978 resultados para Incontinència fecal
Resumo:
In the present study, pregnancy and the estrous cycle were monitored in captive brown brocket deer (Mazama gouazoubira) by measuring fecal progestagens with a commercial enzyme immunoassay (EIA), along with behavioral data. Fecal samples were collected twice a week during pregnancy and daily during the estrous cycle and post-partum period. It was possible to distinguish between inter-luteal and luteal phases of the estrous cycle. Behavioral estrus corresponded with low concentrations of fecal progestagens. Samples from two consecutive cycles were available from five hinds, and the mean estrous cycle (n = 10) was 26.9 +/- 1.7 d (mean +/- S.E.M.). However, when two extreme cycles (34 and 37 d) were deleted, the mean estrous cycle was 24.7 +/- 1.2 d. Three animals became pregnant (gestation ranged from 208 to 215 d). After fertile breeding, progestagen concentration in these hinds remained among luteal phase concentrations throughout pregnancy, with the exception of a few peaks. Within 4 d post-partum, two hinds reached interluteal phase values, while one hind maintained luteal concentrations for at least 1 week. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
Objetivou-se com este trabalho avaliar a produção fecal por meio do indicador interno, fibra em detergente neutro indigestível (FDNi), e externos, cromo complexado com ácido etilenodiaminotetracético (Cr-EDTA ) e o cloreto de itérbio (YbCl3), além de estimar o fluxo duodenal da matéria seca e os coeficientes de digestibilidades aparentes total, ruminal e pós-ruminal, de diferentes nutrientes. Foram utilizadas oito novilhas mestiças Holandês/Zebu, distribuídas em duplo quadrado latino 4 x 4. Os indicadores Cr-EDTA, YbCl3 e o FDNi não estimaram produção fecal de forma eficiente (p < 0,05), obtendo resultado de 1,64; 1,71 e 2,71 kg dia-1, respectivamente, quando comparado à coleta total de fezes, que obteve resultado de 1,39 kg dia-1. Os valores estimados de fluxo de matéria seca, tanto para a metodologia de único, quanto para de duplo indicador, podem ser considerados biologicamente aceitáveis. Contudo, o valor obtido pela associação Cr-EDTA/YbCl3, utilizada na forma de duplo indicador, foi o mais confiável, pela melhor recuperação dos indicadores externos (Cr-EDTA e YbCl3), que obtiveram médias de 89 e 85%, respectivamente, em comparação ao interno (FDNi), que obteve média 67%. Os coeficientes de digestibilidade ruminal e pós ruminal, estimados pela associação Cr-EDTA/YbCl3, foram considerados melhores, em consequência do valor de fluxo de matéria seca estimado por esta associação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Influence of Radiotransmitters on Fecal Glucocorticoid Levels of Free-Ranging Male American Kestrels
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Produção Fecal e Fluxo Duodenal de Matéria Seca e Matéria Orgânica Estimados por Meio de Indicadores
Resumo:
O objetivo deste trabalho foi comparar os indicadores internos, fibra em detergente neutro e fibra em detergente ácido indigestíveis, obtidos após 144h de incubação in vitro e in situ (FDNiv; FDNis; FDAiv; FDAis) com o indicador externo, o óxido crômico (Cr2O3), para estimativas da produção fecal, do fluxo duodenal de matéria seca e matéria orgânica em novilhos mestiços (HxZ) confinados. Foram utilizadas dietas à base de silagens de milho, de raspa e de casca de mandioca, e também de cana-de-açúcar ensilada com polpa cítrica peletizada. Os novilhos foram castrados e canulados no rúmen e no duodeno. O período experimental teve 11 dias de adaptação às dietas e 8 dias de coleta. O delineamento experimental foi o quadrado latino (4x4), com quatro tratamentos, num arranjo em parcela subdividida, sendo as dietas estudadas nas parcelas, e os indicadores nas subparcelas. Os resultados obtidos em percentagem do peso vivo para a estimativa da produção fecal, utilizando-se os diferentes indicadores, mostraram que a FDAiv (0,88 %), a FDAis (0,85 %) e o Cr2O3 (0,99 %), embora com diferenças significativas, podem ser utilizados pelos resultados biologicamente consistentes. Para estimar o fluxo duodenal de matéria seca e matéria orgânica, foram utilizados os valores de produção fecal obtidos com a FDAiv. Os indicadores internos não apresentaram diferenças entre si para o fluxo duodenal de matéria seca, com média de 3,29 kg/dia, porém o óxido crômico superestimou o fluxo (4,95 kg/dia). Para o fluxo duodenal de matéria orgânica não houve diferença entre os indicadores com média de 2,73 kg/dia.
