962 resultados para Continuous glucose monitoring
Resumo:
AIM: Hyperglycaemia is now a recognized predictive factor of morbidity and mortality after coronary artery bypass grafting (CABG). For this reason, we aimed to evaluate the postoperative management of glucose control in patients undergoing cardiovascular surgery, and to assess the impact of glucose levels on in-hospital mortality and morbidity. METHODS: This was a retrospective study investigating the association between postoperative blood glucose and outcomes, including death, post-surgical complications, and length of stay in the intensive care unit (ICU) and in hospital. RESULTS: A total of 642 consecutive patients were enrolled into the study after cardiovascular surgery (CABG, carotid endarterectomy and bypass in the lower limbs). Patients' mean age was 68+/-10 years, and 74% were male. In-hospital mortality was 5% in diabetic patients vs 2% in non-diabetic patients (OR: 1.66, P=0.076). Having blood glucose levels in the upper quartile range (> or =8.8 mmol/L) on postoperative day 1 was independently associated with death (OR: 10.16, P=0.0002), infectious complications (OR: 1.76, P=0.04) and prolonged ICU stay (OR: 3.10, P<0.0001). Patients presenting with three or more hypoglycaemic episodes (<4.1 mmol/L) had increased rates of mortality (OR: 9.08, P<0.0001) and complications (OR: 8.57, P<0.0001). CONCLUSION: Glucose levels greater than 8.8 mmol/L on postoperative day 1 and having three or more hypoglycaemic episodes in the postoperative period were predictive of mortality and morbidity among patients undergoing cardiovascular surgery. This suggests that a multidisciplinary approach may be able to achieve better postoperative blood glucose control.
Resumo:
Summary Forests are key ecosystems of the earth and associated with a large range of functions. Many of these functions are beneficial to humans and are referred to as ecosystem services. Sustainable development requires that all relevant ecosystem services are quantified, managed and monitored equally. Natural resource management therefore targets the services associated with ecosystems. The main hypothesis of this thesis is that the spatial and temporal domains of relevant services do not correspond to a discrete forest ecosystem. As a consequence, the services are not quantified, managed and monitored in an equal and sustainable manner. The thesis aims were therefore to test this hypothesis, establish an improved conceptual approach and provide spatial applications for the relevant land cover and structure variables. The study was carried out in western Switzerland and based primarily on data from a countrywide landscape inventory. This inventory is part of the third Swiss national forest inventory and assesses continuous landscape variables based on a regular sampling of true colour aerial imagery. In addition, land cover variables were derived from Landsat 5 TM passive sensor data and land structure variables from active sensor data from a small footprint laserscanning system. The results confirmed the main hypothesis, as relevant services did not scale well with the forest ecosystem. Instead, a new conceptual approach for sustainable management of natural resources was described. This concept quantifies the services as a continuous function of the landscape, rather than a discrete function of the forest ecosystem. The explanatory landscape variables are therefore called continuous fields and the forest becomes a dependent and function-driven management unit. Continuous field mapping methods were established for land cover and structure variables. In conclusion, the discrete forest ecosystem is an adequate planning and management unit. However, monitoring the state of and trends in sustainability of services requires them to be quantified as a continuous function of the landscape. Sustainable natural resource management iteratively combines the ecosystem and gradient approaches. Résumé Les forêts sont des écosystèmes-clés de la terre et on leur attribue un grand nombre de fonctions. Beaucoup de ces fonctions sont bénéfiques pour l'homme et sont nommées services écosystémiques. Le développement durable exige que ces services écosystémiques soient tous quantifiés, gérés et surveillés de façon égale. La gestion des ressources naturelles a donc pour cible les services attribués aux écosystèmes. L'hypothèse principale de cette thèse est que les domaines spatiaux et temporels des services attribués à la forêt ne correspondent pas à un écosystème discret. Par conséquent, les services ne sont pas quantifiés, aménagés et surveillés d'une manière équivalente et durable. Les buts de la thèse étaient de tester cette hypothèse, d'établir une nouvelle approche conceptuelle de la gestion des ressources naturelles et de préparer des applications spatiales pour les variables paysagères et structurelles appropriées. L'étude a été menée en Suisse occidentale principalement sur la base d'un inventaire de paysage à l'échelon national. Cet inventaire fait partie du troisième inventaire forestier national suisse et mesure de façon continue des variables paysagères sur la base d'un échantillonnage régulier sur des photos aériennes couleur. En outre, des variables de couverture ? terrestre ont été