667 resultados para Debond Dent
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To identify the trend of authorship in dental implant by exploring the prevalence of coauthored articles and to investigate the collaboration efforts, trends in funding involved in original articles, and their relationships. Materials: Articles published in the Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each included articles, number of authors, collaboration efforts, and extramural funding were recorded. Descriptive and analytical statistics (alpha = 0.05), including logistic regression analysis and chi(2) test, were used. Results: From a total of 2085 articles, 1503 met the inclusion criteria. Publications with 5 or more authors increased over time (P = 0.813). The amount of collaboration among different disciplines, institutions, and countries all increased. The greatest increase of collaboration was seen among institutions (P = 0.09). Non-funding studies decreased over time (P = 0.031). There was a strong association between collaboration and funding for the manuscripts during the years studied (OR, 1.5). Conclusion: The number of authors per articles and collaborative studies increased over time in implant-related journals. Collaborative studies were more likely to be funded. (Implant Dent 2011;20:68-75)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The toothbrush is an effective instrument for oral diseases prevention. The flexibility and status of bristles, as well as the size of the handle are fundamental for an effective toothbrushing. Thus, the assessment of physical characteristics of toothbrushes is important. This study evaluated the deterioration and wear of bristles of toothbrushes used by preschool children. For the sample selection, five elementary schools were assorted from a city of the São Paulo State northwest region, one from each city area. All toothbrushes used by preschool children who aged between 5 and 6 years old and who attended the assorted schools were visually analysed by two calibrated examiners, according to the criteria proposed by Rawls HR, Mkwayi-Tulloch NJ, Casella R, Cosgrove R (J Dent Res 1989; 12: 1781): 0 - it is impossible to state if the toothbrush was used or not; 1 - the bristles seem to be separated within some tufts; 2 - most tufts are separated, many cover other tufts and present a large number of curved and inclined bristles; 3 - most tufts are covered by others and bristles are folded and tipped. In total, 333 toothbrushes were evaluated. The data obtained revealed that 57.96% of the toothbrushes presented adequate condition for utilization (scores 0 and 1), whereas 42.04% presented inadequate bristles for their function (scores 2 and 3). It was concluded that a great number of toothbrushes presented deterioration of the bristles. Thus, there is the need to guide and promote awareness among teachers, parents and children as well as the need to replace toothbrushes.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Intrusion of permanent teeth is one of the most severe types of traumatic injuries. Different treatment strategies have been proposed, and the best approach for each case depends on the stage of root development, severity of the intrusive luxation, presence of alveolar fracture and number of intruded teeth. The purpose of this paper is to describe the treatment management of 2 cases of severely intruded immature permanent maxillary central incisors in 71/2- and 8-year-old children. In case 1, the traumatized tooth was treated by surgical repositioning, while in case 2 watchful waiting for spontaneous re-eruption was the treatment of choice. Treatment strategies were successful in both cases, as demonstrated by the continuation of root development, maintenance of pulp vitality, and absence of signs of per/apical pathosis during the follow-up period. Regardless of the treatment strategy, traumatically intruded teeth should undergo periodical clinical and radiographic surveillance on a long-term basis to allow early detection of possible complications. (Pediotr Dent 2009;31:340-5) Received March 11, 2008 vertical bar Last Revision June 25, 2008 vertical bar Revision Accepted July 16, 2008
Resumo:
Moebius syndrome is a congenital, nonprogressive disorder clinically characterized by loss of facial expression, impaired stomatognathic system functions, incapacity to close the eyelids, and several oral impairments. The purpose of this paper was to present the clinical manifestations and the dental treatment in a 5-year, 2-month-old male Moebius syndrome patient. The child presented with facial asymmetry, difficulty performing facial mimic movements and pronouncing some letters, and compromised suction, mastication, breathing, and deglutition. An intraoral examination revealed hypofunction of the perioral muscles, cheeks and tongue, ankyloglossia, anterior open bite, and absence of carious lesions and dental anomalies. The dental treatment consisted of frenectomy and further placement of a removable orthodontic appliance with a palatal crib for correction of the anterior open bite. After 12 months of follow-up, anterior open bite decreased and speech, deglutition, and mastication improved. (Pediatr Dent 2009;31:289-93) Received March 8, 2008 vertical bar Lost Revision July 22, 2008 vertical bar Revision Accepted July 28, 2008
Resumo:
Purpose: This study's purpose was to assess the amount of dental enamel loss on primary incisors after manual or mechanical microabrasion with a phosphoric acid/pumice poste. Methods: Ten exfoliated primary maxillary incisors were bisected faciolingually and the resulting 20 halves were randomly assigned to 2 groups: group 1 (N=10) manual technique (plastic spatula); and group 2 (N=10) mechanical technique (rubber cup attached to a low-speed handpiece). Microabrasion was performed on the buccal surface using an abrasive paste prepared with 37% phosphoric acid and pumice. Ten 20-second applications alternated with 20-second risings were performed in each group. Enamel thickness measurements made under stereomi-croscopy before and after microabrasion were analyzed statistically by analysis of variance and pairwise t test. Results: There was a statistically significant difference (P=.003) between the manual and mechanical techniques. The mechanical technique produced a mean enamel loss of 274.16 mu m (66% of total enamel thickness), while the mean enamel loss with the manual technique was 152.59 mu m (39% of total enamel thickness). Conclusion: Manual microabrasion using a plastic spatula removed less enamel, but was sufficient to eliminate most superficial stains and defects, and may be a viable option for the microabrasive technique on primary teeth. (Pediatr Dent 2008;30:420-3) Received March 15, 2007 / Lost Revision September 19, 2007 / Revision Accepted October 19, 2007
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)