habitat restoration results in rapid increases in bee abundance and diversity for newly restored sites, and, further, that it takes only 2-3 years for bee assemblages in newly restored sites to arrive at the same levels of abundance and diversity as in nearby control sites where bee communities are well established.
Resumo:
Tesis (Maestría en Ciencias con Especialidad en Química Analítica Biomédica) UANL
Resumo:
Tesis (Maestría en la Enseñanza de la Ciencia con Especialidad en Química) UANL
Resumo:
Tesis (Maestría en Ciencias en Producción Agrícola) UANL
Resumo:
Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Térmica y Fluidos - Universidad Autónoma de Nuevo León, 1999
Resumo:
Tesis (Maestro en Ciencias de la Ingeniería Eléctrica con Especialidad en Control) UANL, 2000.
Resumo:
Tesis (Maestría en Ciencias Químicas con Especialidad en Química Analítica) U.A.N.L.
Resumo:
UANL
Resumo:
Tesis (Doctorado en Ciencias Agrícolas con Especialidad en Agua-Suelo) UANL
Resumo:
Tesis (Doctor en Ciencias con Acentuación en Alimentos) UANL, 2010.
Resumo:
One of the main challenges in the development of metal-oxide gas sensors is enhancement of selectivity to a particular gas. Currently, two general approaches exist for enhancing the selective properties of sensors. The first one is aimed at preparing a material that is specifically sensitive to one compound and has low or zero cross-sensitivity to other compounds that may be present in the working atmosphere. To do this, the optimal temperature, doping elements, and their concentrations are investigated. Nonetheless, it is usually very difficult to achieve an absolutely selective metal oxide gas sensor in practice. Another approach is based on the preparation of materials for discrimination between several analyte in a mixture. It is impossible to do this by using one sensor signal. Therefore, it is usually done either by modulation of sensor temperature or by using sensor arrays. The present work focus on the characterization of n-type semiconducting metal oxides like Tungsten oxide (WO3), Zinc Oxide (ZnO) and Indium oxide (In2O3) for the gas sensing purpose. For the purpose of gas sensing thick as well as thin films were fabricated. Two different gases, NO2 and H2S gases were selected in order to study the gas sensing behaviour of these metal oxides. To study the problem associated with selectivity the metal oxides were doped with metals and the gas sensing characteristics were investigated. The present thesis is entitled “Development of semiconductor metal oxide gas sensors for the detection of NO2 and H2S gases” and consists of six chapters.
Resumo:
Leachate from an untreated landfill or landfill with damaged liners will cause the pollution of soil and ground water. Here an attempt was made to generate knowledge on concentrations of all relevant pollutants in soil due to municipal solid waste landfill leachate and its migration through soil and also to study the effect of leachate on the engineering properties of soil. To identify the pollutants in soil due to the leachate generated from municipal solid waste landfill site, a case study on an unlined municipal solid waste landfill at Kalamassery has been done. Soil samples as well as water samples were collected from the site and analysed to identify the pollutants and its effect on soil characteristics. The major chemicals in the soil were identified as Ammonia, Chloride, Nitrate, Iron, Nickel, Chromium, Cadmium etc.. Engineering properties of field soil samples show that the chemicals from the leachate of landfill may have effect on the engineering properties of soil. Laboratory experiments were formulated to model the field around an unlined MSW landfill using two different soils subjected to a synthetic leachate. The Maximum change in chemical concentration and engineering property was observed on soil samples at a radial distance of 0.2 m and at a depth of 0.3 m. The pollutant (chemicals) transport pattern through the soil was also studied using synthetic leachate. To establish the effect of pollutants (chemicals) on engineering properties of soil, experiments were conducted on two types soils treated with the synthetic chemicals at four different concentrations. Analyses were conducted after maturing periods of 7, 50, 100 and 150 days. Test soils treated with maximum chemical concentration and matured for 150 days were showing major change in the properties. To visualize the flow of pollutants through soil in a broader sense, the transportation of pollutants through soil was modeled using software ‘Visual MODFLOW’. The actual field data collected for the case study was used to calibrate the modelling and thus simulated the flow pattern of the pollutants through soil around Kalamassery municipal solid waste landfill for an extent of 4 km2. Flow was analysed for a time span of 30 years in which the landfill was closed after 20 years. The concentration of leachate beneath the landfill was observed to be reduced considerably within one year after closure of landfill and within 8 years, it gets lowered to a negligible level. As an environmensstal management measure to control the pollution through leachate, permeable reactive barriers are used as an emerging technology. Here the suitability of locally available materials like coir pith, rice husk and sugar cane bagasse were investigated as reactive media in permeable reactive barrier. The test results illustrates that, among these, coir pith was showing better performance with maximum percentage reduction in concentration of the filtrate. All these three agricultural wastes can be effectively utilized as a reactive material. This research establishes the influence of leachate of municipal solid waste landfill on the engineering properties of soil. The factors such as type of the soil, composition of leachate, infiltration rate, aquifers, ground water table etc., will have a major role on the area of influence zone of the pollutants in a landfill. Software models of the landfill area can be used to predict the extent and the time span of pollution of a landfill, by inputting the accurate field parameters and leachate characteristics. The present study throws light on the role of agro waste materials on the reduction of the pollution in leachate and thus prevents the groundwater and soil from contamination
Resumo:
Se desconoce en la actualidad en Colombia la calidad de la interpretación de los gases arteriales por parte de los residentes de medicina de emergencias. Los gases arteriales es una de las ayudas diagnósticas de más rápida consecución en el servicio de urgencias y más utilizadas por ser indispensable en la valoración de patologías de alta prevalencia como son las enfermedades respiratorias y la sepsis. Su mala interpretación puede llevar a mal direccionamiento del manejo de pacientes en estado crítico por lo que es indefectible que los residentes logren un buen entrenamiento en la interpretación de los mismos. Por esta razón se realiza este estudio analítico de concordancia con recolección prospectiva, de corte transversal que busca determinar el grado de concordancia en la interpretación de gases arteriales de los residentes del programa de Medicina de Emergencias de la Universidad del Rosario y especialista en cuidado crítico, así como la interpretación entre ellos según su nivel de entrenamiento y describir cuáles son los hallazgos que encuentran en la interpretación de los mismos. Se recolectaron 60 gases arteriales realizados a paciente hospitalizados en la unidad de cuidados intensivos de la Fundación Santa Fe de Bogotá y se halló la concordancia entre la lectura de los residentes del programa de Medicina de Emergencias y un intensivista. Encontrando una concordancia moderada (r 0.445 y 0.442, ) en las respuestas identificadas en los residentes de segundo y tercer año de residencia(p:0,000y0,01).(MESH: Blood Gas Análisis, Emergency Medical Services, Education, Medical, Graduate)