440 resultados para Extrapolation
Resumo:
Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes: • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results. The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are: • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions. The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab. This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.
Resumo:
O objetivo do presente trabalho é analisar a plausividade da tese da mutação constitucional como mecanismo de efetivação da Constituição da República Federativa Brasil de 1988 e a partir dos 6 (seis) principais julgados do Supremo Tribunal Federal verificar se os limites impostos a esse fenômeno estão sendo respeitados. Com objetivo de comprovar esta tese foi estudado desde a opção do poder constituinte originário em atribuir aspecto rígido a Constituição pátria, permitindo que algumas matérias de seu texto através de mecanismos específicos possam ser alterados, até a legitimidade reflexa dos ministros do STF para atuarem como legisladores positivos alterando o sentido da norma sem modificação de seu conteúdo. A exposição dos limites impostos a mutação constitucional também foi alvo de especial destaque, pois somente a partir da compreensão destes seria possível uma análise sobre eventual extrapolação de competência do Poder Judiciário. A partir dos julgados do STF verificamos que a mutação constitucional está sendo aplicada dentro os limites impostos, logo este instituto atingiu seu objetivo central de aproximar as normas constitucionais a realidade da sociedade sem ferir o princípio da Separação de Poderes. Como resultado concluímos que a mutação constitucional a partir do cenário político atual que assume a asfixia e a consequente morosidade do Poder Legislativo, é um instrumento imprescindível para dar efetividade aos preceitos e princípios fundamentais da Constituição. Na atual conjuntura abdicar deste valioso instrumento seria o mesmo que assumir o fracasso e a inobservância de todo ordenamento jurídico, já que este não conseguirá reger as relações humanas da sociedade.
Resumo:
In recent years the heparin has been the subject of several studies that aim to expand its use as a therapeutic agent, due to its ability to modulate the activity of various proteins that play important roles in the regulation of pathophysiological processes. In several experiments and preclinical trials, heparin has demonstrated an anti-inflammatory role. However, its clinical use is limited, due to its strong anticoagulant activity and hemorrhagic complications. For this reason, considerable efforts have been employed in discovery of heparin analogous (heparinoid) with reduced side effects, that retain the anti-inflammatory properties of heparin. In this context, a heparinoid obtained from the head of Litopenaeus vannamei shrimp, which presents a structural similarity to heparin, showed, in previous studies, anti-inflammatory activity in a model of acute peritonitis with reduced anticoagulant effect in vitro and low hemorrhagic activity. Thus, the present work had as objective to evaluate the effect the heparinoid of the cephalothorax of gray shrimp on the acute inflammatory response in different times (3 or 6 hours after the induction of inflammatory stimulus), using the model of acute peritonitis induced in mice. It was also analyzed the HL effect over the activity of elastase, an enzyme involved in leukocyte recruitment. Furthermore to check if the different doses of heparin and heparinoid change the hemostatic balance in vivo, was assessed the effect of these compounds on the plasma clotting time in animals submitted to inflammation. The results show that in 3 hours, all doses of heparinoid were able to prevent efficiently in the acute inflammatory process without any anticoagulant effects, unlike the extrapolation dose of heparin, which has induced a large hemorrhage due its high anticoagulant activity. However, 6 hours after induction of inflammation, only the dosages of 0.1 and 1.0 μg/Kg of heparin and 1.0 μg/Kg of heparinoid kept anti-migratory effect, without changing of the hemostatic balance. These results indicate that the anti-migratory effect of theses compounds depends on the dosage and time of inflammatory stimulus. The HL and heparin were also able to inhibit the activity of the enzyme elastase. The discovery of this bioactive compound in the cephalothorax of shrimps can arouse great interest in biotechnology, since this compound could be useful as a structural model interesting for the development of new therapeutic agents for peritonitis
Resumo:
In the search for products that act as corrosion inhibitors and do not cause environmental, impact the use of plant extracts as corrosion inhibitors is becoming a promising alternative. In this work the efficiency of polar extracts (ethanol extracts) obtained from the plants Anacardium occidentale Linn (AO) and Phyllantus amarus Schum. & Thonn (PA) as corrosion inhibitors were evaluated in different concentrations. For that AO and PA extracts were solubilized in the microemulsion systems (SME) containing saponified coconut oil as surfactant (SME -OCS and SME-OCS-1) in saline (NaCl 3,5 %) solution, which was also used as electrolyte. Both SME-OCS and SME-OCS-1 were characterized by surface tension and viscosity methods showing a Newtonian fluid behavior. The SME-OCS and SME-OCS-1 systems satisfactorily solubilized the polar extracts AO and PA with measurements carried out by ultraviolet spectroscopy. The measurements of corrosion inhibition efficiencies were performed by the electrochemical linear polarization resistance (LPR) technique as well as weight loss, on the surface of AISI 1020 carbon steel. The maximum corrosion inhibition efficiencies were determined by extrapolation of Tafel plots, showing the following values: 95,6 % for the system SME-OCS-AO, 98,9 % for the system SME-OCS-AO-1 and 93,4 % for the system SME-OCS-PA
