975 resultados para Ductus arteriosus, patent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the case of a 48-year-old woman who underwent elective percutaneous patent foramen ovale closure following successive renal and myocardial infarction with normal renal and coronary arteries, probably as a consequence of paradoxical emboli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. METHODS: On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. RESULTS: CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. CONCLUSIONS: In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migraine is a recurrent disabling disorder predominantly affecting middle-aged women. Migraine occurs with or without aura symptoms. Several studies have shown an increased prevalence of right-to-left shunts (RLSs) in migraine with aura. The overwhelming majority of these shunts were due to a patent foramen ovale (PFO). Furthermore, migraine with aura is more prevalent in clinical entities associated with a RLS, e.g. cryptogenic stroke, decompression illness in divers, or in patients with hereditary hemorrhagic teleangiectasia and pulmonary arteriovenous fistulas. Retrospective studies have consistently shown that shunt closure was associated with a significant reduction in migraine frequency. Its beneficial effect seemed to exceed the efficacy of conventional migraine therapy. Several randomized clinical trials to prospectively assess the benefit of shunt closure in migraine patients have been initiated. The only one completed, the MIST trial (Migraine Intervention with STARFLEX Technology), showed a significant reduction of migraine with aura after device implantation, compared with controls. However, the benefit of PFO closure was more modest than expected. This review recapitulates the current data regarding PFO closure and migraine with aura and summarizes in brief the current knowledge regarding migraine pathophysiology and the link to a RLS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patent foramen ovale (PFO) is a common finding present in 25% of the population. A relationship between PFO and several clinical conditions such as stroke, migraine, platypnea-orthodeoxia syndrome, neurological decompression illness in divers, high altitude pulmonary edema, sleep apnea, and economy class syndrome have been documented. Observational non-randomized studies have shown percutaneous PFO closure more effective than medical treatment for stroke prevention, in particular in patients with complete closure as well as in patients with more than one cerebrovascular event at baseline. In the case of migraine, PFO closure has been shown to result in a marked reduction in migraine burden or migraine days. PFO anatomy, epidemiological data on associated clinical conditions, comparison between percutaneous closure and medical treatment, as well as the technical aspect of the procedure are described in this review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This randomized trial compared procedural complications and 30-day clinical outcomes of 3 patent foramen ovale (PFO) closure devices (Amplatzer, Helex, and CardioSEAL-STARflex). It examined 660 patients (361 men, 299 women, mean age 49.3+/-1.9 years), with 220 patients per group. All patients had a history of paradoxical embolism. All PFO closures were successful technically. Exchange of devices for others was most frequently required for the Helex occluder (7 of 220) and 2 of 220 in either of the other groups. Three device embolizations in the Helex group were retrieved and replaced successfully. One patient with a Helex occluder developed a transient ischemic attack and recovered without treatment. A hemopericardium in that group was punctured without affecting the device. One tamponade in the Amplatzer group required surgical device explantation. In 8 of 660 patients in the CardioSEAL-STARflex group, thrombi resolved after anticoagulation. Sixteen patients (11 in the CardioSEAL-STARflex group, 3 in the Amplatzer group, and 2 in the Helex group) had episodes of atrial fibrillation. PFOs were closed completely in 143 of 220 patients (65%) in the Amplatzer group, 116 of 220 patients (52.7%) in the Helex group, and 137 of 220 patients (62.3%) in the CardioSEAL-STARflex group at 30 days with significant differences between the Helex and Amplatzer occluders (p=0.0005) and the Helex and CardioSEAL-STARflex occluders (p=0.0003). PFO closure can be performed safely with each device. In conclusion, the Helex occluder embolized more frequently. Device thrombus formation and paroxysmal atrial fibrillation were more common with the CardioSEAL-STARflex occluder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Recurrent embolic events after device closure of patent foramen ovale (PFO) have been related to incomplete closure. Another