947 resultados para Label-free redox capacitance biosensing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pre-clinical studies using murine models are critical for understanding the pathophysiological mechanisms underlying immune-mediated disorders such as Eosinophilic esophagitis (EoE). In this study, an optical coherence tomography (OCT) system capable of providing three-dimensional images with axial and transverse resolutions of 5 µm and 10 µm, respectively, was utilized to obtain esophageal images from a murine model of EoE-like disease ex vivo. Structural changes in the esophagus of wild-type (Tslpr(+/+) ) and mutant (Tslpr(-/-) ) mice with EoE-like disease were quantitatively evaluated and food impaction sites in the esophagus of diseased mice were monitored using OCT. Here, the capability of OCT as a label-free imaging tool devoid of tissue-processing artifacts to effectively characterize murine EoE-like disease models has been demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eukaryotic cells are compartmentalized into membrane-bound organelles in order to provide sheltered reaction rooms for various specific processes. Organelles are not randomly distributed in a cell or operate isolated from each other. At the contrary — some organelles are closely linked and their functions are tightly orchestrated. The most well-known example of two such organelles acting in concert are the ER and the mitochondrion that work together in order to coordinate cellular lipid biosynthesis, maintain Ca2+-homeostasis, regulate mitochondrial division and control mitochondrial/ER shape as well as to synchronize the movement of these organelles within a cell. To study the mitochondrion and its interface to the ER requires a simplified mitochondrial system. African trypanosomes represent such a system. The unicellular parasite that causes devastating diseases in humans and animals has only one large mitochondrion that does not undergo fission/fusion events except for the context of cell division. Moreover, mitochondrial functions and morphology are highly regulated throughout the life cycle of the protozoan. Central to the understanding of how mitochondria control their morphology, communicate with their surroundings and manage exchange of metabolites and transport of biopolymers (proteins, RNAs) is the mitochondrial outer membrane (MOM), as the MOM defines the boundary of the organelle. Recently, we have purified the MOM of T. brucei and characterized its proteome using label-free quantitative mass spectrometry for protein abundance profiling in combination with statistical analysis. Our results show that the trypanosomal MOM proteome consists of 82 proteins, two thirds of which have never been associated with mitochondria before. Among these, we identified novel factors required to regulate mitochondrial morphology and the long-elusive protein import machinery of T. brucei. A comparison with the MOM proteome of yeast defines a set of 17 common proteins that are likely present in the mitochondrial outer membrane of all eukaryotes. One of these is the Miro-GTPase Gem1. In yeast, this Ca2+-EF-Hand containing polypeptide is thought to be involved in a protein complex that physically tethers the mitochondrion to the ER. Interestingly, a putative tethering complex in mammalian cells was linked to the mitochondrial fusion/fission machinery. Thus, the concept of a protein complex-mediated connection seems to be a general and conserved feature. We are currently investigating, if such a protein complex exists in T. brucei and if the trypanosomal Gem1 protein is involved. This ER-subdomain associated with mitochondria has been termed mitochondria-associated ER-membranes or MAM. The MAM has recently been implicated to play a key role in Alzheimer’s disease. It is therefore of broad and general interest to establish other eukaryotic model systems in order to investigate the MAM-MOM connection in more detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In-situ geotechnical measurements of surface sediments were carried out along large subaqueous dunes in the Knudedyb tidal inlet channel in the Danish Wadden Sea using a small free-falling penetrometer. Vertical profiles showed a typical stratification pattern with a resolution of ~1 cm depicting a thin surface layer of low sediment strength and a stiffer substratum below (quasi-static bearing capacity equivalent: 1-3 kPa in the top layer, 20-140 kPa in the underlying sediment; thickness of the top layer ca. 5-8 cm). Observed variations in the thickness and strength of the surface layer during a tidal cycle were compared to mean current velocities (measured using an acoustic Doppler current profiler, ADCP), high-resolution bathymetry (based on multibeam echo sounding, MBES) and qualitative estimates of suspended sediment distributions in the water column (estimated from ADCP backscatter intensity). The results revealed an ebb dominance in sediment remobilization, and a general accretion of the bed towards low water. A loose top layer occurred throughout the tidal cycle, likely influenced by bedload transport and small events of suspended sediment resettlement (thickness: 6 +-2 cm). Furthermore, this layer showed a