Resumo:
The increase in ultraviolet radiation (UV) at surface, the high incidence of non-melanoma skin cancer (NMSC) in coast of Northeast of Brazil (NEB) and reduction of total ozone were the motivation for the present study. The overall objective was to identify and understand the variability of UV or Index Ultraviolet Radiation (UV Index) in the capitals of the east coast of the NEB and adjust stochastic models to time series of UV index aiming make predictions (interpolations) and forecasts / projections (extrapolations) followed by trend analysis. The methodology consisted of applying multivariate analysis (principal component analysis and cluster analysis), Predictive Mean Matching method for filling gaps in the data, autoregressive distributed lag (ADL) and Mann-Kendal. The modeling via the ADL consisted of parameter estimation, diagnostics, residuals analysis and evaluation of the quality of the predictions and forecasts via mean squared error and Pearson correlation coefficient. The research results indicated that the annual variability of UV in the capital of Rio Grande do Norte (Natal) has a feature in the months of September and October that consisting of a stabilization / reduction of UV index because of the greater annual concentration total ozone. The increased amount of aerosol during this period contributes in lesser intensity for this event. The increased amount of aerosol during this period contributes in lesser intensity for this event. The application of cluster analysis on the east coast of the NEB showed that this event also occurs in the capitals of Paraiba (João Pessoa) and Pernambuco (Recife). Extreme events of UV in NEB were analyzed from the city of Natal and were associated with absence of cloud cover and levels below the annual average of total ozone and did not occurring in the entire region because of the uneven spatial distribution of these variables. The ADL (4, 1) model, adjusted with data of the UV index and total ozone to period 2001-2012 made a the projection / extrapolation for the next 30 years (2013-2043) indicating in end of that period an increase to the UV index of one unit (approximately), case total ozone maintain the downward trend observed in study period
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We have undertaken a comprehensive study of the NH3 + N2O3 reaction in gas phase. Total energies of reactants, intermediates, transition states, and products have been calculated at CBS-QB3 level of theory. The corresponding BSSE analysis were performed at the highest level of theory, i.e. MP2 using the complete basis set (CBS) extrapolation at CBS-QB3 optimized geometries. A detailed mechanism was proposed for 2NH(3) - N2O3 -> 2N(2) - 3H(2)O with Delta H-r= - 170.08 kcal/mol N-2. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Corrosion inhibitors in solution are utilized to minimize processes from corrosion in steel. Of the present dissertation was evaluated the efficiency by inhibition from the surfactant saponified coconut oil (OCS) in the carbon steel 1020 through in linear polarization electrochemistry technique, well as, studied the process from adsorption through from the isotherms from Langmuir, Frumkin and Temkin. The corrosion current was determined through in Tafel extrapolation from the curves in the polarization, and then, was calculated the efficiency in the inhibitor to each concentration and temperature. Were studied four concentrations (12,5 ppm, 25 ppm, 50 ppm, and 75 ppm) in the inhibitor OCS and one in the NaCl salt (10.000 ppm) in six temperatures (301 K, 308 K, 313 K, 318 K, 323 K, and 328 K) in triplicate. By the results obtained observed that the technique applied can evaluated with rapidity and efficiency corrosion inhibitors. In relation to the isotherms, the than best appropriated was the in Langmuir and in the concentrations studied, the that obtained the best efficiency was the concentration of 75 ppm
Resumo:
