818 resultados para Fiber Optic Sensors in Quality evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of ultra-thin films as dressings for cutaneous wounds could prove advantageous in terms of better conformity to wound topography and improved vapour transmission. For this purpose, ultra-thin poly(epsilon-caprolactone) (PCL) films of 5-15 microm thickness were fabricated via a biaxial stretching technique. To evaluate their in vivo biocompatibility and feasibility as an external wound dressing, PCL films were applied over full and partial-thickness wounds in rat and pig models. Different groups of PCL films were used: untreated, NaOH-treated, untreated with fibrin, NaOH-treated with perforations, and NaOH-treated with fibrin and S-nitrosoglutathione. Wounds with no external dressings were used as controls. Wound contraction rate, histology and biomechanical analyses were carried out. Wounds re-epithelialized completely at a comparable rate. Formation of a neo-dermal layer and re-epithelialization were observed in all the wounds. A lower level of fibrosis was observed when PCL films were used, compared to the control wounds. Ultimate tensile strength of the regenerated tissue in rats reached 50-60% of that in native rat skin. Results indicated that biaxially-stretched PCL films did not induce inflammatory reactions when used in vivo as a wound dressing and supported the normal wound healing process in full and partial-thickness wounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smart matrices are required in bone tissueengineered grafts that provide an optimal environment for cells and retain osteo-inductive factors for sustained biological activity. We hypothesized that a slow-degrading heparin-incorporated hyaluronan (HA) hydrogel can preserve BMP-2; while an arterio–venous (A–V) loop can support axial vascularization to provide nutrition for a bioartificial bone graft. HA was evaluated for osteoblast growth and BMP-2 release. Porous PLDLLA–TCP–PCL scaffolds were produced by rapid prototyping technology and applied in vivo along with HA-hydrogel, loaded with either primary osteoblasts or BMP-2. A microsurgically created A–V loop was placed around the scaffold, encased in an isolation chamber in Lewis rats. HA-hydrogel supported growth of osteoblasts over 8 weeks and allowed sustained release of BMP-2 over 35 days. The A–V loop provided an angiogenic stimulus with the formation of vascularized tissue in the scaffolds. Bone-specific genes were detected by real time RT-PCR after 8 weeks. However, no significant amount of bone was observed histologically. The heterotopic isolation chamber in combination with absent biomechanical stimulation might explain the insufficient bone formation despite adequate expression of bone-related genes. Optimization of the interplay of osteogenic cells and osteo-inductive factors might eventually generate sufficient amounts of axially vascularized bone grafts for reconstructive surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article focuses on the evaluation of thesis supervision and highlights the vast range of problem areas presently documented as significant areas of concern for both graduate students and their supervisors. Additionally, the authors report on a study completed in 1995, which surveyed all Australian universities about current evaluative practices in postgraduate supervision. The conclusion of this study was that the conduct of such evaluations appears to be minimal and is primarily designed to obtain an indicator of the general “health” of a university's postgraduate supervision rather than to foster improved supervisory practices. As part of the same study, the authors conducted University faculty-based student and supervisor focus groups. Key issues emerging from these focus groups were: (1) the importance of relational aspects of supervision as the student communicates over the long term with one or more supervisors; (2) the importance of systematic feedback, monitoring, and evaluation to the supervisory process; and (3) the lack of strategies to facilitate this evaluative feedback process. On the basis of these findings, the authors designed evaluative strategies to facilitate regular ongoing feedback between students and supervisors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fibrous scaffolds of engineered structures can be chosen as promising porous environments when an approved criterion validates their applicability for a specific medical purpose. For such biomaterials, this paper sought to investigate various structural characteristics in order to determine whether they are appropriate descriptors. A number of poly(3-hydroxybutyrate) scaffolds were electrospun; each of which possessed a distinguished architecture when their material and processing conditions were altered. Subsequent culture of mouse fibroblast cells (L929) was carried out to evaluate the cells viability on each scaffold after their attachment for 24 h and proliferation for 48 and 72 h. The scaffolds’ porosity, pores number, pores size and distribution were quantified and none could establish a relationship with the viability results. Virtual reconstruction of the mats introduced an authentic criterion, “Scaffold Percolative Efficiency” (SPE), with which the above descriptors were addressed collectively. It was hypothesized to be able to quantify the efficacy of fibrous scaffolds by considering the integration of porosity and interconnectivity of the pores. There was a correlation of 80% as a good agreement between the SPE values and the spectrophotometer absorbance of viable cells; a viability of more than 350% in comparison to that of the controls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: This paper describes the development of a risk adjustment (RA) model predictive of individual lesion treatment failure in percutaneous coronary interventions (PCI) for use in a quality monitoring and improvement program. Methods and results: Prospectively collected data for 3972 consecutive revascularisation procedures (5601 lesions) performed between January 2003 and September 2011 were studied. Data on procedures to September 2009 (n = 3100) were used to identify factors predictive of lesion treatment failure. Factors identified included lesion risk class (p < 0.001), occlusion type (p < 0.001), patient age (p = 0.001), vessel system (p < 0.04), vessel diameter (p < 0.001), unstable angina (p = 0.003) and presence of major cardiac risk factors (p = 0.01). A Bayesian RA model was built using these factors with predictive performance of the model tested on the remaining procedures (area under the receiver operating curve: 0.765, Hosmer–Lemeshow p value: 0.11). Cumulative sum, exponentially weighted moving average and funnel plots were constructed using the RA model and subjectively evaluated. Conclusion: A RA model was developed and applied to SPC monitoring for lesion failure in a PCI database. If linked to appropriate quality improvement governance response protocols, SPC using this RA tool might improve quality control and risk management by identifying variation in performance based on a comparison of observed and expected outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the architecture of a monitoring component for the YAWL system. The architecture proposed is based on sensors and it is realized as a YAWL service to have perfect integration with the YAWL systems. The architecture proposed is generic and applicable in different