significant increase in thickness (e.g. from 8 cm to 16 cm) related to periods of overall deposition. These findings imply that dynamic penetrometers can conveniently serve to (1) quantify potentially mobile sediments by determining the thickness of a loose sediment surface layer, (2) unravel sediment strength development in potentially mobile sediments and (3) identify sediment accumulation. Such data are an important complement and add a new geotechnical perspective during investigations of sediment remobilization processes in highly dynamic coastal environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo de la presente tesis doctoral es el desarrollo de un nuevo concepto de biosensor óptico sin marcado, basado en una combinación de técnicas de caracterización óptica de interrogación vertical y estructuras sub-micrométricas fabricadas sobre chips de silicio. Las características más importantes de dicho dispositivo son su simplicidad, tanto desde el punto de vista de medida óptica como de introducción de las muestras a medir en el área sensible, aspectos que suelen ser críticos en la mayoría de sensores encontrados en la literatura. Cada uno de los aspectos relacionados con el diseño de un biosensor, que son fundamentalmente cuatro (diseño fotónico, caracterización óptica, fabricación y fluídica/inmovilización química) son desarrollados en detalle en los capítulos correspondientes. En la primera parte de la tesis se hace una introducción al concepto de biosensor, en qué consiste, qué tipos hay y cuáles son los parámetros más comunes usados para cuantificar su comportamiento. Posteriormente se realiza un análisis del estado del arte en la materia, enfocado en particular en el área de biosensores ópticos sin marcado. Se introducen también cuáles son las reacciones bioquímicas a estudiar (inmunoensayos). En la segunda parte se describe en primer lugar cuáles son las técnicas ópticas empleadas en la caracterización: Reflectometría, Elipsometría y Espectrometría; además de los motivos que han llevado a su empleo. Posteriormente se introducen diversos diseños de las denominadas "celdas optofluídicas", que son los dispositivos en los que se va a producir la interacción bioquímica. Se presentan cuatro dispositivos diferentes, y junto con ellos, se proponen diversos métodos de cálculo teórico de la respuesta óptica esperada. Posteriormente se procede al cálculo de la sensibilidad esperada para cada una de las celdas, así como al análisis de los procesos de fabricación de cada una de ellas y su comportamiento fluídico. Una vez analizados todos los aspectos críticos del comportamiento del biosensor, se puede realizar un proceso de optimización de su diseño. Esto se realiza usando un modelo de cálculo simplificado (modelo 1.5-D) que permite la obtención de parámetros como la sensibilidad y el límite de detección de un gran número de dispositivos en un tiempo relativamente reducido. Para este proceso se escogen dos de las celdas optofluídicas propuestas. En la parte final de la tesis se muestran los resultados experimentales obtenidos. En primer lugar, se caracteriza una celda basada en agujeros sub-micrométricos como sensor de índice de refracción, usando para ello diferentes líquidos orgánicos; dichos resultados experimentales presentan una buena correlación con los cálculos teóricos previos, lo que permite validar el modelo conceptual presentado. Finalmente, se realiza un inmunoensayo químico sobre otra de las celdas propuestas (pilares nanométricos de polímero SU-8). Para ello se utiliza el inmunoensayo de albumina de suero bovino (BSA) y su anticuerpo (antiBSA). Se detalla el proceso de obtención de la celda, la funcionalización de la superficie con los bioreceptores (en este caso, BSA) y el proceso de biorreconocimiento. Este proceso permite dar una primera estimación de cuál es el límite de detección esperable para este tipo de sensores en un inmunoensayo estándar. En este caso, se alcanza un valor de 2.3 ng/mL, que es competitivo comparado con otros ensayos similares encontrados en la literatura. La principal conclusión de la tesis es que esta tipología de dispositivos puede ser usada como inmunosensor, y presenta ciertas ventajas respecto a los actualmente existentes. Estas ventajas vienen asociadas, de nuevo, a su simplicidad, tanto a la hora de medir ópticamente, como dentro del proceso de introducción de los bioanalitos en el área sensora (depositando simplemente una gota sobre la micro-nano-estructura). Los cálculos teorícos realizados en los procesos de optimización sugieren a su vez que el comportamiento del sensor, medido en magnitudes como límite de detección biológico puede ser ampliamente mejorado con una mayor compactación de pilares, alcanzandose un valor mínimo de 0.59 ng/mL). The objective of this thesis is to develop a new concept of optical label-free biosensor, based on a combination of vertical interrogation optical techniques and submicron structures fabricated over silicon chips. The most important features of this device are its simplicity, both from the point of view of optical measurement and regarding to the introduction of samples to be measured in the sensing area, which are often critical aspects in the majority of sensors found in