Resumo:
Foram realizados três experimentos procurando avaliar a utilização de dois marcadores internos (FDN e FDA indigestíveis), obtidos por meio da incubação in vitro e in situ, e de um marcador externo (óxido crômico) para estimativa da produção fecal e do fluxo da digesta duodenal em bovinos. Para análise dos dados, adotou-se o delineamento em blocos inteiramente ao acaso, sendo os tratamentos distribuídos em esquema fatorial, constituindo cinco marcadores e três volumosos. Os teores de FDN e FDA indigestíveis mostraram-se variáveis para cada volumosos, independentemente da metodologia utilizada (in vitro ou in situ), indicando que possivelmente a incubação por 144 horas não reproduz a fração indigestível total. As estimativas de produção fecal e de fluxo da digesta duodenal, obtidas por intermédio dos marcadores avaliados, apresentaram comportamento bastante diferenciado de acordo com cada volumoso. Os marcadores internos (FDN e FDA indigestíveis) podem ser utilizados como preditores dos parâmetros avaliados, desde que alguns cuidados sejam tomados na sua determinação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: Radical prostatectomy surgery is the best treatment currently adopted by detecting prostate cancer. The urinary incontinence is one more common and difficult to treat postoperative complications, which causes a negative impact on quality of life of the individual prostatectomy . The surface electrical nerve stimulation involves the transmission of electrical impulses from an external stimulator for peripheral nerve through surface electrodes attached to skin. It is an easy and efficient technique, widely used for pain relief, rehabilitation and muscle strengthening. Objective: To analyze the effect of T10-L2 percutaneous electrical stimulation, in individuals with urinary incontinence who underwent radical prostatectomy by the laparoscopic technique. Methods: Six patients had previously undergone radical prostatectomy were submitted to 20 sections of surface electrical stimulation with frequency of 4 Hz, pulse width of 1ms during 20 minutes. All subjects fillid a quality of life - International Consultation on Incontinence Questionnaire- Short FormI - ICIQ-SF questionnaire evaluating. Results: Results showed reduction in the use of the number of pads, number of leaks before and after treatment, and reduced voiding frequency and consequent improvement in quality of life. No side effects were reported. Conclusion: Percutanous electrical stimulation in T10-L2 may be an effective technique to treat urinary incontinence (UI) after radical prostatectomy video laparoscopy
Resumo:
Este artigo é parte de uma pesquisa qualitativa mais abrangente que utilizou como referencial teórico-metodológico a Grounded Theory e o Interacionismo Simbólico, resultando no modelo teórico denominado Entre o sofrimento e a esperança: a reabilitação da incontinência urinária como componente interveniente. Com a intenção de comunicar todo o conhecimento produzido, apresenta-se parte desse modelo, referente ao processo de enfrentamento da incontinência urinária por mulheres sem perspectivas de acesso ao tratamento cirúrgico, após falha dos procedimentos conservadores. Ao inter-relacionar os componentes (categorias e subcategorias) relativos à experiência dessas mulheres, buscando compará-los e analisá-los para compreender a interação entre eles, notou-se vulnerabilidade moral e psicossocial no movimento da experiência do grupo, suscetibilizando-o a riscos à saúde e ao comprometimento da qualidade de vida. Pesquisas são necessárias para aprofundar a compreensão de experiências em que haja barreira ao tratamento cirúrgico por descrédito do profissional médico sobre sua efetividade.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: avaliar a concordância dos diferentes parâmetros urodinâmicos comparados à cistometria simplificada, permitindo uma diminuição na relação custo-benefício no diagnóstico da incontinência urinária de esforço (IUE) na mulher. MÉTODOS: foram coletadas e avaliadas retrospectivamente as informações contidas dos prontuários de trinta pacientes acompanhadas, no período de janeiro de 2000 a março de 2001. Todas foram submetidas a exame físico geral e ginecológico. O estudo urodinâmico foi realizado pela técnica convencional, utilizando-se aparelho Dynograph Recorder R-611. A cistometria simplificada foi realizada com auxílio de um equipo em Y de PVC (pressão venosa central), conectado a um sonda de Foley 14 F, que permitia tanto a infusão de soro fisiológico como a captação da pressão intra-vesical. Foram analisados os parâmetros: volume residual, capacidade vesical, complacência, presença de contrações involuntárias do detrusor e perdas urinárias aos esforços. Para determinação da proporção de concordância entre os métodos foram utilizados o teste de concordância de Pearson e o teste de Wilcoxon, para amostras relacionadas. RESULTADOS: a média de idade foi de 50 anos, com extremos variando de 28 a 70 anos. O índice de concordância entre os estudos, na demonstração das perdas urinárias aos esforços, foi de 67%. Para a detecção das contrações involuntárias do detrusor, a proporção de concordância foi de 90%. A média do volume residual encontrado na cistometria simplificada foi de 16,8 ml contra 2 ml da urodinâmica convencional, com diferença significativa (p < 0,01). A média de capacidade vesical máxima no estudo urodinâmico foi de 440,5 ml, enquanto que, na cistometria simplificada, foi de 387 ml (p < 0,05). A complacência vesical foi, em média, significativamente maior na cistometria simplificada (43,0 ml/cmH2O) quando comparada ao estudo urodinâmico (31,5 ml/cmH2O), com p < 0,01. CONCLUSÃO: Avaliações preliminares sugerem que a propedêutica uroginecológica associada à cistometria simplificada é uma opção a ser considerada na avaliação clínica e pré-operatória de pacientes com IUE em substituição à urodinâmica convencional, particularmente onde esta última não se encontra disponível. A cistometria simplificada é um exame acessível que é capaz de detectar contrações involuntárias do detrusor, assim como identificar perdas urinárias com relativa sensibilidade, proporcionando ao examinador noções fidedignas do comportamento vesical.