1000 resultados para Correção de Vinhete
Resumo:
A monitoring network of atmospheric electric field covering the Vale do Paraiba region was implemented. The sensors were located on different sites with different altitude and geographic topology. The present work reports the study carried on those sensors in order to verify the necessity of using some correction factor to the measured local electric field intensity due to effects of local environment. The measurements were done in continuous 24 hours per day with the data recorded on registers in each device accumulating information during a period of four months. The relation between the electric field values by each sensor was compared to the reference located on Sao Jose dos Campos city using the same period. In a graphical analysis using the local field intensity and the reference, the data were fitted to a straight line obtained by minimum square method. Variation up to 95% was observed between the field values in some sensors. Another method was proposed, comparing the mean values of the electric field in a function of time. The variation in some sensors reached up to 133%. We conclude that the variations are due to local atmospheric conditions and no correction factor is required on the electric field sensors
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
The current reports the case of a young patient with malocclusion Class II division 1 on permanent dentition treated in two stages, rthopedics and orthodontics, respectively. At first, the banded Herbst appliance was used duringa 7 months period, followed by a T4K appliance, Trainer for Kids used as retention, and on the second stage the corrective Orthodontics was performed. The results showed the acquirement of a Class I dental relationship, which was kept stable, with excellent intercuspation, even after 5 years of the removal of the Herbst appliance, as well as the correction of the overjet and the reduction of the facial profile convexity. It can be concluded that the Herbst appliance was very efficient in correcting the Class II malocclusion, long term, also providing a very favorable effect on the facial profile.
Resumo:
This study presents a new treatment technique, that uses TMA archwires with standardized curvatures, associated to intermaxillary elastics, that can do both offer satisfactory results in short period of the treatment time in the open bites cases and in the finishing procedures of the orthodontic treatment.
Resumo:
Bite block is a functional orthodontic appliance that promotes relative intrusion or dental eruption inhibition. The purpose of this study is to present the effects of bite block on the treatment of an open bite case report.
Resumo:
As mordidas cruzadas anteriores e posteriores podem ser tratadas desde as dentaduras decídua e mista. Embora a literatura descreva diversas técnicas para a correção individualizada desses problemas, o tratamento de pacientes com as duas alterações é pouco documentado. O presente artigo relata o tratamento desses problemas com o expansor tipo Haas associado a molas digitais. Essa alternativa apresenta boa previsibilidade, fácil confecção e instalação, e ótima eficiência.
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
The aim of this research was to verify the accuracy of the prediction trace. Records in 15 patients admitted for orthognathic surgical treatment were analysed. Predictive and postoperative positíons of maxilla were compared with linear measurements. Statistically significant difference between predicted and postoperative position were demonstrated, but the prediction trace revealed to be very useful to help in decision of direction of movements, easy to do at low cost
Resumo:
This research evaluated the surgical stabilily in patients with mandibular prognathism and retrognathism in which was used sagital split technic to correct those detormities. Twelve patients were selected from the clinic of only one experienced surgeon. Six patients presenter a Class III 6 a Class II molar relationship. A comparative cefalometric analysis using linear and angular measurements was performed of pre-surgery, imediate pós-surgery and 1 year follow-up. The following conclusions were obtained. 1 The Dal Pont sagital split technic modified by Epker to correct mandibular prognathisn and retroghnatism is a stable technic and must be indicated to correct those deformities. 2 Small relapses are easily corrected by the post-surgical orthodontic treatment. 3 A small over correction is advised in cases of large mandibular advancements or set bascks. 4 In those cases which a large amount of mandibular retrusion on advancement need to be performed, a combination of maxillary and mandibular surgery should be used. Rigid fixation technic is also indicated in those cases
Resumo:
Pós-graduação em Engenharia Civil e Ambiental - FEB
Resumo:
Fundamentation: The correction of maxillary transverse deficiencies involves orthodontic and surgical procedures that can be performed before or after skeletal maturity. The surgically assisted rapid maxillary expansion (SAR ME) is performed by osteotomies through the lateral walls of the maxilla, zygomatic and canines buttresses, palatal and pterygomaxillary sutures, causing the maxillary disjunction. Followed by activation of the expander to the desired over-expansion in order to correct intercuspal later. Objective: The purpose of this study was to discuss the issues involved in the diagnosis of maxillary atresia, SAR ME indications, as well as surgical technique, through a case study. Methods: The male patient, 19 years old, had severe transverse maxillary deficiency with facial pattern III , Class III , with great lip incompetence. The patient underwent general anesthesia in a hospital environment, the osteotomies was done according to the technique described by Epker and Wolford (1980). Postoperatively, the patient underwent activations daily for 15 days and after 6 months, the orthodontist installed fixed orthodontic appliance to prepare the patient to orthognathic surgery later. Conclusion: The diagnosis by clinical evaluation and models study is essential for the indication of SAR ME and this procedure provides good predictability in the correction of transverse deficiency, with minimal morbidity.
Resumo:
Soft tissue recessions frequently cause esthetic disharmony and dissatisfaction. The results of coverage in peri-implant sites, in comparison with soft tissue coverage around a tooth, is less predictable. This clinical report describes the correction of an esthetic problem with a single-tooth implant-supported using a subepithelial connective tissue graft (SCTG) combined with the re-establishment of a new limit of gingival margin, and emergence crown profile. After anamnese and clinical exam it was observed an implant in the region of tooth 22 in vestibular position to alveolar ridge with a recession of 5 mm in its vestibular face. In the first cirurgical procedure the crown and the abutment were removed and a SCTG associated with a coronally positioned flap was performed in order to re-establish the limit of gingival margin. After 90 days, it was observed that the tissue in the implant site showed no adequate volume or thickness. Because of that, another SCTG was performed. The reopening procedure to install the healing cap was performed after 4 weeks. Then the prosthesis was installed. At 180 and 360 days postoperative, the implant adjacent tissue presented regular contour, color compatible with health and absence of bleeding. The patient was satisfied with the esthetic result. According to the clinical results and favorable esthetics it was possible to conclude that the use of ETC to correct an esthetic deficiency may be a feasible approach to establish new and stable peri-implant soft tissue contours.