contexts of business process monitoring. Finally, it was tested and evaluated in the context of risk monitoring for business processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although Design Science Research (DSR) is now an accepted approach to research in the Information Systems (IS) discipline, consensus on the methodology of DSR has yet to be achieved. Lack of a comprehensive and detailed methodology for Design Science Research (DSR) in the Information System (IS) discipline is a main issue. Prior research (the parent-study) aimed to remedy this situation and resulted in the DSR-Roadmap (Alturki et al., 2011a). Continuing empirical validation and revision of the DSR-Roadmap strives towards a methodology with appropriate levels of detail, integration, and completeness for novice researchers to efficiently and effectively conduct and report DSR in IS. The sub-study reported herein contributes to this larger, ongoing effort. This paper reports results from a formative evaluation effort of the DSR-Roadmap conducted using focus group analysis. Generally, participants endorsed the utility and intuitiveness of the DSR-Roadmap, while also suggesting valuable refinements. Both parent-study and sub-study make methodological contributions. The parent-study is the first attempt of utilizing DSR to develop a research methodology showing an example of how to use DSR in research methodology construction. The sub-study demonstrates the value of the focus group method in DSR for formative product evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Successful anatomic fitting of a total artificial heart (TAH) is vital to achieve optimal pump hemodynamics after device implantation. Although many anatomic fitting studies have been completed in humans prior to clinical trials, few reports exist that detail the experience in animals for in vivo device evaluation. Optimal hemodynamics are crucial throughout the in vivo phase to direct design iterations and ultimately validate device performance prior to pivotal human trials. In vivo evaluation in a sheep model allows a realistically sized representation of a smaller patient, for which smaller third-generation TAHs have the potential to treat. Our study aimed to assess the anatomic fit of a single device rotary TAH in sheep prior to animal trials and to use the data to develop a threedimensional, computer-aided design (CAD)-operated anatomic fitting tool for future TAH development. Following excision of the native ventricles above the atrio-ventricular groove, a prototype TAH was inserted within the chest cavity of six sheep (28–40 kg).Adjustable rods representing inlet and outlet conduits were oriented toward the center of each atrial chamber and the great vessels, with conduit lengths and angles recorded for future analysis. A threedimensional, CAD-operated anatomic fitting tool was then developed, based on the results of this study, and used to determine the inflow and outflow conduit orientation of the TAH. The mean diameters of the sheep left atrium, right atrium, aorta, and pulmonary artery were 39, 33, 12, and 11 mm, respectively. The center-to-center distance and outer-edge-to-outer-edge distance between the atria, found to be 39 ± 9 mm and 72 ± 17 mm in this study, were identified as the most critical geometries for successful TAH connection. This geometric constraint restricts the maximum separation allowable between left and right inlet ports of a TAH to ensure successful alignment within the available atrial circumference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis described the synthesis of an L-leucine conjugate of the biodegradable polymer, chitosan and its potential application for the development of controlled release nanoparticulate dry powder inhaler (DPI) formulations. The study demonstrated that the physicochemical properties of conjugated chitosan nanoparticles had favourable effects on the dispersibility and controlled release profile of a model drug. The toxicity profile of the nanoparticulate formulation revealed promising outcome for its use in pulmonary delivery. The chitosan conjugate produced in this project would be useful for the application of polymer nanoparticulate systems for efficient lung delivery of drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we propose a method that integrates the no- tion of understandability, as a factor of document relevance, into the evaluation of information retrieval systems for con- sumer health search. We consider the gain-discount evaluation framework (RBP, nDCG, ERR) and propose two understandability-based variants (uRBP) of rank biased precision, characterised by an estimation of understandability based on document readability and by different models of how readability influences user understanding of document content. The proposed uRBP measures are empirically contrasted to RBP by comparing system rankings obtained with each measure. The findings suggest that considering understandability along with topicality in the evaluation of in- formation retrieval systems lead to different claims about systems effectiveness than considering topicality alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Child behaviour management is crucial to successful treatment of atopic dermatitis. This study tested relationships between parents’ self-efficacy, outcome expectations, and self-reported task performance when caring for a child with atopic dermatitis. Using a cross-sectional study design, a community-based convenience sample of 120 parents participated in pilot-testing of the Child Eczema Management Questionnaire - a self-administered questionnaire which appraises parents’ self-efficacy, outcome expectations, and self-reported task performance when managing atopic dermatitis. Overall, parents’ self-reported confidence and success with performing routine management tasks was greater than that for managing their child’s symptoms and behaviour. Therewas a positive relationship between time since diagnosis and self-reported performance of routine management tasks; however, success with managing the child’s symptoms and behaviour did not improve with illness duration. Longer time since diagnosis was also associated with more positive outcome expectations of performing tasks that involved others in the child’s care (i.e. healthcare professionals, or the child themselves). This study provides the foundation for further research examining relationships between child, parent, and family psychosocial variables, parent management of atopic dermatitis, and child health outcomes. Improved understanding of these relationships will assist healthcare providers to better support parents and families caring for children with atopic dermatitis. KEYWORDS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Health care services are typically consumed out of necessity, typically to recover from illness. While the consumption of health care services can be emotional given that consumers experience fear, hope, relief, and joy, surprisingly, there is little research on the role of consumer affect in health care consumption. We propose that consumer affect is a heuristic cue that drives evaluation of health care services. Drawing from cognitive appraisal theory and affect-as-information theory, this article tests a research model (N = 492) that investigates consumer affect resulting from service performance on subsequent service outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.