cause could be atrial fibrillation (AF). The aim of this study was to determine the incidence of AF in stroke patients after PFO closure. METHODS: Consecutive patients with device closure of a PFO after a stroke or transient ischemic attack and control patients with stroke underwent 7-day event loop recordings 3 and 6 months after PFO closure or stroke, respectively. RESULTS: Forty patients treated by PFO device closure 96 +/- 68 days after cryptogenic ischemic stroke and 70 control patients with ischemic stroke of other etiologies (known AF excluded) were compared. AF was identified in 6 patients (15%) of the treated group and in 12 control patients (17%, p = 0.77). In multivariate analysis, the presence of an occluder device was not an independent risk factor for AF. CONCLUSIONS: The incidence of AF is high after device closure of a PFO in stroke patients and similar to that in patients with stroke of non-PFO etiology and, hence, with no device. Further studies are required to determine the risk of thromboembolism and the optimal treatment in patients developing AF after device closure of a PFO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of transseptal puncture for catheter ablation of atrial fibrillation after percutaneous closure of a foramen ovale with the Amplatzer Occluder is demonstrated based on 2 representative cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Patent foramen ovale (PFO) has been linked to migraine, and several retrospective studies reported an improvement in migraine prevalence or frequency after PFO closure for other reasons, mostly for secondary prevention of paradoxical embolism or following diving accidents. We investigated the outcome of patients undergoing PFO closure solely for migraine headaches refractory to medical treatment. METHODS: Seventeen patients (age 44 +/- 12 years; 76% female; one atrial septal aneurysm) underwent percutaneous PFO closure using the Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, MN). An 18-mm device was used in two patients, a 25-mm device in 13, and a 35-mm device in two. The interventions were solely guided by fluoroscopy, without intraprocedural echocardiography. RESULTS: All implantation procedures were successful. There were no peri-procedural complications. Contrast transesophageal echocardiography after Valsalva maneuver at 6 months showed complete PFO closure in 16 patients (94%), whereas a minimal residual shunt persisted in one (6%). During 2.7 +/- 1.5 years of follow-up, no deaths and no embolic events occurred. After PFO closure, migraine headaches disappeared in four patients (24%), and improved in eight additional patients (47%). Three patients (18%) reported a decrease of their headaches by 75%, three patients (18%) a decrease of 50%, and two patients (12%) a decrease of 25%, while headaches remained unchanged in five patients (29%). No patient experienced worsening headaches. Moreover, the prevalence of migraine with aura decreased from 82 to 24% (P = 0.002). CONCLUSIONS: These results suggest that percutaneous PFO closure durably alters the spontaneous course of shunt associated migraine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Sex differences in patients with patent foramen ovale (PFO) and cryptogenic stroke have not been systematically analyzed. We aimed to determine sex influences on demographics, vascular risk factors, clinical manifestations, stroke location, and clinical outcome. METHODS: One thousand two hundred eighty-eight consecutive patients with ischemic stroke or transient ischemic attack (TIA) were admitted to a single stroke center. All patients underwent a complete stroke workup including clinical examination, standard blood tests, cerebral and vascular imaging, transesophageal echocardiography, and 24-hour electrocardiography. In 500 patients, no definite etiology could be established (cryptogenic stroke/TIA). Of them, 167 patients (107 men and 60 women, mean age 52 +/- 13 years) had an PFO. RESULTS: The prevalence of PFO in patients with cryptogenic stroke or TIA was higher in men than in women (38% vs 28%, P = .014). Stroke severity and the prevalence of risk factors did not differ between the 2 sexes. There was an independent association between male sex and stroke location in the posterior cerebral circulation (OR 3.0, 95% CI 1.4-6.5, P = .006). Men and women did not differ in respect to PFO grade, prevalence of right-to-left shunt at rest, or coexistence of atrial septal aneurysm. Clinical outcome at 3 months was similar in both sexes. CONCLUSION: Patent foramen ovale was more prevalent in men than in women with cryptogenic stroke. There were no sex influences on age, risk factors, echocardiographic characteristics of PFO, or clinical outcome. Male sex was independently associated with stroke in the posterior cerebral circulation.