832 resultados para Cornwaleys, Thomas, d. 1676.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report describes the incidental finding of a calcified ligamentum arteriosum during post-mortem CT examination. The calcification of the ligament was confirmed at autopsy. Subsequent histological examination revealed the presence of cartilage-like and bone-like tissue as well as extended calcification areas. The importance of not confusing this normal post-mortem CT finding with vessel pathology is being emphasized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a case of an individual who stabbed himself through the heart with a large knife. Post mortem computed tomography (CT) and CT-angiography were used to assess the stab channel and to reconstruct the sequence of events. After penetrating injuries to the chest, both the intra-thoracic organs and the injury causing instrument may shift (e.g. from pnemothorax) and render forensic reconstructions more challenging. This case report illustrates the potentials and the pitfalls of CT for the reconstruction of penetrating injures to the chest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although postmortem imaging has gained prominence in the field of forensic medicine, evaluation of the postmortem lung remains problematic. Specifically, differentiation of normal postmortem changes and pathological pulmonary changes is challenging and at times impossible. In this study, five corpses were ventilated using a mechanical ventilator with a pressure of 40 mbar (40.8 cm H(2)O). The ventilation was performed via an endotracheal tube, a larynx mask or a continuous positive airway pressure mask. Postmortem computed tomographic images of the lungs before and with a ventilation of 40 mbar (40.8 cm H(2)O) were evaluated and the lung volumes were measured with segmentation software. Postmortem ventilation led to a clearly visible decrease of both the density in the dependant parts of the lungs and ground glass attenuation, whereas consolidated areas remained unchanged. Furthermore, a mean increase in the lung volume of 2.10 l was seen. Pathological changes such as septal thickening or pulmonary nodules in the lung parenchyma became more detectable with postmortem ventilation. Intracorporal postmortem mechanical ventilation of the lungs appears to be an effective method for enhancing detection of small pathologies of the lung parenchyma as well as for discriminating between consolidation, ground glass attenuation and position-dependent density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present paper, the authors describe a case of fatal thoracic impalement in a victim of a road traffic accident, by penetration of a metal handrail. The driver lost control of his car while overtaking three cars. Due to the force of the vehicle collision with a metal railing, the upper cross bar penetrated the front of the car and subsequently the driver was pierced by the center-pillar in the car. Death occurred at the scene of the accident. Postmortem, computed tomography, computed tomography angiography and a magnetic resonance tomography were performed and revealed severe heart destruction and hemorrhage as cause of death. The present case report shows that postmortem imaging might have value as a screening method to decide whether arising forensic questions can be answered just by imaging like in the presented case or if further examinations such as conventional autopsy are required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The questions of cause and manner of death are the most pressing ones in any forensic investigation. Traditionally, autopsy is the means to provide answers to these questions and despite the increasing use of CT and MR in the post-mortem setting, imaging has usually been an adjunct to forensic autopsy. Here we describe a case where post-mortem CT and MR were performed instead of autopsy, at the request of the responsible public prosecutor. The forensic conclusions derived from imaging, including cause and manner of death were accepted by the legal authorities, thereby setting precedence for future cases. This case represents a landmark in forensic medicine and is another step toward the full realization of minimally invasive forensic autopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this article is to assess the impact of large patient size on the detection of hypovascular liver tumors with MDCT and the effect of a noise filter on image quality and lesion detection in obese patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed tomography (CT) and magnetic resonance (MR) imaging have become important elements of forensic radiology. Whereas the feasibility and potential of CT angiography have long been explored, postmortem MR angiography (PMMRA) has so far been neglected. We tested the feasibility of PMMRA on four adult human cadavers. Technical quality of PMMRA was assessed relative to postmortem CT angiography (PMCTA), separately for each body region. Intra-aortic contrast volumes were calculated on PMCTA and PMMRA with segmentation software. The results showed that technical quality of PMMRA images was equal to PMCTA in 4/4 cases for the head, the heart, and the chest, and in 3/4 cases for the abdomen, and the pelvis. There was a mean decrease in intra-aortic contrast volume from PMCTA to PMMRA of 46%. PMMRA is technically feasible and allows combining the soft tissue detail provided by MR and the information afforded by angiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). RESULTS: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. CONCLUSION: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a case of exhumation, performed to investigate the circumstances and cause of death, one year after burial. Post mortem computed tomography (PMCT) revealed a mass in the pharynx. Imaging directed the subsequent forensic autopsy to careful retrieval of a foreign body. Histological analysis revealed a non-cellular composition. The detection of foreign material in the pharynx and its composition indicated accidental, rather than natural death, secondary to choking on food. This unusual case illustrates how post mortem imaging can significantly contribute to forensic investigation and stresses the importance of interdisciplinary collaboration between forensic pathologists and radiologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. MATERIALS AND METHODS: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. RESULTS: HU values did not change significantly as a function of ROI-shape or -size (p>0.05). Intra-reader reliability reached ICC values >0.929 (p<0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p<0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p<0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p<0.05). CONCLUSION: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurodevelopmental disorders can be caused by many different genetic abnormalities that are individually rare but collectively common. Specific genetic causes, including certain copy number variants and single-gene mutations, are shared among disorders that are thought to be clinically distinct. This evidence of variability in the clinical manifestations of individual genetic variants and sharing of genetic causes among clinically distinct brain disorders is consistent with the concept of developmental brain dysfunction, a term we use to describe the abnormal brain function underlying a group of neurodevelopmental and neuropsychiatric disorders and to encompass a subset of various clinical diagnoses. Although many pathogenic genetic variants are currently thought to be variably penetrant, we hypothesise that when disorders encompassed by developmental brain dysfunction are considered as a group, the penetrance will approach 100%. The penetrance is also predicted to approach 100% when the phenotype being considered is a specific trait, such as intelligence or autistic-like social impairment, and the trait could be assessed using a continuous, quantitative measure to compare probands with non-carrier family members rather than a qualitative, dichotomous trait and comparing probands with the healthy population. Copyright 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.