207 resultados para Lamps


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Harley & Ellington, architects. W.E. Wood Co., contractor. Built from July 1940 to January 1942. Built jointly for the Engineering Society of Detroit and the University as an Extension Service facility in Detroit. Funded by the Horace H. and Mary A. Rackham Fund. Sculptures on exterior by Marshall Fredericks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Harley & Ellington, architects. W.E. Wood Co., contractor. Built from July 1940 to January 1942. Built jointly for the Engineering Society of Detroit and the University as an Extension Service facility in Detroit. Funded by the Horace H. and Mary A. Rackham Fund. Sculptures on exterior by Marshall Fredericks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Harley & Ellington, architects. W.E. Wood Co., contractor. Built from July 1940 to January 1942. Built jointly for the Engineering Society of Detroit and the University as an Extension Service facility in Detroit. Funded by the Horace H. and Mary A. Rackham Fund. Sculptures on exterior by Marshall Fredericks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To optimize anterior eye fluorescein viewing and image capture. Design: Prospective experimental investigation. Methods: The spectral radiance of ten different models of slit-lamp blue luminance and the spectral transmission of three barrier filters were measured. Optimal clinical instillation of fluorescein was evaluated by a comparison of four different instillation methods of fluorescein into 10 subjects. Two methods used a floret, and two used minims of different concentration. The resulting fluorescence was evaluated for quenching effects and efficiency over time. Results: Spectral radiance of the blue illumination typically had an average peak at 460 nm. Comparison between three slit-lamps of the same model showed a similar spectral radiance distribution. Of the slit-lamps examined, 8.3% to 50.6% of the illumination output was optimized for >80% fluorescein excitation, and 1.2% to 23.5% of the illumination overlapped with that emitted by the fluorophore. The barrier filters had an average cut-off at 510 to 520 nm. Quenching was observed for all methods of fluorescein instillation. The moistened floret and the 1% minim reached a useful level of fluorescence in on average ∼20s (∼2.5× faster than the saturated floret and 2% minim) and this lasted for ∼160 seconds. Conclusions: Most slit-lamps' blue light and yellow barrier filters are not optimal for fluorescein viewing and capture. Instillation of fluorescein using a moistened floret or 1% minim seems most clinically appropriate as lower quantities and concentrations of fluorescein improve the efficiency of clinical examination. © 2006 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate colour vision testing requires using the correct illumination. With the plethora of 'daylight' lamps available, is there a cost-effective alternative to the discontinued MacBeth Easel lamp? Smoking is a known risk factor for macula degeneration. As the macula is responsible for colour discrimination, any toxin that affects it has the potential to influence colour discrimination. Aims: To find a costeffective light source for colour vision testing. To investigate the effect of smoking on colour discrimination. To explore how deuteranomalous trichromats compare with normal trichromats. Methods: Using the Ishihara colour vision test subjects were classified into the groups: 'Normal/Control', 'Smoker/Test', and 'Case Study' (subjects who failed the screening test and did not smoke). They completed the Farnsworth Munsell 100 Hue test under each of the three light sources: Phillips EcoHalo Twist (tungsten halogen - THL), Kosnic KCF07ALU/GU10-865 (compact fluorescent- CFL), and Deal Guardian Ltd. GU103X2WA4B-60 (light-emitting diode - LED) Results: 42 subjects took part in the study: 18 in the Normal/Control group, 18 in the Smoker/Test group, and 6 in the Case Study group. For the Normal/Control group the total error scores (TESs) were significantly lower with the CFL than with the THL (p = 0.017) as it was for the Case Study group (p = 0.009). No significant differences were found between the Normal/Control group and the Smoker/Test group for each light source. Decision tree analysis found pack years to be a significant variable for TES. Discussion: All three light sources were comparable with previous studies. The CFL provided better colour discrimination than the LED despite them both being 6500 K. Deuteranomalous trichromats showed a greatest deviation than normal trichromats using the LED. Conclusions: The Kosnic KCF07ALU/GU10-865 is a cost-effective alternative for colour vision testing. Smoking appears to have an effect on colour vision, but requires further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel method for determining the temperature of a radiating body. The experimental method requires only very common instrumentation. It is based on the measurement of the stationary temperature of an object placed at different distances from the body and on the application of the energy balance equation in a stationary state. The method allows one to obtain the temperature of an inaccessible radiating body when radiation measurements are not available. The method has been applied to the determination of the filament temperature of incandescent lamps of different powers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Excavations carried out in the Cova dels Jurats between 2010 and 2012 served to establish that, unlike the rest of the caves Calescoves, this one functioned as a sanctuary, with two different phases. The first one corresponds to the Final Talayotic Period, as the first cave shrine documented in the Talayotic culture. In Roman times, the place was still used as a sanctuary, but with a totally different ritual, linked to the inscriptions discovered at the entrance of the cave.