1000 resultados para Gerencia : Energia eletrica
Resumo:
This work has the purpose to explain how the sugar and alcohol sector works, detail all the processes which uses pumps and assist in the selection and specification of pumps attached with engines, that will make part in important industry processes in the manufacture of sugar and alcohol. A bibliographic revision about the working of sugar and alcohol sector and about pumps were made to help the analysis of a case. This case had the purpose to analyze the selected pumps that were part of a initial project of an industry which aimed a future expansion. The pumps that were selected to made part of the initial project were over dimensioned and were operating out of the best performance point, making the pumps inefficient because the expansion didn't happened. The solution was to select another pump with bigger performance and less power consumption to have a decrease in the energy consumption and in the operational costs of the industry and using the extra electric energy in the industry or selling it
Resumo:
Increasingly the business for large companies tend to sustainable actions. Such actions may have motivated social, environmental and economical too. Thus, the study of small actions or investments aimed at improving a product or a process may impact on financial return and even the exposure of a sustainable paper company, a fact that is increasingly wel l regarded in the market. This study presents proposals raised in the market and in the literature showing the cost of each investment, the payback over time and the benefits of each project to be implemented in a corporative building located in the city of São Paulo. It was analyzed the energy consumption, determining the amount of consumption of each device through measurement of some parameters such as voltage and operating current, and lifting nominal values supplied by the manufacturers. By understanding the conditions of each equipment and the processes involved, were raised possible energy improvements, focusing on the cooling system of the building, the tariff system and the installation of an energy management system
Resumo:
Energy efficiency has gained significant importance in recent years, mainly due to cyclical climatic conditions and current supply of natural resources. The present work deals with the procedures and requirements necessary to evaluate a building to a level of efficiency corresponding to your project and the actual implemented. To perform this analysis, we adopted the technical regulation efficiency prepared by Procel along with other agencies of the sector. The Regulation aims to create a model for the technical evaluation of the efficiency of buildings, popularize and expand the theme specification of conditions drawn up today. The building analyzed in this study was the library of UNESP, Guaratinguetá. Still, after the completion of the final efficiency analysis, are presented proposals for intervention that can improve and enhance the present situation of the building. The interventions are based on many technical factors and local conditions of climate and supply of resource. The issue of sustainability was explained in order to serve as a tool to expand the options available to upgrade a building in front of their impact on the environment
Resumo:
Smart grids are the focus of major study today because of the necessity of modernization in electrical systems and reduction of greenhouse gas emissions that increases global warming. Reaching the best deployment method, you must first of all know the current electrical system and how to use them for the benefit of this new technology. Preparing the action plan we should be aware of the main points of smart grids in each step of the electricity system - generation, transmission and distribution. Analyzed these topics, this work will focus on the first step in the implementation of the smart grids: the smart meters, tool which is already being implemented in Brazil. The main characteristics and applications of these devices, as well as their communication structure with the core distributors will be showed during the paper. Finally, we present a case study which will be discussed and analyzed based in the results obtained with the implementation of smart meters in the city of Vancouver, Canada, where we have a considerable savings already in the first year, with fully paying the initial investment and still have a profit
Resumo:
Atmospheric Discharges are responsible for several lost in the electrical system therefore it´s done studies to find ways to reduce the problem caused by discharges. This branch of engineering is necessary the gathering, stock and analysis of large quantity of data to validate or refuse the many studies produced about it The CENDAT proposed a project to collect data on induced voltages in distribution lines and current waveform of the lightning, but a difficulty that arose was the accumulation of data due to lack of manpower available to catalog all the data collected. Thinking in this difficulty, the engineer Acacio Silva Neto CENDAT´s researcher with trainees began to develop a program to solve this problem. This work keeps the development of this program in order to solve the problem of accumulation of data
