917 resultados para Corneal irregularity corneal asymmetry


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the efficacy of hyperbaric oxygen therapy in the treatment of alkali-induced corneal burns in an animal model. Methods: Twenty-four rabbits were randomized into a control group (n = 12) and hyperbaric oxygen treatment group (n = 12). After induction of anaesthesia, the alkali burn model was established by application of 1 N sodium hydroxide to one eye of each rabbit. The hyperbaric oxygen treatment group was treated each day for 21 days with hyperbaric oxygen at 2.4 Atmospheres Absolute (ATA) for 1 h. The eyes of the animals were examined daily for 2 weeks and then weekly until the end of the trial. The principal endpoint was that of perforation of the cornea at which time the animals were killed with a lethal dose of either intravenous or intraperitoneal barbiturate and the eyes immediately enucleated and fixed in 10% neutral buffered formalin. All animals in which complete healing took placed were also killed, the eyes removed, fixed and examined histologically. Photographs were taken of the rabbit's eyes at weekly intervals and the area of vascularization and epithelial defects in the hyperbaric and control groups were compared. Results: Equal numbers (seven) of the control and hyperbaric oxygen treated groups had perforated corneas and there was no statistical difference in the mean time to perforation (control 30.1 days; treated 30 days). There was also no statistical difference between the two groups with respect to epithelial defect size. Conclusion: Treatment with hyperbaric oxygen for 1 h daily for 21 days had no beneficial effect on alkali-induced corneal burns.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To compare the efficacy of two forms of eye care (hypromellose and Lacri-Lube combination vs polyethylene/Cling wrap covers) for intensive care patients. Design. Randomised-controlled trial. Setting. University affiliated, tertiary referral hospital. Patients and participants. One hundred ten patients with a reduced or absent blink reflex were followed through until they regained consciousness, were discharged from the facility during study enrolment, died or developed a positive corneal ulcer or eye infection. Interventions. All patients received standard eye cleansing every 2 h. In addition to this, group one (n=60) received a treatment combining hypromellose drops and Lacri-Lube (HL) to each eye every 2 h. Group two (n=50) had polyethylene covers only placed over the eye to create a moisture chamber. Measurements and results. Corneal ulceration was determined using corneal fluorescein stains and mobile slit lamp evaluation, performed daily. No patients had corneal ulceration in the polyethylene cover group, but 4 patients had corneal ulceration in the HL group. Conclusions. Polyethylene covers are as effective as HL in reducing the incidence of corneal damage in intensive care patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The presence of primary cilia in corneal endothelial cells of a range of species from six non-mammalian vertebrate classes (Agnatha, Elasmobranchii, Amphibia, Teleostei, Reptilia, and Aves) is examined by scanning and transmission electron microscopy. Our aim is to assess whether these non-motile cilia protruding into the anterior chamber of the eye are a consistent phylogenetic feature of the corneal endothelium and if a quantitative comparison of their morphology is able to shed any new light on their function. The length (0.42-3.80 mum) and width (0.12-0.44 mum) of the primary cilia varied but were closely allied with previous studies in mammals. However, interspecific differences such as the presence of a terminal swelling in the Teleostei and Amphibia suggest there are functional differences. Approximately one-third of the endothelial cells possess cilia but the extent of protrusion above the cell surface varies greatly, supporting a dynamic process of retraction and elongation. The absence of primary cilia in primitive vertebrates (Agnatha and Elasmobranchii) that possess other mechanisms to control corneal hydration suggests an osmoregulatory and/or chemosensory function. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To report a case of a perforated acute hydrops in a mentally retarded patient that was successfully managed with intracameral sulfur hexafluoride gas and cyanoacrylate tissue adhesive. Methods: Interventional case report. Results: A 14-year-old mentally retarded male patient with keratoconus presented with a perforated acute hydrops. A bandage contact lens was applied. However, following a large emesis 2 days later, the aqueous leak worsened with shallowing of the anterior chamber. Under general anesthesia, sulfur hexafluoride was injected to reform the anterior chamber and cyanoacrylate tissue adhesive was applied to the perforated site and covered by a bandage contact lens and temporary tarsorrhaphy. A follow-up examination at 1 month showed a formed anterior chamber with tissue adhesive in situ and no aqueous leak. Conclusions: The successful use of intracameral sulfur hexafluoride and tissue adhesive in the management of perforated acute hydrops may avoid emergency tectonic penetrating keratoplasty and reduce potential complications in the poorly cooperative patient.