944 resultados para LETHAL RADIATION DOSE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program
Resumo:
The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose
Resumo:
The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: A morphological and ultra-structural study of copper vapor laser (λ = 510.6 nm) effects on enamel and dentine was performed to show the effects of this radiation. Methods: A total of 15 human molars were cut in half; 15 pieces were separated for irradiation on enamel and 15 for dentine. These two groups were further divided into five experimental groups, including a control group, comprised of three half-sections each, irradiated by a CVL laser with a power of 7 W, a repetition rate of 15,000 pulses/sec and exposed at 500, 600, and 800 msec and 1 sec irradiation times with a 5-sec interval between irradiations. Results: In an ultra-structural SEM exam, we observed that on the enamel surfaces irradiated for 1 sec there was morphological alteration that consisted of catering, flaking, and melting on the surfaces. There was no alteration for the other exposure times. On the dentine teeth irradiated for 1 sec, we observed an evident ultra-structural alteration of melted tissue and loss of morphological characteristics. In the dentine group irradiated by 800 msec, we observed ablation and a partial loss of morphological characteristics. In the dentine groups irradiated by 500 and 600 msec, no alteration was observed. Conclusions: The results showed that irradiation with CVL promoted morphologic changes in the enamel as well as in the dentine and demonstrated a need for future studies in order to establish a safe protocol for further use in the odontological practice.
Resumo:
The thermoluminescence intensity as a function of gamma-ray dose of the 325 degreesC peak, in quartz grains extracted from sea sediments and from fluvial aeolic dunes, is studied. It is found that the response curve at low doses has a concavity directed opposite to that of quartz grains extracted from archaeological potteries. To explain this behavior a model is proposed here based on oxygen vacancies and [AlO4/h](0) centers. The experimentally observed ESR intensity of E-I'-centers as a function of radiation dose can also be explained by this model.
Resumo:
Head and neck tumors are a major health concern worldwide, due to their high incidence and mortality rates, particularly in developing countries. In Brazil, this type of cancer is commonly diagnosed and studies suggested that it may be the leading cause of mortality in the country. The increase in life expectancy worldwide, as well as environmental and behavioral factors, are related to carcinogenesis. Therefore, an understanding of basic epidemiology and statistical methods is critical, in order to promote early diagnosis and cancer prevention. Cancer patients with an indication for prosthesis were selected from the medical records of the Oral Oncology Center, School of Dentistry, São Paulo State University (UNESP), Araçatuba, between 1991 and 2010. The following variables were recorded: gender, age, type and location of the lesion, radiation dose and dental prosthesis. The majority of the patients were male (74.15%) and >60 years of age (53.37%). Tumors were most commonly located in the floor of the mouth (11.1%) and squamous cell carcinoma was the most prevalent type (72.8%). This study provides the profiles of patients who attended the Oral Oncology Center and the results may aid in the creation of cancer prevention programs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The study of ionizing radiation effects on semiconductor devices is of great relevance for the global technological development and is a necessity in some strategic areas in Brazil. This work presents preliminary results of radiation effects in MOSFETs that were exposed to 3.2 Grad radiation dose produced by a 2.6-MeV proton beam. The focus of this work was to electrically characterize a Rectangular-Gate MOSFET (RGT) and a Circular-Gate MOSFET (CGT), manufactured with the On Semiconductor 0.5 mu m standard CMOS fabrication process and to verify a suitable geometry for space applications. During the experiment, I-DS x V-GS curves were measured. After irradiation, the RGT off-state current (I-OFF) increased approximately two orders of magnitude reaching practically the same value of the I-OFF in the CGT, which only doubled its value. (C) 2011 Elsevier B.V. All rights reserved.