926 resultados para Fire Safety engineering, FSE, ingegneria antincendio, prevenzione incnedi, evacuazione.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analysis of the structure of flame balls encountered under microgravity conditions, which are stable due to radiant energy losses from H₂O, is carried out for fuel-lean hydrogen-air mixtures. It is seen that, because of radiation losses, in stable flame balls the maximum flame temperature remains close to the crossover temperature, at which the rate of the branching step H + O₂ -> OH + O equals that of the recombination step H + O₂ + M -> HO₂ + M. Under those conditions, all chemical intermediates have very small concentrations and follow the steady-state approximation, while the main species react according to the overall step 2H₂ + O₂-> 2H₂O; so that a one-step chemical-kinetic description, recently derived by asymptotic analysis for near-limit fuel-lean deflagrations, can be used with excellent accuracy to describe the whole branch of stable flame balls. Besides molecular diffusion in a binary-diffusion approximation, Soret diffusion is included, since this exerts a nonnegligible effect to extend the flammability range. When the large value of the activation energy of the overall reaction is taken into account, the leading-order analysis in the reaction-sheet approximation is seen to determine the flame ball radius as that required for radiant heat losses to remove enough of the heat released by chemical reaction at the flame to keep the flame temperature at a value close to crossover. The results are relevant to burning velocities at lean equivalent ratios and may influence fire-safety issues associated with hydrogen utilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"DOE/EV-0092."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sarawak, Malaysia has a large population of ethnic minorities who live in longhouses in remote rural areas where poverty, non-communicable diseases, accidents and injuries, environmental hazards and communicable diseases all contribute to a lower quality of life than is possible to achieve in these regions. To address these issues and improve the quality of life for longhouse people, the Kapit Divisional Health Office implemented the World Health Organization's Healthy Village programme in 2000. An evaluation was undertaken in 2003 to determine physical and behavioural changes resulting from the programme. The main changes evaluated were those involving smoking habits, exercise habits, health screening, fire safety, environmental improvements and food preparation and hygiene. A qualitative evaluation was conducted using participant observation and key-informant interviews, focus groups and observation. Results indicate that the programme is inspiring changes in various behavioural and physical characteristics of the study population. It is clear that the Healthy Village programme is a widely accepted way of improving health outcomes in longhouses, and that it is succeeding in making beneficial health changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The great demand for Federal Institutions of High Education (IFES) design, triggered by the favourable political moment, boosts the public works market and brings with it the stigma of seeking the lowest cost and meet the federal Law 8.666/93 (Bids). In this context, this research makes an analysis of compliance with Fire Safety’s normative requirements in IFES’s architectural designs, taking this point as an evaluation of quality of designs. For the study, were used, IFES’s designs, specifically from UFERSA – Universidade Federal Rural do Semiárido and UFRN – Universidade Federal do Rio Grande do Norte, selected by the relationship use x public served and yet, in the replication of these buildings’ construction. The research was developed through the identification of the Fire Safety applicable legislation to the designs in question, with the determination of the demanded conditions that are architect’s autonomy or that affect the architectural design. Tabulated the requirements, through data collection and measures gathered in the blueprints, was made a comparison and verification of the compliance with these. The results of this evaluation reveal that the minimum requirements was not fulfilled and that IFES’s architectural designs, taken as object in this study, certainly will suffer restrictions in their regularization process with the Fire Department. It is concluded that is necessary an improvement in the IFES’s designs to meet the minimum fire safety regulations and improvement in quality. Moreover, the results direct to the understanding that level of knowledge about Fire Safety received in undergraduate by architects is insufficient for appropriate elaboration of architectural designs in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room’s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flame retardants (FRs) are added to materials to enhance the fire safety level of readily combustible polymers. Although they have been purported to aid in preventing fires in some cases, they have also become a significant cause for concern given the vast data on environmental persistence and human and animal adverse health effects. Evidence since the 1980s has shown that Canadian, American and Europeans have detectable levels of FRs in their bodies. North Americans in particular have high levels of these chemicals due to stringent flammability standards and the higher use of polybrominated diphenyl ethers (PBDEs) in North America as opposed to Europe. FRs have been detected in household dust and some evidence suggests that TVs could be a significant source of exposure to FRs. It is imperative to re-visit the flammability standard (UL94V) that allows for FR use in TVs plastic materials by providing a risk versus benefit analysis to determine if this standard provides a fire safety benefit and if it plays a major role in FR exposure. This report first examined the history of televisions and the