the literature. Each of the aspects related to the design of biosensors, which are basically four (photonic design, optical characterization, fabrication and fluid / chemical immobilization) are developed in detail in the relevant chapters. The first part of the thesis consists of an introduction to the concept of biosensor: which elements consists of, existing types and the most common parameters used to quantify its behavior. Subsequently, an analysis of the state of the art in this area is presented, focusing in particular in the area of label free optical biosensors. What are also introduced to study biochemical reactions (immunoassays). The second part describes firstly the optical techniques used in the characterization: reflectometry, ellipsometry and spectrometry; in addition to the reasons that have led to their use. Subsequently several examples of the so-called "optofluidic cells" are introduced, which are the devices where the biochemical interactions take place. Four different devices are presented, and their optical response is calculated by using various methods. Then is exposed the calculation of the expected sensitivity for each of the cells, and the analysis of their fabrication processes and fluidic behavior at the sub-micrometric range. After analyzing all the critical aspects of the biosensor, it can be performed a process of optimization of a particular design. This is done using a simplified calculation model (1.5-D model calculation) that allows obtaining parameters such as sensitivity and the detection limit of a large number of devices in a relatively reduced time. For this process are chosen two different optofluidic cells, from the four previously proposed. The final part of the thesis is the exposition of the obtained experimental results. Firstly, a cell based sub-micrometric holes is characterized as refractive index sensor using different organic fluids, and such experimental results show a good correlation with previous theoretical calculations, allowing to validate the conceptual model presented. Finally, an immunoassay is performed on another typology of cell (SU-8 polymer pillars). This immunoassay uses bovine serum albumin (BSA) and its antibody (antiBSA). The processes for obtaining the cell surface functionalization with the bioreceptors (in this case, BSA) and the biorecognition (antiBSA) are detailed. This immunoassay can give a first estimation of which are the expected limit of detection values for this typology of sensors in a standard immunoassay. In this case, it reaches a value of 2.3 ng/mL, which is competitive with other similar assays found in the literature. The main conclusion of the thesis is that this type of device can be used as immunosensor, and has certain advantages over the existing ones. These advantages are associated again with its simplicity, by the simpler coupling of light and in the process of introduction of bioanalytes into the sensing areas (by depositing a droplet over the micro-nano-structure). Theoretical calculations made in optimizing processes suggest that the sensor Limit of detection can be greatly improved with higher compacting of the lattice of pillars, reaching a minimum value of 0.59 ng/mL).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate a novel glucose sensor based on an optical fiber grating with an excessively tilted index fringe structure and its surface modified by glucose oxidase (GOD). The aminopropyltriethoxysilane (APTES) was utilized as binding site for the subsequent GOD immobilization. Confocal microscopy and fluorescence microscope were used to provide the assessment of the effectiveness in modifying the fiber surface. The resonance wavelength of the sensor exhibited red-shift after the binding of the APTES and GOD to the fiber surface and also in the glucose detection process. The red-shift of the resonance wavelength showed a good linear response to the glucose concentration with a sensitivity of 0.298nm(mg/ml)-1 in the very low concentration range of 0.0∼3.0mg/ml. Compared to the previously reported glucose sensor based on the GOD-immobilized long period grating (LPG), the 81° tilted fiber grating (81°-TFG) based sensor has shown a lower thermal cross-talk effect, better linearity and higher Q-factor in sensing response. In addition, its sensitivity for glucose concentration can be further improved by increasing the grating length and/or choosing a higher-order cladding mode for detection. Potentially, the proposed techniques based on 81°-TFG can be developed as sensitive, label free and micro-structural sensors for applications in food safety, disease diagnosis, clinical analysis and environmental monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protein oxidation is thought to contribute to a number of inflammatory diseases, hence the development of sensitive and specific analytical techniques to detect oxidative PTMs (oxPTMs) in biological samples is highly desirable. Precursor ion scanning for fragment ions of oxidized amino acid residues was investigated as a label-free MS approach to mapping specific oxPTMs in a complex mixture of proteins. Using HOCl-oxidized lysozyme as a model system, it was found that the immonium ions of oxidized