992 resultados para INTRAOCULAR-PRESSURE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To assess the intraocular pressure (IOP)-lowering effect of travoprost 0.004%/timolol 0.5% fixed-dose combination (TRAV/TIM-FC) in patients not achieving the target IOP of ≤18 mmHg while on timolol 0.5% (TIM) monotherapy. A multicenter, prospective, open-label study (NCT01336569) was conducted in patients with open-angle glaucoma or ocular hypertension. Eligible patients were receiving TIM monotherapy with a screening/baseline IOP of 19-35 mmHg in ≥1 eye. TIM was discontinued on the baseline visit day (no washout period) and TRAV/TIM-FC was initiated and administered once daily at 8 pm for 4-6 weeks. The primary efficacy variable was mean change in IOP from TIM-treated baseline to study end, measured by Goldmann applanation tonometry. Results were analyzed by analysis of variance and paired samples t-test (5% significance). A total of 49 patients were enrolled (mean age, 63 [range, 42-82] years; 55.1% White; 73.5% women), and 45 were included in the intent-to-treat (ITT) population. Mean duration of treatment with TRAV/TIM-FC was 31 days. Mean ± standard deviation IOP reduction from baseline (TIM) to the follow-up visit (TRAV/TIM-FC) was -5.0±3.6 mmHg. IOP decreased significantly (P<0.0001) from baseline (22.1±2.6 mmHg) to study end (17.1±3.9 mmHg) in the ITT population, with a mean IOP reduction of 22.3%. Most patients (n=33/45; 73.3%) achieved IOP ≤18 mmHg. Two patients experienced a total of four adverse events (AEs), including a patient who reported one serious AE (enterorrhagia) that was considered unrelated to treatment, and a patient who reported one event each of drug-related redness, pruritus, and foreign body sensation. Most patients (n=47/49; 95.9%) reported no AEs. TRAV/TIM-FC lowered IOP in patients who were not at target IOP while receiving TIM monotherapy, with most patients achieving an IOP ≤18 mmHg with TRAV/TIM-FC. TRAV/TIM-FC was well tolerated in this population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To assess visual outcomes and patient satisfaction following implantation of the Sulcoflex® multifocal intraocular lens (IOL; Rayner Intraocular Lenses Ltd., Hove, UK) in a procedure combining capsular bag lens implantation with sulcus placement of the Sulcoflex® IOL. Setting: Instituto de Oftalmologia de Assis, Assis, SP, Brazil. Methods: Cataract patients > 45 years, with hyperopia ≥ 1.50 D and potential acuity measurement ≥ 20/30 undergoing Sulcoflex® multifocal IOL implantation were included. Monocular and binocular uncorrected near and distance visual acuity (VA) were evaluated at five days, one month, and three months postoperatively. Contrast sensitivity and refraction were measured in a subset of patients three months postoperatively. Patient satisfaction was assessed one month postoperative. Results: This non-consecutive case series comprised 25 eyes of 13 patients. Eleven eyes (52%) had pre-existing retinal pathologies. Monocular distance VA improved significantly at all follow-up visits. At final follow-up, 88% of eyes had monocular uncorrected distance VA (UDVA) of at least 20/25 and 24% had monocular UDVA of 20/20. All eyes had binocular UDVA of at least 20/25, and 58% had binocular UDVA of 20/20. Monocular uncorrected near vision (UNVA) was J1 in 68% of eyes and all patients had binocular UNVA of J1. Of all eyes studied, 92% and 58% achieved a spherical equivalent within 1 D and −0.5 D, respectively. The majority of patients reported satisfaction with visual outcomes. Complications included a postoperative intraocular pressure spike in four eyes. Conclusion: The Sulcoflex® multifocal IOL improves near and distance VA in cataract patients with retinal abnormalities and good VA potential.