922 resultados para IMML and Visual IMML


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of stress and anxiety on the pressure pain threshold (PPT) of masticatory muscles and on the subjective pain report. Forty-five women, students, with mean age of 19.75 years, were divided into two groups: group 1:29 presenting with masticatory myofascial pain (MFP), according to the Research Diagnostic Criteria for Temporomandibular Disorders and group 2: 16 asymptomatic controls. An electronic algometer registered the pain thresholds on four different occasions throughout the academic year. To measure levels of stress, anxiety and pain, the Beck Anxiety Inventory, Lipp Stress Symptoms Inventory and Visual Analog Scale (VAS) were used. Three-way anova and Tukey`s tests were used to verify differences in PPT between groups, times and sites. Levels of anxiety and VAS were compared using Mann-Whitney test, while Friedman`s test was used for the within-groups comparison at different times (T1 to T4). The chi-squared and Cochran tests were performed to compare groups for the proportion of subjects with stress (alpha = 0.05). Differences in PPT recordings between time (P = 0.001) and sites (P < 0.001) were detected. Higher levels of anxiety and lower PPT figures were detected at T2 (academic examination) (P = 0.001). There was no difference between groups for anxiety and stress at any time (P > 0.05). The MFP group also has shown significant increase of VAS at the time of academic examination (P < 0.001). External stressors such as academic examinations have a potential impact on masticatory muscle tenderness, regardless of the presence of a previous condition such as masticatory myofascial pain.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Language relating to disability in the public arena has been a sensitive issue in Japan as elsewhere. Since the 1970s and 80s, major media organisations have replaced words considered derogatory with more acceptable equivalents; laws, statutes and other legal documents have likewise been revised. This article examines how the language used to portray people with disabilities has changed, how the changes came about and how they were received. The debate has largely been played out in four public spaces, which to some extent intersect and overlap: the media (both print and visual), the laws, literature and, increasingly now, the Internet. I argue that while the laws were rewritten primarily as the result of external international trends, such as the International Year of Disabled Persons, disability groups achieved media compliance mainly by exploiting the keen desire of Japanese media organisations to avoid public embarrassment resulting from vocal protests over infractions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Most Internet search engines are keyword-based. They are not efficient for the queries where geographical location is important, such as finding hotels within an area or close to a place of interest. A natural interface for spatial searching is a map, which can be used not only to display locations of search results but also to assist forming search conditions. A map-based search engine requires a well-designed visual interface that is intuitive to use yet flexible and expressive enough to support various types of spatial queries as well as aspatial queries. Similar to hyperlinks for text and images in an HTML page, spatial objects in a map should support hyperlinks. Such an interface needs to be scalable with the size of the geographical regions and the number of websites it covers. In spite of handling typically a very large amount of spatial data, a map-based search interface should meet the expectation of fast response time for interactive applications. In this paper we discuss general requirements and the design for a new map-based web search interface, focusing on integration with the WWW and visual spatial query interface. A number of current and future research issues are discussed, and a prototype for the University of Queensland is presented. (C) 2001 Published by Elsevier Science Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Os indivíduos com idade ≥ 50 anos representam entre 65% a 82% dos casos de baixa visão e cegueira. Cerca de metade dos casos de baixa de acuidade visual são corrigíveis e cerca de 1/4 são preveníveis. As causas mais frequentes são os erros de refração (43%) e as cataratas (33%). Os idosos podem não reportar informação relacionada com queixas do foro visual, uma vez que, podem estar mais focados noutros sintomas. Objectivos: identificar a prevalência de alterações da função visual; identificar a prevalência de alterações da acuidade visual para longe e perto; identificar as alterações da acuidade visual para longe causadas por erros refrativos através do buraco estenopeico; identificar alterações da sensibilidade ao contraste, estereopsia e visão cromática; identificar a periodicidade da avaliação oftalmológica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

