1000 resultados para Hospitais (Equipamentos)
Resumo:
OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.
Resumo:
OBJETIVO: Avaliação de condições dos equipamentos e dosimetria em setores de tomografia computadorizada utilizando protocolos de cabeça, abdome e coluna lombar em pacientes adultos (em três equipamentos distintos) e pediátricos com até um ano e meio de vida (em um dos equipamentos avaliados). MATERIAIS E MÉTODOS: Foram estimados o índice de dose em tomografia computadorizada e a dose média em cortes múltiplos, em exames com pacientes adultos, em três distintos equipamentos. Ainda foram estimadas as doses na superfície de entrada e as doses absorvidas em exame de cabeça para pacientes adultos e pediátricos em um dos equipamentos avaliados. RESULTADOS: Foram realizados testes de controle de qualidade, mecânicos, demonstrando que os equipamentos satisfazem as especificações de uso estabelecidas pelas normas vigentes. Os resultados da dosimetria mostraram que valores de dose média em cortes múltiplos excederam em até 109,0% os valores de níveis de referência, apresentando consideráveis variações entre os equipamentos avaliados neste estudo. As doses absorvidas obtidas com protocolos pediátricos são inferiores aos de pacientes adultos, apresentando redução de até 51,0% na tireoide. CONCLUSÃO: Neste estudo foram avaliadas as condições de operação de três equipamentos tomográficos, estabelecendo quais parâmetros devem ser trabalhados para a implantação de um programa de controle de qualidade nas instituições onde esta pesquisa foi desenvolvida.
Resumo:
OBJETIVO: Verificar a concordância dos resultados apresentados por diferentes métodos de medida e as variações apresentadas na aplicação deles em diferentes equipamentos mamográficos. MATERIAIS E MÉTODOS: Foram realizadas 10 medidas de força de compressão para cada método proposto em cada equipamento avaliado (Mammomat 3000-Siemens, Mammo Diagnostic UC-Philips e Alpha ST-GE), sendo avaliadas as diferenças entre esses equipamentos mamográficos para aplicação dos mesmos métodos de medida e as diferenças entre os métodos aplicados. RESULTADOS: Diferenças significativas foram observadas entre os resultados para os diferentes métodos propostos, sendo o valor medido com auxílio de "balança tipo de banheiro", o que subestimou o valor da força de compressão. Cada sistema de compressão mostrou diferentes respostas para os métodos propostos. CONCLUSÃO: Diferenças foram verificadas para os sistemas de compressão e métodos utilizados. Dessa forma, a escolha do modo de realização do teste de compressão torna-se importante para aceitação de equipamentos mamográficos, e a competência para a definição do método mais adequado e realista é do responsável técnico. Sugere-se que a medida de força de compressão seja realizada com auxílio de dinamômetro de extensão e não de compressão se não se conhece o funcionamento do sistema de compressão do mamógrafo.
Resumo:
OBJETIVO: Avaliar a coincidência entre o campo luminoso e o campo de radiação, e o alinhamento do feixe de radiação dos equipamentos de raios X médico no Estado da Paraíba, por meio de dois testes de controle de qualidade. MATERIAIS E MÉTODOS: Foram utilizados os dispositivos para os testes de tamanho de campo e de alinhamento, um chassi carregado, trena e nível de bolha. Os testes de exatidão do sistema de colimação e de alinhamento do raio central do feixe de raios X foram realizados durante as inspeções sanitárias em serviços de radiologia nos anos de 2008 e 2009. RESULTADOS: No ano de 2008, 121 equipamentos de raios X foram testados no Estado da Paraíba. No ano de 2009, passaram pelos testes 117 equipamentos. Deste universo, 86 foram selecionados para a comparação por terem sido avaliados tanto no ano de 2008 como em 2009, sendo observada uma melhoria de 18,60% (n = 16) nos resultados dos testes realizados de um ano para outro. CONCLUSÃO Conclusão: Pode-se concluir que o percentual de equipamentos apresentando problemas no seu desempenho sofreu uma diminuição entre 2008 e 2009, não sendo observado programa de garantia de qualidade em nenhum dos serviços de radiologia do Estado da Paraíba.
Construção de equipamentos de refrigeração que permitem trabalhar com temperaturas de -40ºC ou -60ºC
Resumo:
In this article we describe the construction of two cooling systems with an immersion probe which will allow one to work at temperatures of either -40ºC or -60ºC. The two systems were constructed with readily available components and have been used daily for the last year in our laboratory to carry out reactions at low temperature or to cool down traps of vacuum pumps, reducing our need of dry-ice or liquid nitrogen.
Resumo:
Cleaning solutions containing EDTA are widely employed to remove incrustation despite of the costs involved. The free content of EDTA in commercial solutions may be determined by mixing an aliquot to ammonium oxalate and using a standard calcium solution as titrant. The end-point is detected by the formation of insoluble calcium oxalate after all EDTA is complexed. A system for turbidimetric detection of the end-point was envisaged to substitute the visual detection, which impaired the analyses of dark samples. The proposed method was tested with real samples and good accuracy and precision was obtained.
Resumo:
A cleaning validation method was developed and validated, based on swabbing sampling and simultaneous chromatographic determination of sulfamethoxazole (SMX) and trimethoprim (TMP) residues. The method presented limits of detection of 0.06 mg mL-1 for SMX and 0.09 mg mL-1 for TMP. It was considered selective, precise, accurate and robust according to the guidelines from ANVISA, the Brazilian regulatory agency, and International Conference on Harmonization. Mean swab recovery factors of 98.5% for SMX and 97.7% for TMP were obtained for spiked stainless steel plates. The method was successfully applied to the assay of actual swab samples collected from eleven points on an equipment surface.
