900 resultados para Detection system


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml(-1), with a detection limit of 3 ng ml(-1). The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n = 7) by measuring 0.5 mug ml(-1) antigen standard solution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

阀门泄漏的在线监测一直是困扰流程工业的难题,采用传统有线监控方式需要巨大的布线安装成本。本文通过结合无线通信技术和超声检测技术,研究并开发了一种基于无线通信的阀门泄漏检测系统,可极大地降低测控系统的投资和使用成本,通过实时检测阀门的工作状态,及时发现并定位泄漏位置,实现工业生产的节能降耗。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文阐明了数字式热轴自动判别及集中检测的原理,并从理论上对一些重点环节进行分析。该系统经过实践检验,证明性能良好,功能齐全,自动判别准确率高。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文根据汽车变速箱装配线螺栓检测的要求,结合检测现场的实际图像特点,采用融合灰度投影与颜色直方图两种特征的方法,利用相似性测度的计算方法,设计了一种变速箱螺栓在线装配质量检测系统,该系统用于实现螺栓的的缺失及漏拧检测,试验结果表明,方法具有良好的实用性,取得了比较理想的效果。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文依托于中科院沈阳自动化研究所自动化装备研究室的项目——PASSIM卷接机组改造。PASSIM卷接机组是从英国MOLINS公司引进的设备,限于当时的硬件设计技术、芯片封装技术和通信技术,导致系统控制体积大,系统内部之间的连接也很复杂,同时旧的检测标准也不符合现在的要求。在消化吸收了国外设计思想的基础上,开发出了新型的烟支质量检测控制系统。在新的检测控制系统中采用了TI公司的DSP处理器,TMS320F2812完成系统中的数据采样、A/D转换和数据处理等功能,由于DSP处理器的A/D 采样精度高,运算速度快,满足了系统在速度和精度上的要求;同时,系统选用CYGNAL公司的单片机8051F020与上位机进行RS-485数据通讯,DSP与单片机之间采用双口RAM来共享数据。系统很好的完成了数据采集处理和数据交换的功能,对烟支质量做到了检测准确,剔除实时,取得了良好的使用效果。 本文首先对卷烟机的构成和控制系统作了简单的分析和介绍,剖析了烟支质量检测的原理,包括重量、稀释度和空头信号的产生,采集和处理。接着详细阐述了系统的具体方案设计,结合卷烟机工艺要求,按检测信号的分布将系统分为三个检测子站,对子站的设计进行了详细的分析。设计分为硬件和软件部分,硬件部分包括芯片的选择和接口电路的实现,软件则主要用来实现对重量、稀释度和空头信号的处理分析,及时剔除不合格烟支。最后介绍了系统在现场对传感器的校准和参数调整过程,并对运行结果进行了分析,实践证明系统是高效可靠的,满足了检测和控制的要求。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple method, based on the technique of capillary column switching-back flushing, has been developed for the detailed analysis of aromatic compounds in gasoline. The sample was first separated on a 30-m long OV-2330 polar precolumn and then backflushed onto a nonpolar analytical column. The early eluting components from the precolumn and the components of interest (aromatic compounds plus heavier compounds) eluting from the analytical column are all directed to the same flame ionization detection system through a T piece, which permits the quantitative analysis of aromatic hydrocarbons in gasoline by a normalization method using correcting factors. The switching time window of the method is +/-5 s, resulting in easier operation and higher reliability. The reproducibility of the quantitative analysis was less than or equal to3% RSD for real gasoline samples. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acousto-optic imaging (AOI) in optically diffuse media is a hybrid imaging modality in which a focused ultrasound beam is used to locally phase modulate light inside of turbid media. The modulated optical field carries with it information about the optical properties in the region where the light and sound interact. The motivation for the development of AOI systems is to measure optical properties at large depths within biological tissue with high spatial resolution. A photorefractive crystal (PRC) based interferometry system is developed for the detection of phase modulated light in AOI applications. Two-wave mixing in the PRC creates a reference beam that is wavefront matched to the modulated optical field collected from the specimen. The phase modulation is converted to an intensity modulation at the optical detector when these two fields interfere. The interferometer has a high optical etendue, making it well suited for AOI where the scattered light levels are typically low. A theoretical model for the detection of acoustically induced phase modulation in turbid media using PRC based interferometry is detailed. An AOI system, using a single element focused ultrasound transducer to pump the AO interaction and the PRC based detection system, is fabricated and tested on tissue mimicking phantoms. It is found that the system has sufficient sensitivity to detect broadband AO signals generated using pulsed ultrasound, allowing for AOI at low time averaged ultrasound output levels. The spatial resolution of the AO imaging system is studied as a function of the ultrasound pulse parameters. A theoretical model of light propagation in turbid media is used to explore the dependence of the AO response on the experimental geometry, light collection aperture, and target optical properties. Finally, a multimodal imaging system combining pulsed AOI and conventional B- mode ultrasound imaging is developed. B-mode ultrasound and AO images of targets embedded in both highly diffuse phantoms and biological tissue ex vivo are obtained, and millimeter resolution is demonstrated in three dimensions. The AO images are intrinsically co-registered with the B-mode ultrasound images. The results suggest that AOI can be used to supplement conventional B-mode ultrasound imaging with optical information.