953 resultados para Dental prostheses and dental implants
Resumo:
Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.
Resumo:
The present article discusses an atrophic maxilla reconstruction with iliac crest bone block and particulate grafts and dental implants. Onlay block grafts were used to restore bone volume of the anterior maxilla, whereas bilateral sinus floor augmentation was performed using a particulate graft. Ten months after the grafting surgery, 9 dental implants were placed to rehabilitate the case. Results of a 7-year follow-up were obtained clinically and by cone beam computed tomographic images.
Resumo:
A myriad of titanium (Ti) surface modifications has been proposed to hasten the osseointegration. In this context, the aim of this study was to perform histomorphometric, cellular, and molecular analyses of the bone tissue grown in close contact with Ti implants treated by anodic spark deposition (ASD-AK). Acid-etched (AE) Ti implants either untreated or submitted to ASD-AK were placed into dog mandibles and retrieved at 3 and 8 weeks. It was noticed that both implants, AE and ASD-AK, were osseointegrated at 3 and 8 weeks. Histomorphometric analysis showed differences between treatments only for bone-to-implant contact, being higher on AE implants. Although not backed by histomorphometric results, gene expression of key bone markers was higher for bone grown in close contact with ASD-AK and for cells harvested from these fragments and cultured until subconfluence. Cell proliferation at days 7 and 10 and alkaline phosphatase activity at day 10 was higher on AE surfaces. No statistical significant difference was noticed for extracellular matrix mineralization at 17 days. Our results have shown that the Ti fixtures treated by ASD-AK allowed in vivo osseointegration and induced higher expression of key markers of osteoblast phenotype, suggesting that this surface treatment could be considered to produce implants for clinical applications. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 100A:30923098, 2012.
Resumo:
Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncmusing a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.
Resumo:
Treatment of patients with cleft lip and palate is completed with fixed prostheses, removable, total, implants and aims to restore aesthetics, phonetics and function and should be guided by the basic principles of oral rehabilitation, such as physiology, stability, aesthetics, hygiene and the expectations of the patient. In order to obtain longevity of a prosthetic rehabilitation, the periodontal and dental tissue as well as the biomechanics of the prosthesis are to be respected. The purpose of this article is to describe the types of prosthetics treatment, which are performed at HRAC/USP for the rehabilitation of cleft area in adult patients.
Resumo:
BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.
Resumo:
PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.
Resumo:
Background: After oral tumor resection, structural and functional rehabilitation by means of dental prostheses is complex, and positive treatment outcome is not always predictable. Purpose: The objective of the study was to report on oral rehabilitation and quality of life 2-5 years after resection of malignant oral tumors. Materials and Methods: Data of 46 patients (57 ± 7 years) who underwent oral tumor surgery were available. More than 50% of tumors were classified T3 or T4. Open oro-nasal defects resulted in 12 patients and full mandibulary block resections in 23 patients. Comprehensive planning, implant placement, and prosthetic rehabilitation followed an interdisciplinary protocol. Analysis comprised tumor location, type of prostheses, implant survival, and quality of life. Results: Because of advanced tumor status, resections resulted in marked alteration of the oral anatomy requiring complex treatment procedures. Prosthetic rehabilitation comprised fixed and removable prostheses, with 104 implants placed in 28 patients (60%). Early implant loss was high (13%) and cumulative survival rate of loaded implants was <90% after 5 years. Prosthetic plans had to be modified because of side effects of tumor therapy, complications with implants and tumor recurrence. The majority of patients rated quality of life favorable, but some experienced impaired swallowing, dry mouth, limited mouth opening, appearance, and soreness. Conclusions: Some local effects of tumor therapy could not be significantly improved by prosthetic rehabilitation leading to functional and emotional disability. Many patients had passed away or felt too ill to fill the questionnaires. This case series confirms the complex anatomic alterations after tumor resection and the need for individual treatment approaches especially regarding prosthesis design. In spite of disease-related local and general restrictions, most patients gave a positive assessment of quality of life.