dérivées des données d'un senseur passif Landsat 5 TM, ainsi que des variables structurelles, dérivées du laserscanning, un senseur actif. Les résultats confirment l'hypothèse principale, car l'échelle des services ne correspond pas à celle de l'écosystème forestier. Au lieu de cela, une nouvelle approche a été élaborée pour la gestion durable des ressources naturelles. Ce concept représente les services comme une fonction continue du paysage, plutôt qu'une fonction discrète de l'écosystème forestier. En conséquence, les variables explicatives de paysage sont dénommées continuous fields et la forêt devient une entité dépendante, définie par la fonction principale du paysage. Des méthodes correspondantes pour la couverture terrestre et la structure ont été élaborées. En conclusion, l'écosystème forestier discret est une unité adéquate pour la planification et la gestion. En revanche, la surveillance de la durabilité de l'état et de son évolution exige que les services soient quantifiés comme fonction continue du paysage. La gestion durable des ressources naturelles joint donc l'approche écosystémique avec celle du gradient de manière itérative.
Oral cancer treatments and adherence: medication event monitoring system assessment for capecitabine
Resumo:
Background: Oncological treatments are traditionally administered via intravenous injection by qualified personnel. Oral formulas which are developing rapidly are preferred by patients and facilitate administration however they may increase non-adherence. In this study 4 common oral chemotherapeutics are given to 50 patients, who are still in the process of inclusion, divided into 4 groups. The aim is to evaluate adherence and offer these patients interdisciplinary support with the joint help of doctors and pharmacists. We present here the results for capecitabine. Materials and Methods: The final goal is to evaluate adhesion in 50 patients split into 4 groups according to oral treatments (letrozole/exemestane, imatinib/sunitinib, capecitabine and temozolomide) using persistence and quality of execution as parameters. These parameters are evaluated using a medication event monitoring system (MEMS®) in addition to routine oncological visits and semi-structured interviews. Patients were monitored for the entire duration of treatment up to a maximum of 1 year. Patient satisfaction was assessed at the end of the monitoring period using a standardized questionary. Results: Capecitabine group included 2 women and 8 men with a median age of 55 years (range: 36−77 years) monitored for an average duration of 100 days (range: 5-210 days). Persistence was 98% and quality of execution 95%. 5 patients underwent cyclic treatment (2 out of 3 weeks) and 5 patients continuous treatment. Toxicities higher than grade 1 were grade 2−3 hand-foot syndrome in 1 patient and grade 3 acute coronary syndrome in 1 patient both without impact on adherence. Patients were satisfied with the interviews undergone during the study (57% useful, 28% very useful, 15% useless) and successfully integrated the MEMS® in their daily lives (57% very easily, 43% easily) according to the results obtained by questionary at the end of the monitoring period. Conclusion: Persistence and quality of execution observed in our Capecitabine group of patients were excellent and better than expected compared to previously published studies. The interdisciplinary approach allowed us to better identify and help patients with toxicities to maintain adherence. Overall patients were satisfied with the global interdisciplinary follow-up. With longer follow up better evaluation of our method and its impact will be possible. Interpretation of the results of patients in the other groups of this ongoing trial will provide us information for a more detailed analysis.
Resumo:
Nutritional support in acute renal failure must take into account the patient's catabolism and the treatment of the renal failure. Hypermetabolic failure is common in these patients, requiring continuous renal replacement therapy or daily hemodialysis. In patients with normal catabolism (urea nitrogen below 10 g/day) and preserved diuresis, conservative treatment can be attempted. In these patients, relatively hypoproteic nutritional support is essential, using proteins with high biological value and limiting fluid and electrolyte intake according to the patient's individual requirements. Micronutrient intake should be adjusted, the only buffering agent used being bicarbonate. Limitations on fluid, electrolyte and nitrogen intake no longer apply when extrarenal clearance techniques are used but intake of these substances should be modified according to the type of clearance. Depending on their hemofiltration flow, continuous renal replacement systems require high daily nitrogen intake, which can sometimes reach 2.5 g protein/kg. The amount of volume replacement can induce energy overload and therefore the use of glucose-free replacement fluids and glucose-free dialysis or a glucose concentration of 1 g/L, with bicarbonate as a buffer, is recommended. Monitoring of electrolyte levels (especially those of phosphorus, potassium and magnesium) and of micronutrients is essential and administration of these substances should be individually-tailored.