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The advent of digital microfluidic lab-on-a-chip (LoC) technology offers a platform for developing diagnostic applications with the advantages of portability, reduction of the volumes of the sample and reagents, faster analysis times, increased automation, low power consumption, compatibility with mass manufacturing, and high throughput. Moreover, digital microfluidics is being applied in other areas such as airborne chemical detection, DNA sequencing by synthesis, and tissue engineering. In most diagnostic and chemical-detection applications, a key challenge is the preparation of the analyte for presentation to the on-chip detection system. Thus, in diagnostics, raw physiological samples must be introduced onto the chip and then further processed by lysing blood cells and extracting DNA. For massively parallel DNA sequencing, sample preparation can be performed off chip, but the synthesis steps must be performed in a sequential on-chip format by automated control of buffers and nucleotides to extend the read lengths of DNA fragments. In airborne particulate-sampling applications, the sample collection from an air stream must be integrated into the LoC analytical component, which requires a collection droplet to scan an exposed impacted surface after its introduction into a closed analytical section. Finally, in tissue-engineering applications, the challenge for LoC technology is to build high-resolution (less than 10 microns) 3D tissue constructs with embedded cells and growth factors by manipulating and maintaining live cells in the chip platform. This article discusses these applications and their implementation in digital-microfluidic LoC platforms. © 2007 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Proton imaging has become a common diagnostic technique for use in laser-plasma research experiments due to their ability to diagnose electric field effects and to resolve small density differences caused through shock effects. These interactions are highly dependent on the use of radiochromic film (RCF) as a detection system for the particle probe, and produces very high-resolution images. However, saturation effects, and in many cases, damage to the film limits the usefulness of this technique for high-flux particle probing. This paper outlines the use of a new technique using contact radiography of (p,n)-generated isotopes in activation samples to produce high dynamic range 2D images with high spatial resolution and extremely high dynamic range, whilst maintaining both energy resolution and absolute flux measurements. (C)007 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Gray Laboratory charged-particle microbeam has been used to assess the clonogenic ability of Chinese hamster V79 cells after irradiation of their nuclei with a precisely defined number of protons with energies of 1.0 and 3.2 MeV. The microbeam uses a 1-mum. silica capillary collimator to deliver protons to subcellular targets with high accuracy. The detection system is based on a miniature photomultiplier tube positioned above the cell dish, which detects the photons generated by the passage of the charged particles through an 18-mum-thick scintillator placed below the cells. With this system, a detection efficiency of greater than 99% is achieved. The cells are plated on specially designed dishes (3-mum-thick Mylar base), and the nuclei are identified by fluorescence microscopy. After an incubation period of 3 days, the cells are revisited individually to assess the formation of colonies from the surviving cells. For each energy investigated, the survival curve obtained for the microbeam shows a significant deviation below I Gy from a response extrapolated using the LQ model for the survival data above 1 Gy. The data are well fitted by a model that supports the hypothesis that radioresistance is induced by low-dose hypersensitivity. These studies demonstrate the potential of the microbeam for performing studies of the effects of single charged particles on cells in vitro. The hypersensitive responses observed are comparable with those reported by others using different radiations and techniques. (C) 2001 by Radiation Research Society.