Resumo:
For dental implants to be successful, osseointegration must occur, but it is unknown how much time must pass for osseointegration to be established. Preclinical studies suggested that titanium implants with a sandblasted and acid-etched (SLA) surface were more osteoconductive and allowed more rapid osseointegration than machined or turned implant surfaces. The hypothesis of this study was that implants with an SLA surface could be loaded in half the conventional healing time of machined-surface implants and that, after loading, the implants would be successful for 5 years.
Resumo:
The term osseoperception describes the capability of developing a subtle tactile sensibility over dental implants. The present clinical study aims at clarifying the question of how far tactile sensibility is to be attributed to the periodontium of the natural opposing tooth of the implant.
Resumo:
BACKGROUND: Bone morphogenetic protein (BMP) is a potent differentiating agent for cells of the osteoblastic lineage. It has been used in the oral cavity under a variety of indications and with different carriers. However, the optimal carrier for each indication is not known. This study examined a synthetic bioabsorbable carrier for BMP used in osseous defects around dental implants in the canine mandible. METHODS: Twelve canines had their mandibular four premolars and first molar teeth extracted bilaterally. After 5 months, four implants were placed with standardized circumferential defects around the coronal 4 mm of each implant. One-half of the defects received a polylactide/glycolide (PLGA) polymer carrier with or without recombinant human BMP-2 (rhBMP-2), and the other half received a collagen carrier with or without rhBMP-2. Additionally, one-half of the implants were covered with a non-resorbable (expanded polytetrafluoroethylene [ePTFE]) membrane to exclude soft tissues. Animals were sacrificed either 4 or 12 weeks later. Histomorphometric analysis included the percentage of new bone contact with the implant, the area of new bone, and the percentage of defect fill. This article describes results with the PLGA carrier. RESULTS: All implants demonstrated clinical and radiographic success with the amount of new bone formed dependent on the time and presence/absence of rhBMP-2 and presence/absence of a membrane. The percentage of bone-to-implant contact was greater with rhBMP-2, and after 12 weeks of healing, there was approximately one-third of the implant contacting bone in the defect site. After 4 weeks, the presence of a membrane appeared to slow new bone area formation. The percentage of fill in membrane-treated sites with rhBMP-2 rose from 24% fill to 42% after 4 and 12 weeks, respectively. Without rhBMP-2, the percentage of fill was 14% rising to 36% fill, respectively. CONCLUSIONS: After 4 weeks, the rhBMP-2-treated sites had a significantly higher percentage of contact, more new bone area, and higher percentage of defect fill than the sites without rhBMP-2. After 12 weeks, there was no significant difference in sites with or without rhBMP-2 regarding percentage of contact, new bone area, or percentage of defect fill. In regard to these three outcomes, comparing the results with this carrier to the results reported earlier with a collagen carrier in this study, only the area of new bone was significantly different with the collagen carrier resulting in greater bone than the PLGA carrier. Thus, the PLGA carrier for rhBMP-2 significantly stimulated bone formation around dental implants in this model after 1 month but not after 3 months of healing. The use of this growth factor and carrier combination appears to stimulate early bone healing events around the implants but not quite to the same degree as a collagen carrier.
