932 resultados para CsI(Tl)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent laboratory studies have suggested that heart rate variability (HRV) may be an appropriate criterion for training load (TL) quantification. The aim of this study was to validate a novel HRV index that may be used to assess TL in field conditions. Eleven well-trained long-distance male runners performed four exercises of different duration and intensity. TL was evaluated using Foster and Banister methods. In addition, HRV measurements were performed 5 minutes before exercise and 5 and 30 minutes after exercise. We calculated HRV index (TLHRV) based on the ratio between HRV decrease during exercise and HRV increase during recovery. HRV decrease during exercise was strongly correlated with exercise intensity (R = -0.70; p < 0.01) but not with exercise duration or training volume. TLHRV index was correlated with Foster (R = 0.61; p = 0.01) and Banister (R = 0.57; p = 0.01) methods. This study confirms that HRV changes during exercise and recovery phase are affected by both intensity and physiological impact of the exercise. Since the TLHRV formula takes into account the disturbance and the return to homeostatic balance induced by exercise, this new method provides an objective and rational TL index. However, some simplification of the protocol measurement could be envisaged for field use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the goals of psychological assessment focuses on the adaptation of its instruments to different populations. The objective of this study is to establish the psychometric properties and dimensional structure of the Spanish version of the Coping Responses Inventory- Adult Form (CRI-Adult, Moos, 1993). The following criteria were analyzed: a) descriptive statistics; b) internal consistency reliability (Cronbach"s alpha, and intercorrelations between scales); c) test-retest reliability (4-week interval); d) dimensionality of CRI-Adult (exploratory factor analysis); e) construct validity (confirmatory factor analysis); f) convergent criterion validity (correlations between CRI-Adult and Coping Strategies Indicator, CSI, Amirkhan, 1990), and g) predictive criterion validity (correlations between CRI-Adult, and SCL-90-R, Derogatis, 1983). The results, obtained with 800 adults from Barcelona and surrounding area (334 men and 466 women, aged between 18 to 76 years) indicate that the Spanish version of CRIAdult has satisfactory psychometric properties that allow using this test with guarantee.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de esta nota es aclarar en lo posible el intrincado panorama nomenclatural del género que nos ocupa. Trataremos en especial acerca de algunos binómenes establecidos por autores como Smith, Lapeyrouse y Timbal-Lagrave, a causa de los problemas que plantea el uso diverso que de ellos se ha hecho. Se imponía fijar la aplicación de tales nombres, designando, en los casos en que fuera posible, sus tipos nomenclaturales. Para ello hemos consultado los materiales originales, depositados en los herbarios: LINN The Linnean Society of London , P Muséum National d'Histoire Naturelle, Laboratoire de Phanérogamie, París y TL Laboratoire de Botanique, Université Paul Sabatier, Toulouse-: . Hacemos, también, algunas precisiones acerca de la nomenclatura de algunos híbridos existentes en la Península Ibérica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent mineralogical studies on archaeological pottery samples report significant variations in alkali metal concentrations due to environmental alterations during burial. Here we examine the effects of potassium (K) leaching on luminescence dating. The effect on the estimation of the dose rate is studied by considering four models of leaching (exponential, linear, early and late) and their impact on fine- and coarse-grain dating are calculated. The modeling approaches are applied to two cases of pottery in which evidence for alteration was found. Additionally, TL dating performed on pottery of one of the studied cases, indicates the importance of leaching effects on absolute dating measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Realizar levantamento sobre quais testes de controle de qualidade são realizados nos calibradores de dose dos serviços de medicina nuclear da cidade de São Paulo, SP. Estudar a exatidão das medições de atividade de sete calibradores de dose no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares, usando fontes de radionuclídeos importantes clinicamente. MATERIAIS E MÉTODOS: O levantamento sobre o controle de qualidade foi realizado a partir de questionários enviados aos serviços. Foram utilizados, no estudo de exatidão dos sete calibradores de dose, fontes de Ga-67, Tc-99m e Tl-201 e um instrumento padrão secundário. RESULTADOS: Os resultados do levantamento sobre os testes de controle de qualidade mostraram algumas impropriedades, por exemplo, a falta da realização diária do teste de reprodutibilidade por todos os serviços. Os resultados do teste de exatidão para os sete calibradores de dose estudados mostraram-se dentro do limite de aceitação da norma nacional (±10%). CONCLUSÃO: A situação com relação ao controle de qualidade de calibradores de dose é insatisfatória, de acordo com o pequeno número de serviços que participaram do levantamento. O estudo da