Resumo:
The use of attractants and larvicides in oviposition traps is of practical interest for the surveillance and control of urban mosquitoes. In addition to increasing the safety of the traps, this combination is essential for an attract-and-kill control strategy based on trapping mosquito eggs. The combination of Bacillus thuringiensis var. israelensis (Bti) and grass infusion (GI) vs. GI alone were tested for their ability to attract in paired BR-OVT traps in the backyards of 10 houses in Recife, Brazil, for a period of 45 days. Results show that females prefer to oviposit in traps containing Bti (363 compared with 251 egg rafts over 45 days). Results from a one-year trial on the efficacy of BR-OVT traps loaded with GI and Bti as a sampling tool to monitor temporal fluctuations in the population densities of Culex quinquefasciatus in an urban environment are also reported. From December 2006-January 2007, one trap per home was installed and maintained for 348 consecutive days in 134-151 houses located in three urban blocks. Throughout the one-year field trial a total of 43,151 Culex egg rafts were collected in the traps. The data show that BR-OVT loaded with GI and Bti is sensitive enough to demonstrate continuous reproductive activity of Cux. quinquefasciatus in the study area throughout the year and to monitor temporal fluctuations in population density.
Resumo:
The change in energy expenditure consecutive to the infusion of glucose/insulin was examined in 17 non-obese (ten young, seven middle-aged) and 27 diabetic and non-diabetic obese subjects by employing the euglycemic insulin clamp technique in conjunction with continuous indirect calorimetry. The obese subjects were divided into four groups according to their response to a 100-g oral glucose test: group A, normal glucose tolerance; group B, impaired glucose tolerance; group C, diabetes with increased insulin response; group D, diabetes with reduced insulin response. The glucose/insulin infusion provoked an increase in energy expenditure in both young and middle-aged controls (+8.2 +/- 1.3 percent and +5.9 +/- 0.5 percent over the preinfusion baseline respectively), but a lower increase in the non-diabetic obese groups A and B (+4.0 +/- 0.7 percent and +2.0 +/- 1.0 percent over the preinfusion baseline respectively, P less than 0.05 and P less than 0.01 vs young controls). However, in the diabetic obese groups C and D, energy expenditure failed to increase in response to the glucose/insulin infusion (mean change: +0.1 +/- 1.0 percent and -2.0 +/- 1.9 percent (P less than 0.01, vs middle-aged) over the preinfusion baseline respectively). When the glucose-induced thermogenesis (GIT) was related to the glucose uptake--taking into account the hepatic glucose production--the GIT was found to be similarly reduced in the diabetics groups (C and D). The net change in the rate of energy expenditure was found to be significantly correlated with the rate of glucose uptake (r = +0.647, n = 44, P less than 0.001) when all the individuals were pooled. In conclusion, this study shows that the low glucose-induced thermogenesis in obese diabetics during glucose insulin infusion is mainly related to a reduced rate of glucose uptake; in addition, inhibition of gluconeogenesis by the glucose/insulin infusion may also contribute to decrease the thermogenic response.
