944 resultados para ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY(ESI-MSn)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The unimolecular reactivities of a range of perbenzoate anions (X-C6H5CO3-), including the perbenzoate anion itself (X=H), nitroperbenzoates (X=para-, meta-, ortho-NO2), and methoxyperbenzoates (X=para-, meta-OCH3) were investigated in the gas phase by electrospray ionization tandem mass spectrometry. The collision-induced dissociation mass spectra of these compounds reveal product ions consistent with a major loss of carbon dioxide requiring unimolecular rearrangement of the perbenzoate anion prior to fragmentation. Isotopic labeling of the perbenzoate anion supports rearrangement via an initial nucleophilic aromatic substitution at the ortho carbon of the benzene ring, while data from substituted perbenzoates indicate that nucleophilic attack at the ipso carbon can be induced in the presence of electron-withdrawing moieties at the ortho and para positions. Electronic structure calculations carried out at the B3LYP/6311++G(d,p) level of theory reveal two competing reaction pathways for decarboxylation of perbenzoate anions via initial nucleophilic substitution at the ortho and ipso positions, respectively. Somewhat surprisingly, however, the computational data indicate that the reaction proceeds in both instances via epoxidation of the benzene ring with decarboxylation resulting-at least initially-in the formation of oxepin or benzene oxide anions rather than the energetically favored phenoxide anion. As such, this novel rearrangement of perbenzoate anions provides an intriguing new pathway for epoxidation of the usually inert benzene ring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple route for the preparation of lipo-alkaloid is presented. When aconitine or one of its analogues is heated with a fatty acid for 20 min at 100degreesC in water, the C-8 acetyl group of aconitine is displaced by along chain fatty acyl group. The structures of the products were characterized by electrospray ionization tandem mass spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cocaine is one of the most widespread illegal stimulants utilized by the human population throughout the world. The aim of this study was to establish the highest no-effect dose (HNED) of cocaine on the spontaneous locomotor activity (SLA) of horses in a behavior chamber, and thereby to determine the maximal acceptable threshold of the urinary drug concentration in horses. Twelve English thoroughbred mares received 0.02, 0.03, 0.04, 0.08 or 0.12 mg kg(-1) cocaine i.v. or saline solution (control). It was noted that doses above 0.04 mg kg(-1) induced a significant increase in SLA (P < 0.05, Tukey's test). No significant increase in SLA was seen in the mares that received 0.03 mg kg(-1), but the animals showed important behavioral changes that did not occur after the 0.02 mg kg(-1) dose. It was concluded that the HNED of cocaine for horses in a behavior chamber is 0.02 mg kg(-1). After injection of this dose in five horses, urine samples were collected at predetermined intervals through vesical catheterization. The concentrations of cocaine, norcocaine, benzoylecgonine and ecgonine methyl ester were quantified by liquid chromatography/electrospray ionization tandem mass spectrometry. Cocaine and norcocaine concentrations remained consistently below the level of detection. Benzoylecgonine reached a mean (+/- SEM) maximum concentration of 531.9 +/- 168.7 ng ml(-1) after 4 h, whereas ecgonine methyl ester peaked 2 h after injection at a concentration of 97.2 +/- 26.5 ng ml(-1). The maximum admissible concentration for cocaine and/or metabolites in the urine of horses is difficult to establish unequivocally because of the substantial individual variation in the drug elimination pattern observed in horses, which can be inferred by the large standard error of the means obtained. Copyright (C) 2002 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Contamination with bacteria and/or fungi is a serious complication in organ-cultured corneas. Hence, antibiotic and antifungal agents are added to the culture medium. The concentration of different antimicrobial and antifungal additives to the media over time has so far not been investigated in detail and is the aim of this study. METHODS Nine human fresh corneoscleral discs were stored in corneal culture medium consisting of 2% fetal bovine serum and minimal essential medium. In addition, the culture medium contained 1200 μg/mL penicillin G, 25 μg/mL amphotericin B, 120 μg/mL streptomycin, and 100 μg/mL voriconazole. The concentration of amphotericin B used was 10 times higher