Resumo:
In wood processing industries, which use electrical equipment in the production process, in most cases these are badly scaled or operate under inadequate conditions, resulting directly in industrial energy efficiency, which proves important because besides having technological innovation, also with practices and policies, aims to decrease power consumption. So in a wiring project should take into account the variables that influence energy efficiency. Thus this work has been reviewed and subsequently calculated some of these variables, such as active power, power factor and demand for the entire industry (global) and also for specific equipment, the chipper. The network analysis was performed in a wood processing industry in the city of Taquarivaí - SP, and evaluated these variables with a network analyzer and also by analysis on energy bills, which were found in both analysis levels below those found in literature. These factors are due to poor design, improper use, storage of equipment or even by characteristic of the production process, ie, the equipment running on empty because of the volatility of production
Resumo:
The discussions about the energy rationalization are gaining more and more space on the everyday of engineers and other professionals in the field of energy. A greater focus is being tied to commercial buildings, because they are one of the biggest responsible for the high energetic expenditure according to the National Energetic Balance, especially by the use of air conditioners for the people’s thermal comfort. Such finding made INMETRO to develop a building labeling procedure through th National Program of Electric Energy Conservation in Buildings; by means of this systematic, the built areas are classified by levels that go from A(the best) to E(the worst), taking into account envelopment, illumination system and air conditioning. A bonus process based on water rationalization, use of renewable energy sources, cogeneration systems or technical innovations, allows the classification to be changed up to one level. A study made exactly on a commercial building, the building of Foundation for Technological and Scientific Development located inside of the College of Engineering of Guaratinguetá, sought to identify technical/economic alternatives for the building certification and appealed to the bonus based on water rationalization. The present study is based on analysis of deploying a cogeneration system formed by internal combustion engine and an absorption refrigeration system as bonus alternative, so that the costs are analyzed regarding energy consumption and use of the motor. With the calculations and results, the viability of the building to receive a bonus from INMETRO through its National Program for Energy Conservation in Buildings is studied and concluded from this study whether or not you can get a better level of energy efficiency for the building in question... (Complete abstract click electronic access below)
Resumo:
The increase in energy consumption in the world has caused the electrical systems becoming ever larger and more complex. Because of that becomes necessary to use special tools to efficiently manage the equipment present in these systems. Nowadays a tool very used is the remote monitoring of assets which works collecting signals using sensors processing these signals and make them available to the system user. So the user can use informations that may assist him efficiently in making decisions when doing a maintenance. The system is technically efficient since it improves the measurement process and enables the asset management of a substation by using advanced technology for that and economically viable especially in cases where the user is subject to monetary loss due an interruption of power supply
Resumo:
The biomass gasification systems have been used for a long time and prove to be a good alternative to the generation of energy problems. This type of management requires a simple installation and maintenance which gives them a high availability. In Biomass project via Call CTEnerg 33/2006-1, funded by the Ministry of Science and Technology - MCT - Brazil, the Group Energy Systems Optimization – GOSE - at FEG - UNESP built and tested two prototypes of gasifiers. These is fed with 25 kg / h of dry wood (chips), and 50 Nm3 / h of air to produce gas at a flow rate of approximately 70 Nm3 / h of wood (syngas) at a temperature approximately 600 ° C. In this work of graduation, studies were conducted on the materials used in both the gasifier as well as cleaning the filter synthesis gases. The system of gas cleaning and conditioning is vital to ensure the life of the Internal Combustion Engine. In this case the studies of different filters for small gasification systems (properties, materials used, characteristics, types, etc.) are very relevant to its use in the prototype of the college campus. Were also performed a technical and economic analysis of a cogeneration system that consists in the combination of the downdraft gasifier studied in this work, an internal combustion engine, two heat exchangers and a SRA (absorption system refrigerator). Were calculated the costs of electricity generation, hot water and cold water. Finally, we analyzed the economic feasibility of the project