progression to the UL94V flammability test standard to understand why FRs were first added to polymers used in the manufacturing of TVs. It has been demonstrated to be due to fire hazards resulting from the use of plastic materials in cathode-ray tube (CRT) TVs that had an “instant-on” feature and high voltage and operating temperatures. In providing a risk versus benefit analysis, this paper presents the argument that 1) by providing a market survey the current flammability test standard (UL94V) is outdated and lacks relevance to current technology as flat, thin, energy efficient Liquid Crystal Displays (LCDs) dominate over traditionally used heavy, bulky and energy-intensive CRTs; 2) FRs do not impart fire safety benefits considering that there is a lack of valid fire safety concern, such as reduced internal and external ignition and fire hazard, and a lack of valid fire data and hazard for television fires in general and finally; 3) the standard is overly stringent as it does not consider the risk due to exposure to FRs in household dust due to the proliferation and greater use of televisions in households. Therefore, this report argues that the UL94V standard has become trapped in history and needs to be updated as it may play a major role in FR exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los sistemas de alarmas constituyen un elemento clave en las plantas modernas de procesos industriales. A lo largo de los años, los mismos han ido evolucionando de la mano del importante desarrollo en la industria del software, para pasar de ser simples paneles de anunciación y lámparas cableadas hasta complejos sistemas inteligentes que asisten al operador en sus funciones de operación. En el desarrollo de este trabajo se planteó diseñar un Sistema Avanzado de Alarmas para el Reactor Nuclear de Investigación RA6 contemplando las nuevas tecnologías existentes para incorporar mejoras a la actual sala de control. Para ello se trabajó siguiendo la metodología propuesta por la guía de diseño de sistemas de alarmas ANSI / ISA- SP-18. Para asistir al diseño y la verificación del sistema se utilizó un modelo termohidráulico de la planta desarrollado en Matlab/Simulink. Entre las nuevas herramientas incorporadas en el prototipo final obtenido se pueden mencionar: creación de archivos históricos, asignación de prioridades, supresiones de alarmas según estado operativo, filtrado y agrupamiento de alarmas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using product and system design to influence user behaviour offers potential for improving performance and reducing user error, yet little guidance is available at the concept generation stage for design teams briefed with influencing user behaviour. This article presents the Design with Intent Method, an innovation tool for designers working in this area, illustrated via application to an everyday human–technology interaction problem: reducing the likelihood of a customer leaving his or her card in an automatic teller machine. The example application results in a range of feasible design concepts which are comparable to existing developments in ATM design, demonstrating that the method has potential for development and application as part of a user-centred design process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los sistemas de alarmas constituyen un elemento clave en las plantas modernas de procesos industriales. A lo largo de los años, los mismos han ido evolucionando de la mano del importante desarrollo en la industria del software, para pasar de ser simples paneles de anunciación y lámparas cableadas hasta complejos sistemas inteligentes que asisten al operador en sus funciones de operación. En el desarrollo de este trabajo se planteó diseñar un Sistema Avanzado de Alarmas para el Reactor Nuclear de Investigación RA6 contemplando las nuevas tecnologías existentes para incorporar mejoras a la actual sala de control. Para ello se trabajó siguiendo la metodología propuesta por la guía de diseño de sistemas de alarmas ANSI / ISA- SP-18. Para asistir al diseño y la verificación del sistema se utilizó un modelo termohidráulico de la planta desarrollado en Matlab/Simulink. Entre las nuevas herramientas incorporadas en el prototipo final obtenido se pueden mencionar: creación de archivos históricos, asignación de prioridades, supresiones de alarmas según estado operativo, filtrado y agrupamiento de alarmas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A systematic study was conducted to elucidate the effects of acoustic perturbations on laminar diffusion line-flames and the conditions required to cause acoustically-driven extinction. Flames were produced from the fuels n-pentane, n-hexane, n-heptane, n-octane, and JP-8, using fuel-laden wicks. The wicks were housed inside of a burner whose geometry produced flames that approximated a two dimensional flame sheet. The acoustics utilized ranged in frequency between 30-50 Hz and acoustic pressures between 5-50 Pa. The unperturbed mass loss rate and flame height of the alkanes were studied, and they were found to scale in a linear manner consistent with Burke-Schumann. The mass loss rate of hexane-fueled flames experiencing acoustic perturbations was then studied. It was found that the strongest influence on the mass loss rate was the magnitude of oscillatory air movement experienced by the flame. Finally, acoustic perturbations were imposed on flames using all fuels to determine acoustic extinction criterion. Using the data collected, a model was developed which characterized the acoustic conditions required to cause flame extinction. The model was based on the ratio of an acoustic Nusselt Number to the Spalding B Number of the fuel, and it was found that at the minimum speaker power required to cause extinction this ratio was a constant. Furthermore, it was found that at conditions where the ratio was below this constant, a flame could still exist; at conditions where the ratio was greater than or equal to this constant, flame extinction always occurred.