tyrosine and tryptophan formed in MS(2) analysis could not be used as diagnostic ions, owing to the occurrence of isobaric fragment ions from unmodified peptides. Using a double quadrupole linear ion trap mass spectrometer, precursor ion scanning was combined with detection of MS(3) fragment ions from the immonium ions and collisionally-activated decomposition peptide sequencing to achieve selectivity for the oxPTMs. For chlorotyrosine, the immonium ion at 170.1 m/z fragmented to yield diagnostic ions at 153.1, 134.1, and 125.1 m/z, and the hydroxytyrosine immonium ion at 152.1 m/z gave diagnostic ions at 135.1 and 107.1 m/z. Selective MS(3) fragment ions were also identified for 2-hydroxytryptophan and 5-hydroxytryptophan. The method was used successfully to map these oxPTMs in a mixture of nine proteins that had been treated with HOCl, thereby demonstrating its potential for application to complex biological samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Development of mass spectrometry techniques to detect protein oxidation, which contributes to signalling and inflammation, is important. Label-free approaches have the advantage of reduced sample manipulation, but are challenging in complex samples owing to undirected analysis of large data sets using statistical search engines. To identify oxidised proteins in biological samples, we previously developed a targeted approach involving precursor ion scanning for diagnostic MS3 ions from oxidised residues. Here, we tested this approach for other oxidations, and compared it with an alternative approach involving the use of extracted ion chromatograms (XICs) generated from high-resolution MSMS data using very narrow mass windows. This accurate mass XIC data methodology was effective at identifying nitrotyrosine, chlorotyrosine, and oxidative deamination of lysine, and for tyrosine oxidations highlighted more modified peptide species than precursor ion scanning or statistical database searches. Although some false positive peaks still occurred in the XICs, these could be identified by comparative assessment of the peak intensities. The method has the advantage that a number of different modifications can be analysed simultaneously in a single LC-MSMS run. This article is part of a Special Issue entitled: Posttranslational Protein modifications in biology and Medicine. Biological significance: The use of accurate mass extracted product ion chromatograms to detect oxidised peptides could improve the identification of oxidatively damaged proteins in inflammatory conditions. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the development and simplification of label-free fiber optic biosensors based on immobilization of oligonucleotides on dual-peak long period gratings (dLPGs). This improvement is the result of a simplification of biofunctionalization methodology. A one-step 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC)-mediated reaction has been developed for the straightforward immobilization of unmodified oligonucleotides on the glass fiber surface along the grating region, leading to covalent attachment of a 5´-phosphorylated probe oligonucleotide to the amino-derivatized fiber grating surface. Immobilization is achieved via a 5´phosphate-specific linkage, leaving the remainder of the oligonucleotide accessible for binding reactions. The dLPG has been tested in different external media to demonstrate its inherent ultrahigh sensitivity to the surrounding-medium refractive index (RI) achieving 50- fold improvement in RI sensitivity over the previously-published LPG sensor in media with RI’s relevant to biological assays. After functionalization, the dLPG biosensor was used to monitor the hybridization of complementary oligonucleotides showing a detectable oligonucleotide concentration of 4 nM. The proposed one-step EDC reaction approach can be further extended to develop fiber optic biosensors for disease analysis and medical diagnosis with the advances of label-free, real-time, multiplex, high sensitivity and specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a highly sensitive, high Q-factor, label free and selective glucose sensor by using excessively tilted fiber grating (Ex-TFG) inscribed in the thin-cladding optical fiber (TCOF). Glucose oxidase (GOD) was covalently immobilized on optical fiber surface and the effectiveness of GOD immobilization was investigated by the fluorescence microscopy and highly accurate spectral interrogation method. In contrast to the long period grating (LPG) and optical fiber (OF) surface Plasmon resonance (SPR) based glucose sensors, the Ex-TFG configuration has merits of nearly independent cross sensitivity of the environmental temperature, simple fabrication method (no noble metal deposition or cladding etching) and high detection accuracy (or Q-factor). Our experimental results have shown that Ex-TFG in TCOF based sensor has a reliable and fast detection for the glucose concentration as low as 0.1~2.5mg/ml and a high sensitivity of ~1.514nm·(mg/ml)−1, which the detection accuracy is ~0.2857nm−1 at pH 5.2, and the limit of detection (LOD) is 0.013~0.02mg/ml at the pH range of 5.2~7.4 by using an optical spectrum analyzer with a resolution of 0.02nm.