889 resultados para Impedance Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This publication is a support and resource document for the "National Action Plan for Promotion, Prevention and Early Intervention for Mental Health 2000". It includes indicators, measurement tools and databases relevant to assessing the implementation of the outcomes and strategies identified in the action plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is described whereby sedimentation velocity is combined with equilibrium dialysis to determine the net charge (valence) of a protein by using chromate as an indicator ion for assessing the extent of the Donnan redistribution of small ions. The procedure has been used in experiments on bovine serum albumin under slightly alkaline conditions (pH 8.0, I 0.05) to illustrate its application to a system in which the indicator ion and protein both bear net negative charge and on lysozyme under slightly acidic conditions (pH 5.0, I 0.10) to illustrate the situation where chromate is a counterion. (C) 2001 Elsevier Science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of total body water by measuring bioelectrical impedance at a fixed frequency of 50 kHz is useful in assessing body composition in healthy populations. However, in cirrhosis, the distribution of total body water between the extracellular and intracellular compartments is of greater clinical importance. We report an evaluation of a new multiple-frequency bioelectrical-impedance analysis technique (MFBIA) that may quantify the distribution of total body water in cirrhosis. In 21 cirrhotic patients and 21 healthy control subjects, impedance to the Row of current was measured at frequencies ranging from 4 to 1012 kHz. These measurements were used to estimate body water compartments and then compared with total body water and extracellular water determined by isotope methodology. In cirrhotic patients, extracellular water and total body water (as determined by isotope methods) were well predicted by MFBIA (r = 0.73 and 0.89, respectively).;However, the 95% confidence intervals of the limits of agreement between MFBIA and the isotope methods were +/- 14% and +/-9% for cirrhotics (extracellular water and total body water, respectively) and +/-9% and +/-9% for cirrhotics without ascites. The 95% confidence intervals estimated from the control group were +/-10% and +/-5% for extracellular water and total body water, respectively. Thus, despite strong correlations between MFBIA and isotope measurements, the relatively large limits of agreement with accepted techniques suggest that the MFBIA technique requires further refinement before it can be routinely used to determine the nutritional assessment of individual cirrhotic patients. Nutrition 2001,17.31-34. (C)Elsevier Science Inc. 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional methods for detecting differences in microsatellite repeat lengths rely on electrophoretic fractionation on long denaturing polyacrylamide gels, a time-consuming and labor-intensive method. Therefore, there is a need for the development of new and rapid approaches to routinely detect such length polymorphisms. The advent of techniques allowing the coupling of DNA molecules to solid surfaces has provided new prospects in the area of mutation. We describe here the development and optimization of the ligase-assisted spacer addition (LASA) method, a novel and rapid procedure based on an ELISA format to measure microsatellite repeat lengths. The LASA assay was successfully applied to a set of 11 bird samples to assess its capability as a genotyping method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study was designed to investigate the immediate effect of exercise intensity and duration on body fluid volumes in rats throughout a 3-wk exercise program. Methods: Changes in the extracellular water (ECW) and total body water (TBW) volumes of rats were measured preexercise and postexercise using multiple frequency bioelectrical impedance analysis. Groups of rats were exercised at two intensities (6 m.min(-1) and 12 m.min(-1)) for two exercise times (60 min and 90 min) 5 d.wk(-1) during a 3-wk period. Changes in plasma electrolytes, glucose, and lactate resulting from the exercise were also measured on 3 d of each week. Results: Each group of animals showed significant losses in ECW and TBW as a direct result of daily exercise. The magnitude of fluid loss was directly related to the intensity of the exercise, bur not to exercise duration; although the magnitude of daily fluid loss at the higher intensity exercise (12 m.min(-1)) decreased as the study progressed, possibly indicating a training effect. Conclusion: At low-intensity exercise, there is a small bur significant loss in both TBW and ECW fluids, and the magnitude of these losses does not change throughout a 3-wk exercise program. At moderate levels of exercise intensity, there is a greater loss of both TBW and ECW fluids. However, the magnitudes of these losses decrease significantly during the 3-wk exercise program, thus demonstrating a training effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/-0.65 mm for the manual and 0.03 +/-0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were -0.07 +/-0.38 mm for observer 1 and -0.16 +/-0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.