exatidão em sete calibradores de dose não indicou falhas de desempenho e estabeleceu uma calibração desses instrumentos para as fontes utilizadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detailed in-vivo characterization of subcortical brain structures is essential not only to understand the basic organizational principles of the healthy brain but also for the study of the involvement of the basal ganglia in brain disorders. The particular tissue properties of basal ganglia - most importantly their high iron content, strongly affect the contrast of magnetic resonance imaging (MRI) images, hampering the accurate automated assessment of these regions. This technical challenge explains the substantial controversy in the literature about the magnitude, directionality and neurobiological interpretation of basal ganglia structural changes estimated from MRI and computational anatomy techniques. My scientific project addresses the pertinent need for accurate automated delineation of basal ganglia using two complementary strategies: ? Empirical testing of the utility of novel imaging protocols to provide superior contrast in the basal ganglia and to quantify brain tissue properties; ? Improvement of the algorithms for the reliable automated detection of basal ganglia and thalamus Previous research demonstrated that MRI protocols based on magnetization transfer (MT) saturation maps provide optimal grey-white matter contrast in subcortical structures compared with the widely used Tl-weighted (Tlw) images (Helms et al., 2009). Under the assumption of a direct impact of brain tissue properties on MR contrast my first study addressed the question of the mechanisms underlying the regional specificities effect of the basal ganglia. I used established whole-brain voxel-based methods to test for grey matter volume differences between MT and Tlw imaging protocols with an emphasis on subcortical structures. I applied a regression model to explain the observed grey matter differences from the regionally specific impact of brain tissue properties on the MR contrast. The results of my first project prompted further methodological developments to create adequate priors for the basal ganglia and thalamus allowing optimal automated delineation of these structures in a probabilistic tissue classification framework. I established a standardized workflow for manual labelling of the basal ganglia, thalamus and cerebellar dentate to create new tissue probability maps from quantitative MR maps featuring optimal grey-white matter contrast in subcortical areas. The validation step of the new tissue priors included a comparison of the classification performance with the existing probability maps. In my third project I continued investigating the factors impacting automated brain tissue classification that result in interpretational shortcomings when using Tlw MRI data in the framework of computational anatomy. While the intensity in Tlw images is predominantly

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treatment failure and symptomatic relapse are major concerns in American tegumentary leishmaniasis (TL). Such complications are seen frequently in Leishmania guyanensis infections, in which patients respond variously to first-line antileishmanials and are more prone to develop chronic cutaneous leishmaniasis. The factors underlying this pathology, however, are unknown. Recently, we reported that a double-stranded RNA virus, Leishmania RNA virus 1 (LRV1), nested within L. guyanensis parasites is able to exacerbate experimental murine leishmaniasis by inducing a hyperinflammatory response. This report investigates the prevalence of LRV1 in human L. guyanensis infection and its effect on treatment efficacy, as well as its correlation to symptomatic relapses after the completion of first-line treatment. In our cohort of 75 patients with a diagnosis of primary localized American TL, the prevalence of LRV1-positive L. guyanensis infection was elevated to 58%. All patients infected with LRV1-negative L. guyanensis were cured after 1 dose (22 of 31 [71%]) or 2 doses (31 of 31 [100%]) of pentamidine. In contrast, 12 of 44 LRV1-positive patients (27%) presented with persistent infection and symptomatic relapse that required extended therapy and the use of second-line drugs. Finally, LRV1 presence was associated with a significant increase in levels of intra-lesional inflammatory markers. In conclusion, LRV1 status in L. guyanensis infection is significantly predictive (P = .0009) of first-line treatment failure and symptomatic relapse and has the potential to guide therapeutic choices in American TL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Avaliar um protocolo de espectroscopia por ressonância magnética (ERM) do próton de hidrogênio (1H) bidimensional (2D) disponível comercialmente (Siemens Medical Systems; Erlangen, Alemanha), aplicado para nódulos adrenais e diferenciação das massas (adenomas, feocromocitomas, carcinomas e metástases). Materiais e Métodos: Um total de 118 pacientes (36 homens e 82 mulheres), apresentando-se com 138 nódulos/massas adrenais, foi avaliado prospectivamente (média de idade: 57,3 ± 13,3 anos). Uma sequência de ERM-1H-PRESS-CSI (espectroscopia por resolução de ponto-imagem por desvio químico) multivoxel foi utilizada. Análise espectroscópica foi realizada da