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study we report on the synthesis, kinetic characterization and application of a novel biotinylated and active-site-directed inactivator of cathepsin B. Thus the peptidyliazomethane biotinyl-Phe-Ala-diazomethane has been synthesized by a combination of solid-phase and solution methodologies and has been shown to be a very efficient inactivator of bovine and human cathepsin B. The respective apparent second-order rate constants (k0bs./[I]) for the inactivation of the human and bovine enzymes by this reagent, namely approximately 5.4 x 10(4) M-1 and approximately 7.8 x 10(4) M-1, compare very favourably with those values determined for the urethane-protected analogue benzloxycarbonyl-Phe-Ala-chloromethane first described by Green & Shaw [(1981) J.Biol. Chem. 256, 1923-1928], thus demonstrating that the presence of the biotin moiety at the P3 position is compatible with inhibitor effectiveness. The utilization of this reagent for the detection of cathepsin B in electrophoretic gels, using Western blotting and in combination with a streptavidin/alkaline phosphatase detection system, is also demonstrated. Given that the peptidydiazomethanes exhibit a pronounced reactivity towards cysteine proteinases, we feel that the present label may well constitute the archetypal example of a wide range of reagents for the selective labelling of this class of proteinase, even in a complex biological milieu containing additional classes of proteinases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An optimised indirect peroxidase-anti-peroxidase immunohistochemical technique was used to detect endogenous biotin in frozen tissue sections from biotin-supplemented and biotin-depleted pigs and chickens. A monoclonal anti-biotin antibody was used as primary antibody in this technique. Immunoreactive biotin was detected in many tissues of both species including liver, kidney, pancreas, adipose tissue, adrenal gland, testis, brain, choroid plexus, cardiac and skeletal muscle, epithelium of the respiratory and digestive systems, skin and lymphoid tissues. The specificity of immunostaining for biotin was confirmed by the finding of reduced staining intensities in tissues of biotin-depleted animals compared to those of biotin-supplemented animals. The results of this study suggest that biotin has metabolic functions in a wider range of tissues than previously known. They also indicate that endogenous tissue biotin should be considered as a source of false positive staining when immunohistochemical or histochemical techniques which use avidin or streptavidin reagents or anti-biotin antibodies as components of the detection system, are applied to tissue sections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A proof-of-concept study was reported on analysis of antigen–antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles in an imaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, individual Au nanoparticles (30 nm) were observed with high signal-to-noise ratio and they were effectively utilized to monitor changes in refractive index induced by specific binding of the adsorbates. Using PSA antigen as a model, a LSPR ?max shift of about 2.85 nm was recorded for a molecular binding corresponding to 0.1 pg ml-1 of the protein biomarker. This result successfully demonstrates a non-labeling detection system for proteins as well as thousands of different chemical or biological species, and it possesses a great potential as a sensitive, on-chip and multiplexing detection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare caries incidence following two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the Shortened Dental Arch (SDA) and conventional treatment using Removable Partial Dentures (RPDs). Method:A randomised controlled clinical trial (RCT) was conducted of partially dentate patients aged 65 years and older. Patients were randomly allocated to two different treatment groups: the RPD group and the SDA group. Each member of the RPD group was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. Patients in the SDA group were restored to a shortened arch of 10 occluding pairs of natural and replacement teeth using adhesive bridgework. All of the operative treatment was completed by a single operator. Caries incidence was measured over a 2-year period following treatment intervention and recorded using the International Caries and Detection System (ICDAS). Result:In total, 89 patients completed the RCT (45 SDAs and 44 RPDs). Patients in the RPD group recorded a significantly higher incidence of new carious lesions (p<0.001) and recurrent carious lesions (p<0.001) compared to the SDA group. A mixed model of covariance (ANCOVA) revealed that treatment group (p<0.001) and co-morbidity (p<0.001) were significant predictors of caries incidence. Conclusion:Two years after provision of prosthodontic treatment there was a significantly higher incidence of new and recurrent caries lesions in subjects provided with RPDs compared with SDA treatment. This will have a significant impact on the ongoing maintenance costs for these two treatment groups.