947 resultados para Hard mask


Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. The present study was carried out to determine the target cells and tissues for anti-tick immunoglobulins using an indirect immunohistochemical technique.2. Sections in triplicate prepared from unfed ticks Rhipicephalus appendiculatus, R. evertsi and Amblyomma variegatum were used to assess the cross-reactivity of serum from guineapigs naturally infested with these tick species or immunized against them.3. The sections showed slight (+) to strong (++++) labelling of several structures in the tick body, e.g. salivary gland, gut lumen and malpighian tubules, depending on the serum used.4. The immune serum resulting from the immunization of guinea pigs with an extract of unfed nymphs of R. appendiculatus ticks showed the most intense cross-reactivity with the sections examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of increased of laryngeal mask airway (LMA) intracuff pressures on the laryngopharyngeal mucosa. Study Design: Animal model. Methods: Sixteen mixed-breed dogs were randomly allocated to two groups, G1 (intracuff volume, 30 mL; n = 8) and G2 (intracuff volume, 54 mt; n = 8), to produce, respectively, high or very high intracuff pressures. Anesthesia was induced and maintained with pentobarbital. Intracuff pressures were measured immediately after insertion and inflation of a No. 4 laryngeal mask airway (LMA) and 30, 60, 90, and 120 minutes thereafter. The dogs were euthanized, and biopsy specimens from eight predetermined areas of the laryngopharynx in contact with LMA cuff were collected for light microscopic (LM) and scanning electron microscopic (SEM) examination. Results: Initial LMA cuff inflation in G1 and G2 resulted in intracuff pressures of 119 mm Hg +/- 4 mm Hg and 235 mm Hg +/- 13 mm Hg, respectively. Over a 2-hour period, the intracuff pressure decreased significantly in G1 (P < .001) and G2 (P < .01), and there was a significant difference between the groups over time (P < .001). The LM study of laryngopharyngeal mucosa in both groups showed mild congestion in the subepithelial layer. There were no differences between the groups (P > .10) or among the areas sampled (P > .10). In some areas of G2, the SEM study showed epithelial desquamation that was more intense than that in GI. Conclusions: the increase in LMA intracuff pressure caused only mild alterations in the laryngopharyngeal mucosa of the dog.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectivesTo evaluate the influence of implant size and configuration on osseointegration in implants immediately placed into extraction sockets.Material and methodsImplants were installed immediately into extraction sockets in the mandibles of six Labrador dogs. In the control sites, cylindrical transmucosal implants (3.3 mm diameter) were installed, while in the test sites, larger and conical (root formed, 5 mm diameter) implants were installed. After 4 months of healing, the resorptive patterns of the alveolar crest were evaluated histomorphometrically.ResultsWith one exception, all implants were integrated in mineralized bone, mainly composed of mature lamellar bone. The alveolar crest underwent resorption at the control as well as at the test implants. This resorption was more pronounced at the buccal aspects and significantly greater at the test (2.7 +/- 0.4 mm) than at the control implants (1.5 +/- 0.6 mm). However, the control implants were associated with residual defects that were deeper at the lingual than at the buccal aspects, while these defects were virtually absent at test implants.ConclusionsThe installment of root formed wide implants immediately into extraction sockets will not prevent the resorption of the alveolar crest. In contrast, this resorption is more marked both at the buccal and lingual aspects of root formed wide than at standard cylindrical implants.To cite this article:Caneva M, Salata LA, de Souza SS, Bressan E, Botticelli D, Lang NP. Hard tissue formation adjacent to implants of various size and configuration immediately placed into extraction sockets: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 885-895.doi: 10.1111/j.1600-0501.2010.01931.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To study the influence on the healing of soft and hard peri-implant tissues when implants of different sizes and configurations were installed into sockets immediately after tooth extraction.Material and methods: Transmucosal cylindrical implants, 3.3 mm in diameter in the control sites, and conical 5 mm in diameter in the test sites, were installed into the distal socket of the fourth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant test sites (conical; 3.8 mm) was more resorbed compared with the control sites (cylindrical; 1.6 mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the peri-implant mucosa was located more apically at the test compared with the control sites.Conclusion: The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level, if the distance between the implant surface and the outer contour of the alveolar crest is small.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37° C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550®) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550® denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II® reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II® reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner® material. Both hard chairside reline materials failed adhesively across Lucitone 550® denture base resin, in both periods of time. © 1999 Blackwell Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective - To investigate the use of the laryngeal mask airway (LMA) in dogs. Study Design - Prospective experimental study. Animals - Eight healthy adult mixed breed dogs weighing from 15 to 20 kg. Methods - The dogs were anesthetized with intravenous pentobarbital. An LMA was introduced after the induction of anesthesia and 1 L/min O2 plus 1 L/min air was delivered using a circle anesthetic system. Respiratory rate, tidal volume, arterial O2 saturation (pulse oximetry), end tidal CO2, inspired fraction of O2, pulse rate, and mean arterial blood pressure were measured after the insertion of the LMA and 30, 60, 90, and 120 minutes afterwards. Results - There were no changes in respiratory rate, tidal volume, arterial O2 saturation, and pulse rate during anesthesia. End tidal CO2 decreased significantly by the end of anesthesia and ventilation appeared satisfactory. Conclusions - An LMA appeared to be an alternative option to maintain the patency of the airway in dogs. Clinical Relevance - This device may allow safe maintenance of an airway in dogs when intubation is difficult or when it interferes with the procedure (eg, cervical myelography). ©Copyright 1999 by The American College of Veterinary Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cases of decorative and functional applications, chromium results in protection against wear and corrosion combined with chemical resistance and good lubricity. However, pressure to identify alternatives or to improve conventional chromium electroplating mechanical characteristics has increased in recent years, related to the reduction in the fatigue strength of the base material and to environmental requirements. The high efficiency and fluoride-free hard chromium electroplating is an improvement to the conventional process, considering chemical and physical final properties. One of the most interesting, environmentally safer and cleaner alternatives for the replacement of hard chrome plating is tungsten carbide thermal spray coating, applied by the high velocity oxy-fuel (HVOF) process. The aim of this study was to analyse the effects of the tungsten carbide thermal spray coating applied by the HP/HVOF process and of the high efficiency and fluoride-free hard chromium electroplating (in the present paper called 'accelerated'), in comparison to the conventional hard chromium electroplating on the AISI 4340 high strength steel behaviour in fatigue, corrosion, and abrasive wear tests. The results showed that the coatings were damaging to the AISI 4340 steel behaviour when submitted to fatigue testing, with the tungsten carbide thermal spray coatings showing the better performance. Experimental data from abrasive wear tests were conclusive, indicating better results from the WC coating. Regarding corrosion by salt spray test, both coatings were completely corroded after 72 h exposure. Scanning electron microscopy technique (SEM) and optical microscopy were used to observe crack origin sites, thickness and adhesion in all the coatings and microcrack density in hard chromium electroplatings, to aid in the results analysis. © 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.