968 resultados para Fixed prosthesis
Resumo:
BACKGROUND: In alcohol withdrawal, fixed doses of benzodiazepine are generally recommended as a first-line pharmacologic approach. This study determines the benefits of an individualized treatment regimen on the quantity of benzodiazepine administered and the duration of its use during alcohol withdrawal treatment. METHODS: We conducted a prospective, randomized, double-blind, controlled trial including 117 consecutive patients with alcohol dependence, according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, entering an alcohol treatment program at both the Lausanne and Geneva university hospitals, Switzerland. Patients were randomized into 2 groups: (1) 56 were treated with oxazepam in response to the development of signs of alcohol withdrawal (symptom-triggered); and (2) 61 were treated with oxazepam every 6 hours with additional doses as needed (fixed-schedule). The administration of oxazepam in group 1 and additional oxazepam in group 2 was determined using a standardized measure of alcohol withdrawal. The main outcome measures were the total amount and duration of treatment with oxazepam, the incidence of complications, and the comfort level. RESULTS: A total of 22 patients (39%) in the symptom-triggered group were treated with oxazepam vs 100% in the fixed-schedule group (P<.001). The mean oxazepam dose administered in the symptom-triggered group was 37.5 mg compared with 231.4 mg in the fixed-schedule group (P<.001). The mean duration of oxazepam treatment was 20.0 hours in the symptom-triggered group vs 62.7 hours in the fixed-schedule group (P<.001). Withdrawal complications were limited to a single episode of seizures in the symptom-triggered group. There were no differences in the measures of comfort between the 2 groups. CONCLUSIONS: Symptom-triggered benzodiazepine treatment for alcohol withdrawal is safe, comfortable, and associated with a decrease in the quantity of medication and duration of treatment.
Resumo:
55 patients, scheduled to undergo total knee replacement, were randomized to receive either fixed or mobile-bearings. The results from a 5 year follow-up indicated that elderly patients (>70 years of age) with fixed bearings had better improvements in gait parameters in comparison to those with mobile bearings. These results was in fact reversed for patients less than 70 years of age, as they performed best with mobile bearings.
Resumo:
OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.
Resumo:
Background: Variable definitions of outcome (Constant score, Simple Shoulder Test [SST]) have been used to assess outcome after shoulder treatment, although none has been accepted as the universal standard. Physicians lack an objective method to reliably assess the activity of their patients in dynamic conditions. Our purpose was to clinically validate the shoulder kinematic scores given by a portable movement analysis device, using the activities of daily living described in the SST as a reference. The secondary objective was to determine whether this device could be used to document the effectiveness of shoulder treatments (for glenohumeral osteoarthritis and rotator cuff disease) and detect early failures.Methods: A clinical trial including 34 patients and a control group of 31 subjects over an observation period of 1 year was set up. Evaluations were made at baseline and 3, 6, and 12 months after surgery by 2 independent observers. Miniature sensors (3-dimensional gyroscopes and accelerometers) allowed kinematic scores to be computed. They were compared with the regular outcome scores: SST; Disabilities of the Arm, Shoulder and Hand; American Shoulder and Elbow Surgeons; and Constant.Results: Good to excellent correlations (0.61-0.80) were found between kinematics and clinical scores. Significant differences were found at each follow-up in comparison with the baseline status for all the kinematic scores (P < .015). The kinematic scores were able to point out abnormal patient outcomes at the first postoperative follow-up.Conclusion: Kinematic scores add information to the regular outcome tools. They offer an effective way to measure the functional performance of patients with shoulder pathology and have the potential to detect early treatment failures.Level of evidence: Level II, Development of Diagnostic Criteria, Diagnostic Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.
Resumo:
null
Resumo:
A stochastic nonlinear partial differential equation is constructed for two different models exhibiting self-organized criticality: the Bak-Tang-Wiesenfeld (BTW) sandpile model [Phys. Rev. Lett. 59, 381 (1987); Phys. Rev. A 38, 364 (1988)] and the Zhang model [Phys. Rev. Lett. 63, 470 (1989)]. The dynamic renormalization group (DRG) enables one to compute the critical exponents. However, the nontrivial stable fixed point of the DRG transformation is unreachable for the original parameters of the models. We introduce an alternative regularization of the step function involved in the threshold condition, which breaks the symmetry of the BTW model. Although the symmetry properties of the two models are different, it is shown that they both belong to the same universality class. In this case the DRG procedure leads to a symmetric behavior for both models, restoring the broken symmetry, and makes accessible the nontrivial fixed point. This technique could also be applied to other problems with threshold dynamics.