RESUMO: Introdução – A insuficiência de convergência (IC) pode desencadear alterações da atenção visual. Pretende-se investigar se existem alterações na atenção visual em estudantes do ensino superior com IC. Metodologia – Estudo quantitativo, comparativo e correlacional. Participaram 44 estudantes com idades compreendidas entre os 18 e os 24 anos. Formaram-se dois grupos, um com Visão Binocular Normal (VBN) e outro com IC. O grupo com IC incluiu os indivíduos que apresentaram alterações no ponto próximo de convergência (PPC) e/ou na convergência para perto (C’). Para avaliar a atenção visual utilizou-se o teste de cancelamento de sinos. Resultados – O grupo com VBN foi composto por 32 indivíduos (23 do género feminino) e o grupo com IC por 12 indivíduos (11 do género feminino). No teste de atenção visual verificou-se que o número médio de sinos identificados foi de 34,6 para o grupo com VBN e de 34,3 no grupo com IC. O tempo médio de realização do teste foi de 167,9s e de 198,3s para os grupos de VBN e IC, respetivamente. Observou-se uma correlação moderada positiva entre o PPC e o tempo médio de realização do teste (r≈0,63) e uma correlação fraca positiva entre o número médio de sinos identificados e a C’ (r≈0,16). Por outro lado, a correlação entre o PPC e o número médio de sinos identificados (r≈-0,48) foi fraca negativa e entre a C’ e o tempo médio (r≈-0,05) foi ínfima negativa. Discussão/Conclusões – O grupo com VBN apresenta um número médio de sinos identificados superior ao grupo com IC. Verifica-se ainda que o grupo com IC demorou mais tempo na realização do teste, comparativamente com o grupo com VBN. Estes resultados apontam para uma possível relação entre a IC e a diminuição da atenção visual.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 12 de Dezembro de 2013, Universidade dos Açores.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. Steatosis is usually a diffuse liver disease, since it is globally affected. However, steatosis can also be focal affecting only some foci difficult to discriminate. In both cases, steatosis is detected by laboratorial analysis and visual inspection of ultrasound images of the hepatic parenchyma. Liver biopsy is the most accurate diagnostic method but its invasive nature suggest the use of other non-invasive methods, while visual inspection of the ultrasound images is subjective and prone to error. In this paper a new Computer Aided Diagnosis (CAD) system for steatosis classification and analysis is presented, where the Bayes Factor, obatined from objective intensity and textural features extracted from US images of the liver, is computed in a local or global basis. The main goal is to provide the physician with an application to make it faster and accurate the diagnosis and quantification of steatosis, namely in a screening approach. The results showed an overall accuracy of 93.54% with a sensibility of 95.83% and 85.71% for normal and steatosis class, respectively. The proposed CAD system seemed suitable as a graphical display for steatosis classification and comparison with some of the most recent works in the literature is also presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem por Ressonância Magnética

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Structural health monitoring has long been identified as a prominent application of Wireless Sensor Networks (WSNs), as traditional wired-based solutions present some inherent limitations such as installation/maintenance cost, scalability and visual impact. Nevertheless, there is a lack of ready-to-use and off-the-shelf WSN technologies that are able to fulfill some most demanding requirements of these applications, which can span from critical physical infrastructures (e.g. bridges, tunnels, mines, energy grid) to historical buildings or even industrial machinery and vehicles. Low-power and low-cost yet extremely sensitive and accurate accelerometer and signal acquisition hardware and stringent time synchronization of all sensors data are just examples of the requirements imposed by most of these applications. This paper presents a prototype system for health monitoring of civil engineering structures that has been jointly conceived by a team of civil, and electrical and computer engineers. It merges the benefits of standard and off-the-shelf (COTS) hardware and communication technologies with a minimum set of custom-designed signal acquisition hardware that is mandatory to fulfill all application requirements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In developed countries, civil infrastructures are one of the most significant investments of governments, corporations, and individuals. Among these, transportation infrastructures, including highways, bridges, airports, and ports, are of huge importance, both economical and social. Most developed countries have built a fairly complete network of highways to fit their needs. As a result, the required investment in building new highways has diminished during the last decade, and should be further reduced in the following years. On the other hand, significant structural deteriorations have been detected in transportation networks, and a huge investment is necessary to keep these infrastructures safe and serviceable. Due to the significant importance of bridges in the serviceability of highway networks, maintenance of these structures plays a major role. In this paper, recent progress in probabilistic maintenance and optimization strategies for deteriorating civil infrastructures with emphasis on bridges is summarized. A novel model including interaction between structural safety analysis,through the safety index, and visual inspections and non destructive tests, through the condition index, is presented. Single objective optimization techniques leading to maintenance strategies associated with minimum expected cumulative cost and acceptable levels of condition and safety are presented. Furthermore, multi-objective optimization is used to simultaneously consider several performance indicators such as safety, condition, and cumulative cost. Realistic examples of the application of some of these techniques and strategies are also presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Retail services are a main contributor to municipal budget and are an activity that affects perceived quality-of-life, especially for those with mobility difficulties (e.g. the elderly, low income citizens). However, there is evidence of a decline in some of the services market towns provide to their citizens. In market towns, this decline has been reported all over the western world, from North America to Australia. The aim of this research was to understand retail decline and enlighten on some ways of addressing this decline, using a case study, Thornbury, a small town in the Southwest of England. Data collected came from two participatory approaches: photo-surveys and multicriteria mapping. The interpretation of data came from using participants as analysts, but also, using systems thinking (systems diagramming and social trap theory) for theory building. This research moves away from mainstream economic and town planning perspectives by making use of different methods and concepts used in anthropology and visual sociology (photo-surveys), decision-making and ecological economics (multicriteria mapping and social trap theory). In sum, this research has experimented with different methods, out of their context, to analyse retail decline in a small town. This research developed a conceptual model for retail decline and identified the existence of conflicting goals and interests and their implications for retail decline, as well as causes for these. Most of the potential causes have had little attention in the literature. This research also identified that some of the measures commonly used for dealing with retail decline may be contributing to the causes of retail decline itself. Additionally, this research reviewed some of the measures that can be used to deal with retail decline, implications for policy-making and reflected on the use of the data collection and analysis methods in the context of small to medium towns.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Doctoral Program in Computer Science