Resumo:
AIM: The purpose of this randomized split-mouth clinical trial was to determine the active tactile sensibility between single-tooth implants and opposing natural teeth and to compare it with the tactile sensibility of pairs of natural teeth on the contralateral side in the same mouth (intraindividual comparison). MATERIAL AND METHODS: The hypothesis was that the active tactile sensibilities of the implant side and control side are equivalent. Sixty two subjects (n=36 from Bonn, n=26 from Bern) with single-tooth implants (22 anterior and 40 posterior dental implants) were asked to bite on narrow copper foil strips varying in thickness (5-200 microm) and to decide whether or not they were able to identify a foreign body between their teeth. Active tactile sensibility was defined as the 50% threshold of correct answers estimated by means of the Weibull distribution. RESULTS: The results obtained for the interocclusal perception sensibility differed between subjects far more than they differed between natural teeth and implants in the same individual [implant/natural tooth: 16.7+/-11.3 microm (0.6-53.1 microm); natural tooth/natural tooth: 14.3+/-10.6 microm (0.5-68.2 microm)]. The intraindividual differences only amounted to a mean value of 2.4+/-9.4 microm (-15.1 to 27.5 microm). The result of our statistical calculations showed that the active tactile sensibility of single-tooth implants, both in the anterior and posterior region of the mouth, in combination with a natural opposing tooth is similar to that of pairs of opposing natural teeth (double t-test, equivalence margin: +/-8 microm, P<0.001, power >80%). Hence, the implants could be integrated in the stomatognathic control circuit.
Resumo:
PURPOSE: The aim of this study was to evaluate the 3-year success rates of wide-body implants with a regular- or wide-neck configuration and a sandblasted, large grit, acid-etched (SLA) surface. MATERIALS AND METHODS: A total of 151 implants were consecutively placed in posterior sites of 116 partially edentulous patients in a referral clinic at the School of Dental Medicine, University of Bern. All implants were restored with cemented crowns or fixed partial dentures after a healing period of 6 to 8 weeks (for implants placed without simultaneous bone augmentation) or 10 to 14 weeks (for implants with simultaneous bone augmentation). All patients were recalled 36 months following implant placement for a clinical and radiographic examination. RESULTS: One implant failed to integrate during healing, and 11 implants were lost to follow-up and considered dropouts. The remaining 139 implants showed favorable clinical and radiographic findings and were considered successfully integrated at the 3-year examination. This resulted in a 3-year success rate of 99.3%. Radiographic evaluation of 134 implants indicated stability of the crestal bone levels: During the study period, the crestal bone level changed less than 0.5 mm for 129 implants. CONCLUSION: Successful tissue integration was achieved with wide-body implants with a regular or a wide-neck configuration and an SLA surface with high predictability. This successful tissue integration was well maintained for up to 3 years of follow-up.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the survival rate of grafts and implants placed with sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify studies on sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. RESULTS: The search provided 839 titles. Full-text analysis was performed for 175 articles resulting in 48 studies that met the inclusion criteria, reporting on 12,020 implants. Meta-analysis indicated an estimated annual failure rate of 3.48% [95% confidence interval (CI): 2.48%-4.88%] translating into a 3-year implant survival of 90.1% (95% CI: 86.4%-92.8%). However, when failure rates was analyzed on the subject level, the estimated annual failure was 6.04% (95% CI: 3.87%-9.43%) translating into 16.6% (95% CI: 10.9%-24.6%) of the subjects experiencing implant loss over 3 years. CONCLUSION: The insertion of dental implants in combination with maxillary sinus floor elevation is a predictable treatment method showing high implant survival rates and low incidences of surgical complications. The best results (98.3% implant survival after 3 years) were obtained using rough surface implants with membrane coverage of the lateral window.
Resumo:
Grafting of the maxillary sinus in both one- and two-stage protocols has become a highly predictable surgical technique for site development and for the placement of implants to support dentures. However, despite the predictability and high success rates reported for dental implants placed either simultaneously with or after a sinus floor elevation (SFE) procedure, complications have been reported. The aim of the following case report is to present an uncommon complication in a staged SFE procedure: the displacement of a dental implant into the maxillary sinus during insertion. As implant dentistry is becoming more and more popular among practitioners, and ever more demanding procedures for initial site development in jaws with bony deficiencies are being introduced into daily practice, the displacement of dental implants into the maxillary sinus during implant placement may become a more frequent complication. Management of this complication is presented, discussed, and evaluated in light of the current literature.