than in clinical routine to facilitate its detection. The cultures were kept at 37°C for 28 days. At days 0, 7, 14, 21, and 28, samples of the culture medium were harvested for analysis of antimicrobial concentrations by liquid chromatography and electrospray ionization tandem mass spectrometry. RESULTS During corneal storage, the concentration of all antibiotics and antifungal agents declined significantly. By day 28, penicillin G was reduced to 14% of the original concentration. Amphotericin B and streptomycin retained approximately 60% of the original concentration to the end of the experiment and voriconazole maintained stable concentrations after an initial decline to approximately 80% at 7 days. CONCLUSIONS Throughout the entire storage period, the concentrations of penicillin G, streptomycin, and voriconazole exceeded the minimum inhibitory concentrations of all common contaminants, obviating the need for a change of the medium for antimicrobial reasons. Based on the minimum inhibitory concentrations and our findings, the initial concentration of amphotericin B should be raised to 5 μg/mL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The aims of this study are to evaluate whether cytochrome P450 (CYP)2D1/2D2-deficient dark agouti (DA) rats and/or CYP2D1/2D2-replete Sprague-Dawley (SD) rats are suitable preclinical models of the human, with respect to mirroring the very low plasma concentrations of metabolically derived oxymorphone seen in humans following oxycodone administration, and to examine the effects of streptozotocin-induced diabetes on the pharmacokinetics of oxycodone and its metabolites, noroxycodone and oxymorphone, in both rodent strains. Methods. High-performance liquid chromatography-electrospray ionization-tandem mass spectrometry was used to quantify the serum concentrations of oxycodone, noroxycodone, and oxymorphone following subcutaneous administration of bolus doses of oxycodone (2 mg/kg) to groups of nondiabetic and diabetic rats. Results. The mean (+/- SEM) areas under the serum concentration vs. time curves for oxycodone and noroxycodone were significantly higher in DA relative to SD rats (diabetic, p < 0.05; nondiabetic, p < 0.005). Serum concentrations of oxymorphone were very low (< 6.9 nM). Conclusions. Both DA and SD rats are suitable rodent models to study oxycodone's pharmacology, as their systemic exposure to metabolically derived oxymorphone (potent mu-opioid agonist) is very low, mirroring that seen in humans following oxycodone administration. Systemic exposure to oxycodone and noroxycodone was consistently higher for DA than for SD rats showing that strain differences predominated over diabetes status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrospray ionization (ESI) combined with multiple-stage tandem mass spectrometry (MSn) was used to directly analyze the glycolipid mixture from bacteria Bacillus pumilus without preliminary separation. Full scan ESI-MS revealed the composition of picomole quantities of glycerolglycolipid species containing C-14-C-19 fatty acids, some of which were monounsaturated, Two main components were identified from their molecular masses and fragmentation pathways. The fragmentation pathway of the known compound compared with the investigated compound verified the proposed structure as 1(3)-acyl-2-pentadecanoyl-3(1)-O-[beta-D-glucopyranosyl-(1-->6)-O-beta-D-glucopyranosyl]-sn-glycerols. A comparison of the multiple tandem mass spectra of the different alkali-metal cation adducts indicates that the intensity of fragments and the dissociation pathways are dependent on the alkali-metal type, The basic structures of glycerolglycolipids were reflected clearly from the fragmentation patterns of the sodium cations, The intense fragments of the sugar residue from the precursor ions were obtained from the lithiated adduct ions. ESI-MSn spectra of [M + K](+) ions did not provide as much fragmentation as [M + Na](+) and [M + Li](+) adducts, but their spectra allow the position of glycerol acylation to be determined. On the basis of MS2 spectra of[M + K](+) ions, it was established that all components have a C-15:0 fatty acid at the sn-2 position of the glycerol backbone and C-14-C-19 acids at the sn-1 position of the glycerol backbone. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scoparone (6,7-dimethoxycoumarin) is known to have a wide range of pharmacological properties. In this study, a rapid and validated ultra-performance liquid chromatography/electrospray ionization quadruple time-of-flight mass spectrometry (UPLC/ESI-QTof-MS) method was developed to investigate the metabolism of scoparone in rat for the first time. The new method reduced the sample handling and analytical time by three- to six-fold, and the detection limit by five- to 1000-fold, compared to published methods. Far more metabolites were detected and identified compared to published data, which were preliminarily identified as scopoletin, isoscopoletin, isofraxidin, and fraxidin, respectively, when subjected to tandem mass spectrometry analyses. It is found that the metabolic trajectory of scoparone in rat focused on phase I metabolism which is obviously different from published results, and revealed a wide range of pharmacological properties of scoparone partly attributed to the bioactivities of its metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The non-covalent complexes between three flavonoid glycosides (quercitrin, hyperoside and rutin) and heptakis(2,6-di-O-methyl)-beta-cyclodextrin (DM-beta-CD) were investigated by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). The 1:1 complexation of each flavonoid glycoside (guest) to the DM-beta-CD (host) was monitored in the negative ion mode by mixing each guest with an up to 30-fold molar excess of the host. The binding constants for all complexes were calculated by a linear equation in the order: DM-beta-CD:quercitrin > DM-beta-CD:rutin > DM-beta-CD:hyperoside. A binding model for the complexes has also been proposed based on the binding constants and tandem mass spectrometric data of these complexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using electrospray ionization (ESI) and tandem mass spectrometry techniques, the protonic positions in protonated molecular ions of some narcotic drugs were studied, The data of ESI/MSn experiments of morphine and deuterium-loaded morphine were first discussed. The protonic position was considered to locate on oxygen atom of cyclic ether in morphine molecular, Compared with the same and different: ions among morphine, codeine, acetylcodeine and dihydrocodeine, the protonic positions in protonated molecular ions of these compounds were further determined. The fragmentation mechanism of morphine in ESI/MSn: experiments was also repored in the paper, and there were similar dehydrolysis mechanism in gas phase or in liquid phase for morphine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Positive and negative ion electrospray ionization (ESI) mass spectra of complexes of positively charged small molecules (distamycin, Hoechst 33258, [Ru(phen)2dpq]Cl2 and [Ru(phen)2dpqC]Cl2) have been compared. [Ru(phen)2dpq]Cl2 and [Ru(phen)2dpqC]Cl2 bind to DNA by intercalation. Negative ion ESI mass spectra of mixtures of [Ru(phen)2dpq]Cl2 or [Ru(phen)2dpqC]Cl2 with DNA showed ions from DNA-ligand complexes consistent with solution studies. In contrast, only ions from freeDNAwere present in positive ion ESI mass spectra of mixtures of [Ru(phen)2dpq]Cl2 or [Ru(phen)2dpqC]Cl2 with DNA, highlighting the need for obtaining ESI mass spectra of non-covalent complexes under a range of experimental conditions. Negative ion spectra of mixtures of the minor groove binder Hoechst 33258 with DNA containing a known minor groove binding sequence were dominated by ions from a 1:1 complex. In contrast, in positive ion spectra there were also ions present from a 2:1 (Hoechst 33258: DNA) complex, suggesting an alternative binding mode was possible either in solution or in the gas phase. When Hoechst 33258 was mixed with a DNA sequence lacking a high affinity minor groove binding site, the negative ion ESI mass spectra showed that 1:1 and 2:1 complexes were formed, consistent with existence of binding modes other than minor groove binding. The data presented suggest that comparison of positive and negative ion ESI-MS spectra might provide an insight into various binding modes in both solution and the gas phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pressurized capillary electrochromatography (pCEC) was coupled with electrospray ionization mass spectrometry (ESI-MS) using a coaxial sheath liquid interface. It was used for separation and analysis of peptides and proteins. The effects of organic modifier and applied voltage on separation were investigated, and the effects of pH value of the mobile phase and the concentration of the electrolyte on ESI-MS signal were investigated. The resolution and detection sensitivity with different separation methods (pCEC, capillary high-performance liquid chromatography) coupled on-line with mass spectrometry were compared for the separation of a peptide mixture. To evaluate the feasibility and reliability of the experimental setup of the system, tryptic digests of cytochrome c and modified protein as real samples were analyzed by using pCEC-ESI-MS.