Resumo:
A hydrometallurgical process applicable to printed circuit boards of small electrical and electronic devices was developed. This involved three leaching steps (60 ºC, 2 h): 6 mol L-1 NaOH, 6 mol L-1 HCl and aqua regia. NaOH removed the resin and flame retardant that covered the circuit boards. HCl dissolved the most electropositive metals and a small amount of copper (~0.3 wt%). Aqua regia dissolved the noble metals. Silver precipitated as AgCl. Gold and platinum were quantitatively extracted with pure methyl-isobutylketone and Alamine 336 (10 % vol. in kerosene), respectively. Slow evaporation of the raffinate crystallized CuCl2.4H2O (89% yield).
Resumo:
O prontuário do paciente ou do cliente, também denominado prontuário médico, é um elemento fundamental ao bom atendimento e um instrumento de educação permanente e de pesquisa, entre outras finalidades de gerenciamento hospitalar. Neste estudo, foram avaliados os modelos de prontuário utilizados em 77 (73,3%) dos 105 hospitais filiados à Associação Brasileira de Hospitais Universitários e de Ensino (Abrahue), sendo estudados pela estimativa de escores para vários de seus itens ou de partes referentes à história clínica e à evolução do paciente. O tipo predominante dos prontuários (92,2%; n = 71) era em suporte de papel e nenhum no formato eletrônico. Comparados aos prontuários dos hospitais filantrópicos (n = 23), os dos públicos (n = 54) alcançaram maiores escores (p < 0,05), mas em ambos a totalidade dos itens estudados teve baixa pontuação. Nos itens componentes da anamnese, por exemplo, enquanto o escore máximo esperado era 22, a média foi 4,3 (± 3,7), com limites de 0 e 15 e mediana de 4. Em conclusão, além da reduzida qualidade da maioria dos prontuários estudados, a quase totalidade ainda não incorporou as modernas tecnologias disponibilizadas pela ciência da informação.
Resumo:
Hospitais de ensino (HE) são aqueles que desenvolvem ações de docência, pesquisa e prestação de serviço de alta complexidade, sendo necessárias, portanto, qualidade e integralidade em suas ações, pautadas nos princípios e diretrizes do SUS. Este estudo analisa a produção científica sobre a avaliação dos hospitais de ensino. Foi realizada uma revisão sistemática,de julho a setembro de 2013, nas bases de dados eletrônicas Lilacs, Medline e SciELO, utilizando como orientador da busca o descritor “hospitais de ensino”e como critérios de inclusão: artigos que discutissem avaliação dos HEs; desenvolvidos no Brasil; disponíveis na íntegra e em português; e publicados após 2004. Assim, foram incluídos dez artigos que, por atenderem aos nossos interesses de investigação, foram lidos na íntegra e posteriormente discutidos. A revisão indicou que os estudos existentes são insuficientes para avaliar o desempenho dos HEs, sendo necessárias novas pesquisas em outras regiões do País, com abordagens metodológicas qualitativas e mistas para o desenvolvimento dessa avaliação.
Resumo:
RESUMO Hospitais de Ensino servem de cenário de prática para atividades curriculares de cursos da área da saúde, podendo ser de propriedade de uma Instituição de Ensino Superior, pública ou privada, ou formalmente conveniados a esta, apresentando como eixos de reestruturação atenção à saúde, gestão hospitalar, ensino e pesquisa. Desta forma, este trabalho tem como objetivo descrever um modelo heurístico de avaliação de Hospitais de Ensino com base nos conceitos de paradigma de pesquisa e de modelo teórico, tomando como hipótese de trabalho que a avaliação é uma aplicação da metodologia das ciências sociais. Assim, com respeito ao marco metodológico, elegemos a Avaliação de Quarta Geração de Egon G. Guba e Yvona S. Lincoln como metodologia de apreensão dos significados, valores, questões e preocupações frente aos processos de gestão, ensino, pesquisa e assistência, por meio de seus stakeholders, implicados no processo.
Resumo:
Este trabalho teve como objetivo desenvolver um modelo de programação dinâmica, para determinar o momento ótimo de substituição de equipamentos, incorporando-se as receitas geradas pelo uso e descarte da máquina. Tal modelo deverá procurar maximizar os lucros através de uma relação de recorrência referente às receitas e aos custos ao longo dos anos. Desse modo, comparou-se o modelo proposto com um tradicional de substituição, que inclui apenas custos, utilizado por Filgueiras (1997). O modelo proposto foi satisfatório, de acordo com o objetivo do trabalho, pois com o seu desenvolvimento foi possível oferecer decisões ótimas de substituir ou reter o equipamento. Tal modelo se apresentou mais flexível, podendo ser utilizado em situações em que o equipamento gera receitas diretas (como no caso de aluguel ou receitas de fretes) ou não. Quando não se utilizam receitas, os resultados são idênticos aos do modelo tradicional. Constatou-se, também, que o modelo proposto é mais suscetível a aumentos no valor de aquisição do equipamento, enquanto o modelo sem receita é mais sensível a variações na taxa de juros. Observou-se que a aplicação da Programação Dinâmica oferece ao planejador uma gama de alternativas bem maior para auxiliar a tomada de decisão.