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). Methods: The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Results: Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. Conclusions: The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another. © 2003 The College of Optometrists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to investigate the influence of corneal topography and thickness on intraocular pressure (IOP) and pulse amplitude (PA) as measured using the Ocular Blood Flow Analyzer (OBFA) pneumatonometer (Paradigm Medical Industries, Utah, USA). Methods. 47 university students volunteered for this cross-sectional study: mean age 20.4 yrs, range 18 to 28 yrs; 23 male, 24 female. Only the measurements from the right eye of each participant were used. Central corneal thickness and mean corneal radius were measured using Scheimpflug biometry and corneal topographic imaging respectively. IOP and PA measurements were made with the OBFA pneumatonometer. Axial length was measured using A-scan ultrasound, due to its known correlation with these corneal parameters. Stepwise multiple regression analysis was used to identify those components that contributed significant variance to the independent variables of IOP and PA. Results. The mean IOP and PA measurements were 13.1 (SD 3.3) mmHg and 3.0 (SD 1.2) mmHg respectively. IOP measurements made with the OBFA pneumatonometer correlated significantly with central corneal thickness (r = +0.374, p = 0.010), such that a 10 mm change in CCT was equivalent to a 0.30 mmHg change in measured IOP. PA measurements correlated significantly with axial length (part correlate = -0.651, p < 0.001) and mean corneal radius (part correlate = +0.459, p < 0.001) but not corneal thickness. Conclusions. IOP measurements taken with the OBFA pneumatonometer are correlated with corneal thickness, but not axial length or corneal curvature. Conversely, PA measurements are unaffected by corneal thickness, but correlated with axial length and corneal radius. These parameters should be taken into consideration when interpreting IOP and PA measurements made with the OBFA pneumatonometer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To study the prevalence of and relation between refractive and corneal astigmatism in white school children in Northern Ireland and to describe the association between refractive astigmatism and refractive error.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study was designed to evaluate the effects of certain orally active contraceptive steroids on the eye, related to the tolerance of a corneal contact lens. An oestrogen, ethinyloestradiol BP. 0.05 mg, a progestogen, norethisterone acetate BP. 2.50 mg and a control tablet (vitamin C, 50 mg) were utilised. The effect of these preparations on corneal curvature, lacrimal fluid volume and protein composition and directly on corneal lens tolerance was monitored in a group of 23 volunteer patients. The progestogen was found to produce a significant (P≥ 0.05) decrease in tear volume as measured by a 3 minute Schirmer test. A smaller volume reduction was observed with ethinyloestradiol. A normal cornea appears unaffected, within the measurement limits available, by the use of either hormone. However, in the presence of a corneal lens, oestrogen was found to induce substantial corneal steepening, indicative of tissue oedema, during the initial 2-3 weeks of medication. Progestogen occasionally produced a similar effect, which could recur with either hormone shortly after the end of the treatment period. A new method of acrylamide gel electrophoresis was developed for examination of the protein concentration and composition of lacrimal fluid. This allowed much greater resolution of microquantities of unconcentrated fluid than anything previously reported. Quantitation by densitometry has permitted the recording of medication and lens-induced changes in the protein pattern. Tear albumin has been shown to differ from serum albumin and to consist of up to 3 subfractions, 7 further protein fractions may also be resolved. The concentration and probable origin of these proteins have been established and the overall effects of hormone administration described. Individual idiosyncratic responses are also discussed. The study has established tbenature of some effects of contraceptive steroids on the anterior eye, and the probable reasons for resultant corneal lens intolerance.