Resumo:
OBJECTIVES: Recommendations for EEG monitoring in the ICU are lacking. The Neurointensive Care Section of the ESICM assembled a multidisciplinary group to establish consensus recommendations on the use of EEG in the ICU. METHODS: A systematic review was performed and 42 studies were included. Data were extracted using the PICO approach, including: (a) population, i.e. ICU patients with at least one of the following: traumatic brain injury, subarachnoid hemorrhage, intracerebral hemorrhage, stroke, coma after cardiac arrest, septic and metabolic encephalopathy, encephalitis, and status epilepticus; (b) intervention, i.e. EEG monitoring of at least 30 min duration; (c) control, i.e. intermittent vs. continuous EEG, as no studies compared patients with a specific clinical condition, with and without EEG monitoring; (d) outcome endpoints, i.e. seizure detection, ischemia detection, and prognostication. After selection, evidence was classified and recommendations developed using the GRADE system. RECOMMENDATIONS: The panel recommends EEG in generalized convulsive status epilepticus and to rule out nonconvulsive seizures in brain-injured patients and in comatose ICU patients without primary brain injury who have unexplained and persistent altered consciousness. We suggest EEG to detect ischemia in comatose patients with subarachnoid hemorrhage and to improve prognostication of coma after cardiac arrest. We recommend continuous over intermittent EEG for refractory status epilepticus and suggest it for patients with status epilepticus and suspected ongoing seizures and for comatose patients with unexplained and persistent altered consciousness. CONCLUSIONS: EEG monitoring is an important diagnostic tool for specific indications. Further data are necessary to understand its potential for ischemia assessment and coma prognostication.
Resumo:
IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.
Resumo:
Continuous respiratory exchange measurements were performed on five women and five men for 1 h before and 6 h after the administration of a milkshake (53% carbohydrates, 30% lipid, and 17% protein energy) given either as a single bolus dose or continuously during 3 h using a nasogastric tube. The energy administered corresponded to 2.3 times the postabsorptive resting energy expenditure. Resting energy expenditure, respiratory quotient, plasma glucose, and insulin concentrations increased sooner and steeper, and plasma free fatty acids levels decreased earlier with the meal ingested as a single dose than with continuous administration. The magnitude of nutrient-induced thermogenesis was greater (P less than 0.01) with the single dose (means +/- SE, 10.0 +/- 0.6%) than with the continuous administration (8.1 +/- 0.5%). The overall (6 h) substrate balances were not significantly different between the two modes of administration. It is concluded that the mode of enteral nutrient administration influences the immediate thermogenic response as well as changes in respiratory quotient, glycemia, and insulinemia; however, the overall nutrient balance was not affected by the mode of enteral nutrient administration.
Resumo:
OBJECTIVE: To compare the effects of sodium bicarbonate and lactate for continuous veno-venous hemodiafiltration (CVVHDF) in critically ill patients. DESIGN AND SETTINGS: Prospective crossed-over controlled trial in the surgical and medical ICUs of a university hospital. PATIENTS: Eight patients with multiple organ dysfunction syndrome (MODS) requiring CVVHDF. INTERVENTION: Each patient received the two buffers in a randomized sequence over two consecutive days. MEASUREMENTS AND RESULTS: The following variables were determined: acid-base parameters, lactate production and utilization ((13)C lactate infusion), glucose turnover (6,6(2)H(2)-glucose), gas exchange (indirect calorimetry). No side effect was observed during lactate administration. Baseline arterial acid-base variables were equal with the two buffers. Arterial lactate (2.9 versus 1.5 mmol/l), glycemia (+18%) and glucose turnover (+23%) were higher in the lactate period. Bicarbonate and glucose losses in CVVHDF were substantial, but not lactate elimination. Infusing (13)C lactate increased plasma lactate levels equally with the two buffers. Lactate clearance (7.8+/-0.8 vs 7.5+/-0.8 ml/kg per min in the bicarbonate and lactate periods) and endogenous production rates (14.0+/-2.6 vs 13.6+/-2.6 mmol/kg per min) were similar. (13)C lactate was used as a metabolic substrate, as shown by (13)CO(2) excretion. Glycemia and metabolic rate increased significantly and similarly during the two periods during lactate infusion. CONCLUSION: Lactate was rapidly cleared from the blood of critically ill patients without acute liver failure requiring CVVHDF, being transformed into glucose or oxidized. Lactate did not exert undesirable effects, except moderate hyperglycemia, and achieved comparable effects on acid-base balance to bicarbonate.