esquerda-direita, sentido crânio-caudal, usando três sequências sagitais, além de sequências axiais e coronais T2-HASTE. Os seguintes índices foram calculados: colina (Cho)/creatina (Cr), 4,0–4,3 ppm/Cr, lipídio (Lip)/Cr, Cho/Lip e lactato (Lac)/Cr. Resultados: ERM-1H-2D foi bem sucedida em 123 (89,13%) lesões. Os valores de sensibilidade e especificidade encontrados para as proporções e pontos de corte avaliados foram: Cho/Cr ≥ 1,2, sensibilidade de 100% e especificidade de 98,2% (diferenciação de adenomas e carcinomas de feocromocitomas e metástases); 4,0–4,3 ppm/Cr ≥ 1,5, 92,3% de sensibilidade, especificidade de 96,9% (diferenciação de carcinomas e feocromocitomas de adenomas e metástases); Lac/Cr ≤ –7,449, sensibilidade de 90,9% e especificidade de 77,8% (diferenciação de feocromocitomas contra carcinomas e adenomas). Conclusão: Os dados da ERM-1H-2D foram eficazes e permitiram a diferenciação entre massas adrenais e nódulos na maioria das lesões com diâmetro > 1,0 cm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Amb l’objectiu de conèixer les relacions existents entre la força, el rendiment esportiu i la lesionabilitat en un equip masculí de bàsquet professional, es realitza un estudi prospectiu, observacional i descriptiu d’anàlisis d’estadístiques (71 partits), test de mig esquat (n = 7) i patologia lesional, monitoritzant la temporada 09/10, on es relacionen les dades obtingudes de cada jugador referents al rendiment esportiu per partit (valoració estadística), les mitjanes de força, velocitat i potència de cada mesocicle i la lesionabilitat. La tècnica estadística utilitzada ha estat la correlació a partir del paràmetre rho de Spearman. Aquestes correlacions entre força i lesionabilitat mostren que a valors de força més elevats hi ha més lesions: amb 80 kg són molt significatives per a lesions totals (LT) i potència (rho = 0,898; p = 0,006), i significatives per força (rho = 0,823; p = 0,023) i velocitat (rho = 0,774; p = 0,041); la velocitat amb 90 kg es relaciona amb lesions time loss (TL) (rho = 0,878; p = 0,009), i la potència amb 100 kg, amb lesions totals (LT) (rho = 0,805; p = 0,029) i V100 (rho = 0,898; p = 0,006) molt significativament. I la relació entre força i rendiment és significativament negativa en 5 dels 7 mesocicles, és a dir, a menys força, més rendiment. En conclusió, durant l’execució del mig esquat, hi ha valors de força adients per rendir millor i lesionar-se menys: de 800 N a 1.050 N i amb càrregues de 80 kg a 90 kg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess baseline predictors and consequences of medication non-adherence in the treatment of pediatric patients with attention-deficit/hyperactivity disorder (ADHD) from Central Europe and East Asia. PATIENTS AND METHODS: Data for this post-hoc analysis were taken from a 1-year prospective, observational study that included a total of 1,068 newly-diagnosed pediatric patients with ADHD symptoms from Central Europe and East Asia. Medication adherence during the week prior to each visit was assessed by treating physicians using a 5-point Likert scale, and then dichotomized into either adherent or non-adherent. Clinical severity was measured by the Clinical Global Impressions-ADHD-Severity (CGI-ADHD) scale and the Child Symptom Inventory-4 (CSI-4) Checklist. Health-Related Quality of Life (HRQoL) was measured using the Child Health and Illness Profile-Child Edition (CHIP-CE). Regression analyses were used to assess baseline predictors of overall adherence during follow-up, and the impact of time-varying adherence on subsequent outcomes: response (defined as a decrease of at least 1 point in CGI), changes in CGI-ADHD, CSI-4, and the five dimensions of CHIP-CE. RESULTS: Of the 860 patients analyzed, 64.5% (71.6% in Central Europe and 55.5% in East Asia) were rated as adherent and 35.5% as non-adherent during follow-up. Being from East Asia was found to be a strong predictor of non-adherence. In East Asia, a family history of ADHD and parental emotional distress were associated with non-adherence, while having no other children living at home was associated with non-adherence in Central Europe as well as in the overall sample. Non-adherence was associated with poorer response and less improvement on CGI-ADHD and CSI-4, but not on CHIP-CE. CONCLUSION: Non-adherence to medication is common in the treatment of ADHD, particularly in East Asia. Non-adherence was associated with poorer response and less improvement in clinical severity. A limitation of this study is that medication adherence was assessed by the treating clinician using a single item question.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isoamyl butyrate production was investigated using free and immobilized lipases by esterification of butyric acid with isoamyl alcohol in a solvent-free system and in an organic media. Among the enzymes studied, Lipozyme TL IM was found to be the most active catalyst in n-hexane as a solvent. The effects of different solvents and the amount of water added on conversion rates were studied. A maximum conversion yield of 80% in n-hexano at 48 h was obtained under the following conditions: 3 g L-1 of Lipozyme TL IM, 30 ºC, 180 rpm of agitation, isoamyl alcohol to butyric acid molar ratio of 1:1 and acid substrate concentration of 0.06 M.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.