Corrosion is an important phenomenon that frequently occurs in the oil industry, causing surface ablation, such as it happens on the internal surfaces of oil pipes. This work aims to obtain new systems to reduce this specific problem. The surfactants SDS, CTAB, and UNITOL L90 (in micellar and microemulsionated systems) were used as corrosion inhibitors. The systems were obtained using a C/S ratio of 2, butanol as cosorfactant, kerosene as oil phase and, as water phase, NaCl solutions of 0.5M with pH = 2, 4, and 7. Microemulsion regions were found both for direct and inverse micelles. SDS had the higher microemulsion region and the area was not dependent of pH. The study of micellization of these surfactans in the liquid-gas interface was carried out via the determination of CMC from surface tension measurements. Regarding microemulsionated systems, in the case of CTAB, CMC increased when pH was increased, being constant for SDS and UNITOL L90. Concerning micellar systems, increase in pH caused decrease and increase in CMC for SDC and CTAB, respectively. In the case of UNITOL L90, CMC was practically constant, but increased for pH = 4. The microemulsionated systems presented higher CMC values, except for UNITOL L90 L90. The negative values of free energy of micellization indicated that the process of adsorption was spontaneous. The results also indicated that, comparing microemulsionated to systems, adsorption was less spontaneous in the case of SDS and CTAB, while it did not change for UNITOL L90. SAXS experiments indicated that micelle geometry was spherical, existing also as halter and flat micelles, resuting in a better inght on the adsorption at the liquid-solid interface. Efficiency of corrosion inhibition as determined by electrochemical measurements, from corrosion currents calculated from Tafel extrapolation indicuting heat showed surfactants to be efficient even at low concentrations. Equilibrium isotherm data were fitted to the Freundlich model, indicating that surfactant adsorption occurs in the form of multilayers
Resumo:
Nowadays, the use of chemicals that satisfactorily meet the needs of different sectors of the chemical industry is linked to the consumption of biodegradable materials. In this context, this work contemplated biotechnological aspects with the objective of developing a more environmentally-friendly corrosion inhibitor. In order to achieve this goal, nanoemulsion-type systems (NE) were obtained by varying the amount of Tween 80 (9 to 85 ppm) a sortitan surfactant named polyoxyethylene (20) monooleate. This NE-system was analyzed using phase diagrams in which the percentage of the oil phase (commercial soybean oil, codenamed as OS) was kept constant. By changing the amount of Tween 80, several polar NE-OS derived systems (O/W-type nanoemulsion) were obtained and characterized through light scattering, conductivity and pH, and further subjected to electrochemical studies. The interfacial behavior of these NE-OS derived systems (codenamed NE-OS1, S2, S3, S4 and S5) as corrosion inhibitors on carbon steel AISI 1020 in saline media (NaCl 3.5%) were evaluated by measurement of Open Circuit Potential (OCP), Polarization Curves (Tafel extrapolation method) and Electrochemical Impedance Spectroscopy (EIS). The analyzed NE-OS1 and NE-OS2 systems were found to be mixed inhibitors with quantitative efficacy (98.6% - 99.7%) for concentrations of Tween 80 ranging between 9 and 85 ppm. According to the EIS technique, maximum corrosion efficiency was observed for some tested NE-OS samples. Additionaly to the electrochemical studies, Analysis of Variance (ANOVA) and Principal Component Analysis (PCA) were used, characterization of the nanoemulsion tested systems and adsorption studies, respectively, which confirmed the results observed in the experimental analyses using diluted NE-OS samples in lower concentrations of Tween 80 (0.5 1.75 ppm)
Resumo:
The ichthyofauna of 24 stretches of streams, all of 100 m length and of fifth or lower order and most of second and third order, were sampled along four left bank tributaries (Rio do Peixe, Rio Aguapei, Rio Sao Jose dos Dourados, lower Rio Tiete of the main channel of the Rio Parana in the state of São Paulo, southeastern Brazil. Sampling of the fish fauna at each of the six sites in the four basins incorporated a standardized fish collecting methodology and a standardized documentation of environmental data serving as the basis for a comparative analysis of the collecting locations. The 8,189 fish specimens collected represented six orders, 18 families, 42 genera, and 56 species, with a total biomass of 28.8 kg. Approximately 52% of the collected species were characiforms, 28% siluriforms, 9% gymnotiforms, 5% cyprinodontiforms, 4% perciforms, and 2% synbranchiforms. The most abundant of the species were the characiforms Astyanax altiparanae (15% of total) and Knodus moenkhausii (12% of total). The two species with the largest overall biomasses were A. altiparanae (34% of total biomass) and the siluriform Hypostomus sp. (8% of total biomass). Analysis of the trophic structure of the studied ichthyofauna indicated that the 10 numerically dominant species across the 24 sampled streams can be grouped into five guilds that are in decreasing order of numerical importance: omnivores, insectivores, insectivores/invertivores, periphytivores, and algivores. Species richness in the sampled stream stretches varied from six to 20 species with an average richness of 14. The species richness estimated by extrapolation for all 24 sampled stream stretches was 67 species. The Characidae are predominant among the collected specimens with approximately 50% of both individuals and biomass, a fact hypothesized to be a function of several attributes typical of the family. Six of the 56 collected species were new to science and six other species are of indefinite taxonomic status and require further analysis in order to determine their identity.