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Sociedade da Água de Luso, S.A., localizada no concelho de Mealhada, é uma empresa do setor do engarrafamento de águas minerais naturais, de nascente e de consumo humano. Esta realiza as suas atividades, tendo em consideração a eficiência energética, ao longo do seu processo produtivo. Desta forma, o trabalho desenvolvido teve como objetivo o acompanhamento da implementação do sistema de monitorização e recolha de dados, que posteriormente foi útil na redução dos consumos energéticos (consumo de ar comprimido). Para além disto, também foi proposta uma medida de eficiência energética que visa a redução de energia elétrica na área da iluminação. O sistema de monitorização e recolha de dados e a criação de uma equipa de redução do consumo de ar comprimido permitiram a identificação das áreas de atuação, a monitorização das metas estipuladas no âmbito da equipa e a detecção de anomalias. A medida de eficiência energética aplicada incide na substituição de lâmpadas fluorescentes tubulares T8 por lâmpadas fluorescentes tubulares T5. Assim, a implementação deste sistema e a aplicação das medidas de eficiência energética na rede de ar comprimido no âmbito da equipa permitiram uma redução de 0,03 kWh/hL o que significa uma poupança de 5.600 € em quinze semanas. Ao nível da iluminação as medidas sugeridas permitem uma redução de 8.945 kWh/ano o que corresponde a uma poupança de 1.055 €/ano.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effluents from intensive pig farms present high nutrient concentration, mainly ammonium, contributing to water eutrophication and pollution. Microalgae ability to deplete inorganic nutrients makes them an efficient effluent bioremediation tool. Scenedesmus obliquus was grown in piggery effluent (without any pretreatment) diluted with tap water at 5%v/v (187±25mg/L N-NH4+) and compared with growth in synthetic Bristol media. A 21-days trial was performed in 1L bubble-column reactors illuminated by fluorescent and LED lamps(3klux). Microalgae growth was monitored through OD540nm, dry weight and Chlorophyll content and also by flow cytometry in terms of autofluorescence read in FL3 channel (>670 nm), cell size (FSC), internal complexity (SSC) and cell membrane integrity (PI). S. obliquus cells have grown slower in pig effluent (mmax=0.13-19d-1) than in Bristol media (mmax=0.46-0.50d-1) although after 15 days the biomass productivity observed for the pig waste cultivation, operated under LED (0.127gL-1d-1) was similar to those attained for the Bristol media after 8 and 12 days (0.130 and 0.129 gL-1d-1 using Fluorescent and LED lights, respectively). The Chlorophyll content was correlated to FL3 autofluorescence, with R2>0.97 for Bristol and R2>0.92 for pig waste cultures. Regarding cell size and complexity, Bristol cultures did not show significant differences along time, while cells grown on pig waste increased, attaining FSC and SSC values similar to those observed for Bristol cultures. However, pig waste led to higher percentage of cells with permeabilised membrane (up to 18%) than Bristol cultures (7%). For pig waste experiments, ammonium removal rates were 95% with final values within legal limits. S. obliquus cultivations proved to be an efficient system for direct piggery effluent bioremediation, attaining biomass productivities similar to those obtained in synthetic media. Using LED lighting enables to reduce the energy consumption while maintaining microalgae growth and bioremediation performance. Scale-up to an outdoor 150L photobioreactor is underway.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta Dissertação aborda a temática da eficiência energética em sistemas de iluminação fabris. Desde os primórdios da história da humanidade que a iluminação tem representado um papel importante. Não só garante condições de segurança, como começou por ser o intuito primordial das fogueiras pré-históricas, traduzindo-se num elemento de conforto. Atualmente seria impensável conceber as mais diversas atividades económicas e produtivas de um país sem iluminação. Nesse sentido a iluminação representa também um elemento fomentador de produtividade. Não é bem conhecido o impacto que a iluminação tem nos custos operacionais de uma unidade fabril. Principalmente por ser difícil de quantificar separadamente na fatura de eletricidade qual a percentagem correspondente à iluminação. Tipicamente estes custos podem ascender a 20% do orçamento global da autarquia em países desenvolvidos. Por esse motivo, o sector da iluminação tem investido esforço no sentido de promover melhores soluções de iluminação capazes de por um lado de satisfazer os requisitos do espaço a iluminar, e por outro propiciar soluções eficientes do ponto de vista energético. Estas soluções assentam essencialmente no uso de dispositivos mais eficientes (como por exemplo os LED´s ou as lâmpadas compactas fluorescentes) bem como em estratégias de controlo eficientes baseadas em dados sensoriais (como por exemplo deteção de movimento/presença). A combinação destas estratégias permite reduzir os consumos em cerca de 80% quando comparadas com soluções passivas. A empresa Amorim Cork Research Lda. é uma empresa prestadora de serviços ao universo das empresas da Corticeira Amorim, uma das maiores multinacionais de origem portuguesa. Teve origem no negócio da cortiça, em 1870, sendo hoje líder destacada no sector a nível mundial. Dada a dimensão da empresa e a sua subdivisão em várias Unidades Industriais com requisitos individuais, será expectável que a iluminação represente uma parte significativa da fatura de eletricidade. Atualmente, os vários setores encontram-se equipados com soluções de iluminação diferentes, na sua maioria empregando tecnologias passivas, noutros casos com dispositivos eficientes. Há algum interesse em migrar para soluções mais eficientes, em parte suportadas em DALI (com interface de comunicação PLC ou Zigbee).