Resumo:
The search for energy efficiency improvement is a common concern in many companies. Cogeneration is a well known technique but not so spread in Brazil, despite its potential for energy costs reduction through heat recovery from prime movers. In this work, a preliminary technical and economic study is carried out for a cogeneration plant application in an automotive industry of São Paulo. Though mathematics modeling, three 2435 kW internal combustion engines are selected. When compared to the current status (no cogeneration), annual savings of about 2,2 MR$ are obtained, resulting a almost 3 years payback
Resumo:
This work contemplates an opportunities study of the rational use of energy in an industrial unity from the demand analysis and electrical energy consumption. Through a guide of energy analysis it was described how to find the main problems that create energy wastes in an industry, showing the ways so the production processes avoid such wastes and start to use energy in a more sensible e efficient way. It was also studied, the technical e economical viability of possible interventions to be implemented in terms of energy conservation and of possible demand supply alternatives
Resumo:
In this paper are compared two methods of deploying electrical substations, conventional type, when installed at open areas (Air Insulated Switchgear - AIS), and compact gas-insulated (Gas Insulated Switchgear - GIS) when installed inside buildings. With the expansion of urban centers, areas available for deployment of conventional substations become increasingly difficult to find in these locations. Also due to speculation in urban areas, it becomes feasible to install Gas Insulated Switchgear. This paper presents and evaluates criteria with advantages and disadvantages for application of the two methodologies, aiming to assist in decisionmaking moment of choice in deployment of Electric Power Substations in two scenarios. It is expected that at the end of this work, the criteria evaluated assist in this decision making
Resumo:
The aim of this work is to make a qualitatively and ecologically evaluation of a compact cogeneration system that operates with synthesis gas obtained from a gasifier. Using the Eucalyptus Biomass as fuel, that passes through a wood gasifier (Drowndraft type) and supply the internal combustion engine. The compact cogeneration system is composed of two heat exchangers, an energy generator connected to an internal combustion engine and an absorption refrigeration system. The complete system is installed in the laboratory from the Energy Department at the University of Guaratinguetá. By the analysis related to the First and Second Thermodynamic Laws applied in this system, was possible to identify the mass flows in each point, energetic efficiency, irreversibility and exergetic efficiency. The components that have the biggest irreversibilities are the gasifier, followed by the internal combustion engine, which should be focused in future improvements. The system efficiency in energetic basis is 51,84% and in exergetic basis is 22,78%. Using the ecologic efficiency methodology was possible to identify the emissions rates, the pollution indicator associated to the combustion of the synthesis gas in the internal combustion engine. The ecologic efficiency considering the energectic analysis is 91,73%, while considering the exergetic analysis, 83,65%. It is concluded that the use of the synthesis gas in a compact cogeneration system is viable from the technical and ecological point of view, making possible to generate energy for isolated communities and promoting the decentralized electricity generation
Resumo:
The proposed of scanning of an electrical industrial substation HV is associated with a segment of the Electrotechnical area and aims the study and preliminary application of digital technologies in the protection, control, measurement and automation maneuvers aimed at a Industrial Electrical System typical High Voltage. Well intended to supervision, protection and control of major electrical and thermal quantities involved in a substation, such as voltage levels, current, temperature, power factor, loads of transformers and circuit feeders, status of interlocking devices, switching equipment maneuvers, etc
Comissionamento de turbinas hidráulicas: ensaios de faixa operativa, índex, test e rejeição de carga
Resumo:
With growing electricty demand, the importance of generation through hydropower, a renewable energy source, it’s of great importance. This demand derives from the country’s growth, as well as events that will occur in the coming years. The commission has a crucial role before the entry into operation of hydroelectric plant, sice, ensures a good operation of hydraulic and electrical systems, as well as the safety of the installation. This paper is a case study, commissioning in a PCH in especially the most important tests, such as range operation, índex tes and load rejection. In these trials we can get a Idea of the actual behavior of the unit, as well as future operation maneuvers, and evidence of real efficiency