Resumo:
BACKGROUND: Artemisinin-based combination therapy (ACT) has been promoted as a means to reduce malaria transmission due to their ability to kill both asexual blood stages of malaria parasites, which sustain infections over long periods and the immature derived sexual stages responsible for infecting mosquitoes and onward transmission. Early studies reported a temporal association between ACT introduction and reduced malaria transmission in a number of ecological settings. However, these reports have come from areas with low to moderate malaria transmission, been confounded by the presence of other interventions or environmental changes that may have reduced malaria transmission, and have not included a comparison group without ACT. This report presents results from the first large-scale observational study to assess the impact of case management with ACT on population-level measures of malaria endemicity in an area with intense transmission where the benefits of effective infection clearance might be compromised by frequent and repeated re-infection. METHODS: A pre-post observational study with a non-randomized comparison group was conducted at two sites in Tanzania. Both sites used sulphadoxine-pyrimethamine (SP) monotherapy as a first-line anti-malarial from mid-2001 through 2002. In 2003, the ACT, artesunate (AS) co-administered with SP (AS + SP), was introduced in all fixed health facilities in the intervention site, including both public and registered non-governmental facilities. Population-level prevalence of Plasmodium falciparum asexual parasitaemia and gametocytaemia were assessed using light microscopy from samples collected during representative household surveys in 2001, 2002, 2004, 2005 and 2006. FINDINGS: Among 37,309 observations included in the analysis, annual asexual parasitaemia prevalence in persons of all ages ranged from 11% to 28% and gametocytaemia prevalence ranged from <1% to 2% between the two sites and across the five survey years. A multivariable logistic regression model was fitted to adjust for age, socioeconomic status, bed net use and rainfall. In the presence of consistently high coverage and efficacy of SP monotherapy and AS + SP in the comparison and intervention areas, the introduction of ACT in the intervention site was associated with a modest reduction in the adjusted asexual parasitaemia prevalence of 5 percentage-points or 23% (p < 0.0001) relative to the comparison site. Gametocytaemia prevalence did not differ significantly (p = 0.30). INTERPRETATION: The introduction of ACT at fixed health facilities only modestly reduced asexual parasitaemia prevalence. ACT is effective for treatment of uncomplicated malaria and should have substantial public health impact on morbidity and mortality, but is unlikely to reduce malaria transmission substantially in much of sub-Saharan Africa where individuals are rapidly re-infected.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Recent guidelines recommend initiation of antihypertensive therapy with fixed-dose combinations in high-risk patients because such patients usually need two or more blood pressure (BP)-lowering agents in order to normalize their BP. Agents that block the renin-angiotensin system (ACE inhibitors or angiotensin II receptor antagonists [angiotensin receptor blockers; ARBs]) are preferred for the management of hypertension in most patients exhibiting subclinical target organ damage, or established cardiovascular or renal diseases. Unless contraindicated they should be one of the components of fixed-dose combinations, whereas the other component may be either a calcium channel antagonist or a thiazide diuretic. Fixed-dose combinations containing an ACE inhibitor or ARB plus a calcium channel antagonist appear particularly effective in preventing complications of coronary heart disease.
Resumo:
Epistatic effects involving genic combinations of fixed and non fixed genes are shown to contribute to the genotypic mean of any population. These effects define specific additive x additive and additive x dominant epistatic components. As such components are not estimable, their relative importance cannot be assessed. These epistatic effects can cause bias in the estimates of the additive and dominance components to which they are confounded. The magnitude of the bias depends on the relative values of the epistatic effects, comparatively to deviations d and h, type of prevailing epistasis and direction of dominance.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.
Resumo:
Intraclass correlation (ICC) is an established tool to assess inter-rater reliability. In a seminal paper published in 1979, Shrout and Fleiss considered three statistical models for inter-rater reliability data with a balanced design. In their first two models, an infinite population of raters was considered, whereas in their third model, the raters in the sample were considered to be the whole population of raters. In the present paper, we show that the two distinct estimates of ICC developed for the first two models can both be applied to the third model and we discuss their different interpretations in this context.