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To study changes in lamina cribrosa position and prelaminar tissue thickness (PTT) after surgical IOP reduction in glaucoma patients. METHODS. Twenty-two patients (mean age, 71.4 years) were imaged with spectral domain optical coherence tomography (SD-OCT; 24 radial B-scans centered on the optic nerve head [ONH]) before trabeculectomy or tube shunt implantation. Follow up images were acquired 1 week, 1 month, 3 months, and 6 months postsurgery. Bruch's membrane opening (BMO), the internal limiting membrane (ILM) and the anterior laminar surface (ALS) were segmented in each radial scan with custom software. Surfaces were fitted to the ILM and ALS with the extracted three-dimesional coordinates. PTT was the distance between the ILM and ALS, perpendicular to a BMO reference plane. Serial postsurgical laminar displacement (LD), relative to the BMO reference plane, and changes in PTT were measured. Positive values indicated anterior LD. RESULTS. Mean (SD) presurgery IOP was 18.1 (6.5) mm Hg, and reduced by 4.7 (5.5), 2.4 (7.7), 7.0 (6.2), and 6.8 (7.5) mm Hg at 1 week, 1 month, 3 months, and 6 months postsurgery, respectively. At the four postsurgery time points, there was significant anterior LD (1.8 [9.5], -1.1 [8.9], 8.8 [20.2], and 17.9 [25.8] mu m) and PTT increase (1.7 [13.3], 2.4 [11.9], 17.4 [13.7], and 13.9 [18.6] mu m). LD was greater in ONHs with larger BMO area (P = 0.01) and deeper ALS (P = 0.04); however, PTT was not associated with any of the tested independent variables. CONCLUSIONS. Both anterior LD and thickening of prelaminar tissue occur after surgical IOP reduction in patients with glaucoma. (Invest Ophthalmol Vis Sci. 2012;53:5819-5826) DOI:10.1167/iovs.12-9924

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oxidative stress and mitochondrial impairment are essential in the ischemic stroke cascade and eventually lead to tissue injury. C-Phycocyanin (C-PC) has previously been shown to have strong antioxidant and neuroprotective actions. In the present study, we assessed the effects of C-PC on oxidative injury induced by tert-butylhydroperoxide (t-BOOH) in SH-SY5Y neuronal cells, on transient ischemia in rat retinas, and in the calcium/phosphate-induced impairment of isolated rat brain mitochondria (RBM). In SH-SY5Y cells, t-BOOH induced a significant reduction of cell viability as assessed by an MTT assay, and the reduction was effectively prevented by treatment with C-PC in the low micromolar concentration range. Transient ischemia in rat retinas was induced by increasing the intraocular pressure to 120 mmHg for 45 min, which was followed by 15 min of reperfusion. This event resulted in a cell density reduction to lower than 50% in the inner nuclear layer (INL), which was significantly prevented by the intraocular pre-treatment with C-PC for 15 min. In the RBM exposed to 3 mM phosphate and/or 100 mu M Ca2+, C-PC prevented in the low micromolar concentration range, the mitochondrial permeability transition as assessed by mitochondrial swelling, the membrane potential dissipation, the increase of reactive oxygen species levels and the release of the pro-apoptotic cytochrome c. In addition, C-PC displayed a strong inhibitory effect against an electrochemically-generated Fenton reaction. Therefore, C-PC is a potential neuroprotective agent against ischemic stroke, resulting in reduced neuronal oxidative injury and the protection of mitochondria from impairment. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine the proportion of blindness and investigate the relationships between risk factors based on clinical characteristics and development of blindness in patients with primary open-angle glaucoma (POAG) treated for at least 15 years. Methods: A retrospective observational chart review was performed with 403 patients referred to a tertiary level hospital, each with a diagnosis of primary open-angle glaucoma, treated for at least 15 years. Blindness attributable to glaucoma was defined based on visual acuity and/or visual field tests. Variables considered to be possible risk factors for blindness were evaluated using odds ratio (OR), confidence interval (95% CI), and univariate and multivariate analyses. Results: Thirty-one patients became blind [13/53 (24.5%) - unilaterally and 18/53 (34%) - bilaterally] during the follow-up period of treatment (19.5 +/- 4.6 years, range 15-31 years). Multivariate statistics with regression analysis revealed that persistency on initial therapy <= 6 months was significantly associated with blindness, both unilateral (OR: 8.4; 95% CI: 1.3-56.4) and bilateral (OR: 7.2; 95% CI: 1.3-39.6). Other potential factors such as race, age, gender or number of medications were not associated with blindness. Conclusion: Blindness from primary open-angle glaucoma was not uncommon in this population of treated patients after the long follow-up period proposed. Persistence rates with the first therapy, as measured by a medical decision to change, were low. Persistence <= 6 months was statistically associated with the development of unilateral and bilateral blindness from glaucoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To report the results of a Latin American consensus panel regarding the diagnosis and management of primary open-angle glaucoma and to compare these results with those from a similar panel in the United States. DESIGN: A RAND-like (Research and Development) appropriateness methodology was used to assess glaucoma practice in Latin America. METHODS: The 148 polling statements created for the RAND-like analysis in the United States and 10 additional statements specific to glaucoma care in Latin America were presented to a panel of Latin American glaucoma experts. Panelists were polled in private using the RAND-like methodology before and after the panel meeting. RESULTS: Consensus agreement or disagreement among Latin American experts was reached for 51.3% of statements before the meeting and increased to 66.5% in the private, anonymous meeting after polling (79.0% agreement, 21.0% disagreement). Although there was a high degree of concordance (111 of 148 statements; 75%) between the results of this Latin American panel and the United States panel, there were some notable exceptions relating to diagnostic and therapeutic decision making. CONCLUSIONS: This RAND-like consensus methodology provides a perspective of how Latin American glaucoma practitioners view many aspects of glaucoma and compares these results with those obtained using a similar methodology from practitioners in the United States. These findings may be helpful to ophthalmologists providing glaucoma care in Latin America and in other regions of the world. (Am J Ophthalmol 2012;154: 460-465. (C) 2012 by Elsevier Inc. All rights reserved.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To characterize optic nerve head (ONH) anatomy related to the clinical optic disc margin with spectral domain-optical coherence tomography (SD-OCT). Design: Cross-sectional study. Participants: Patients with open-angle glaucoma with focal, diffuse, and sclerotic optic disc damage, and age-matched normal controls. Methods: High-resolution radial SD-OCT B-scans centered on the ONH were analyzed at each clock hour. For each scan, the border tissue of Elschnig was classified for obliqueness (internally oblique, externally oblique, or nonoblique) and the presence of Bruch's membrane overhanging the border tissue. Optic disc stereophotographs were co-localized to SD-OCT data with customized software. The frequency with which the disc margin identified in stereophotographs coincided with (1) Bruch's membrane opening (BMO), defined as the innermost edge of Bruch's membrane; (2) Bruch's membrane/border tissue, defined as any aspect of either outside BMO or border tissue; or (3) border tissue, defined as any aspect of border tissue alone, in the B-scans was computed at each clock hour. Main Outcome Measures: The SD-OCT structures coinciding with the disc margin in stereophotographs. Results: There were 30 patients (10 with each type of disc damage) and 10 controls, with a median (range) age of 68.1 (42-86) years and 63.5 (42-77) years, respectively. Although 28 patients (93%) had 2 or more border tissue configurations, the most predominant one was internally oblique, primarily superiorly and nasally, frequently with Bruch's membrane overhang. Externally oblique border tissue was less frequent, observed mostly inferiorly and temporally. In controls, there was predominantly internally oblique configuration around the disc. Although the configurations were not statistically different between patients and controls, they were among the 3 glaucoma groups. At most locations, the SD-OCT structure most frequently identified as the disc margin was some aspect of Bruch's membrane and border tissue external to BMO. Bruch's membrane overhang was regionally present in the majority of patients with glaucoma and controls; however, in most cases it was not visible as the disc margin. Conclusions: The clinically perceived disc margin is most likely not the innermost edge of Bruch's membrane detected by SD-OCT. These findings have important implications for the automated detection of the disc margin and estimates of the neuroretinal rim. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012;119:738-747 (C) 2012 by the American Academy of Ophthalmology.