Resumo:
Introduction: Le glucose est le principal substrat énergétique cérébral. Sa concentration dans le cerveau est étroitement liée à la glycémie. Chez le patient neurolésé, du fait de l'augmentation des besoins énergétiques, les réserves cérébrales de glucose sont limitées. Une glycémie suffisamment élevée paraît nécessaire pour assurer un apport adéquat de glucose au cerveau. Objectifs : Le but de cette étude est de mieux comprendre la relation entre glucose cérébral et glycémie lors de lésion cérébrale en analysant la physiologie cérébrale chez des patients neurolésés. Plus précisément nous investiguerons: La relation entre le glucose cérébral et le glucose systémique et son association avec le pronostic vital, l'association entre la neuroglucopénie et différents paramètres cérébraux tel que l'hypertension intracrânienne (HTIC) ou la dysfonction énergétique et finalement l'effet d'une perfusion de glucose 10% sur le glucose cérébral lors d'état de neuroglucopénie. Méthodologie : Analyse d'une base de données prospective comportant des patients souffrant d'un traumatisme crânio-cérébral (TCC) ou une hémorragie sous- arachnoïdienne (HSA) sévères. Les patients comateux sont monitorés par un dispositif intra-parenchymateux avancé, comprenant un cathéter de microdialyse cérébrale et un capteur de PbO2. Résultats : 34 patients consécutifs (moyenne d'âge 42 ans, moyenne de temps jusqu'au début du monitoring : 1.5 jours ± 1 ; moyenne de la durée maximale du monitoring : 6 jours ± 3) ont été étudiés, 25 patients souffrant d'un TCC et 9 patients avec une HSA. Nous avons obtenu une corrélation individuelle entre le glucose cérébral et la glycémie chez 52.9 % des patients. Lorsque la glycémie est inférieure à 5 mmol/l, on observe plus fréquemment des épisodes de neuroglucopénie en comparaison aux valeurs intermédiaires de glycémie (5 - 9.9 mmol/l). Les épisodes d'HTIC (pression intracrânienne (PIC) > 20 mmHg) sont plus fréquemment associés à des épisodes de neuroglucopénie que lorsque la pression intracrânienne est normale 75 % vs. 35%. La dysfonction énergétique est plus souvent associés à des épisodes de neuroglucopénie que lorsque le LPR est normal: 55% contre 36%. Un coefficient de corrélation entre glucose cérébral et glycémie significativement plus élevé a été obtenu chez les survivants que chez les non-survivants (0.1 [interquartile range 0.02- 0.3] contre 0.32 [0.17-0.61]). Chez les patients neuroglucopéniques ayant une corrélation entre glucose cérébral et glycémie, la perfusion de glucose i.v. fait monter le glucose cérébral jusqu'à l'arrêt de la perfusion. Conclusion : Malgré une étroite relation entre glycémie et glucose cérébral en conditions stables, cette relation peut être altérée par des causes cérébrales chez les patients neurolésés montrant que la diminution de la disponibilité du glucose extracellulaire ne résulte pas uniquement d'une hypoglycémie relative mais également de causes cérébrales tel que l'hypoperfusion, l'HTIC ou la dysfonction énergétique.
Resumo:
We previously reported that glucose can be released from GLUT2-null hepatocytes through a membrane traffic-based pathway issued from the endoplasmic reticulum. Here, we further characterized this glucose release mechanism using biosynthetic labeling protocols. In continuous pulse-labeling experiments, we determined that glucose secretion proceeded linearly and with the same kinetics in control and GLUT2-null hepatocytes. In GLUT2-deficient hepatocytes, however, a fraction of newly synthesized glucose accumulated intracellularly. The linear accumulation of glucose in the medium was inhibited in mutant, but not in control, hepatocytes by progesterone and low temperature, as previously reported, but, importantly, also by microtubule disruption. The intracellular pool of glucose was shown to be present in the cytosol, and, in pulse-chase experiments, it was shown to be released at a relatively slow rate. Release was not inhibited by S-4048 (an inhibitor of glucose-6-phosphate translocase), cytochalasin B, or progesterone. It was inhibited by phloretin, carbonyl cyanide p-(trifluoromethoxy)phenylhydrazone, and low temperature. We conclude that the major release pathway segregates glucose away from the cytosol by use of a membrane traffic-based, microtubule-dependent mechanism and that the release of the cytosolic pool of newly synthesized glucose, through an as yet unidentified plasma membrane transport system, cannot account for the bulk of glucose release.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Background and objective: Oral anti-cancer treatments have expanded rapidly over the last years. While taking oral tablets at home ensures a better quality of life, it also exposes patients to the risk of sub-optimal adherence. The objective of this study is to assess how well ambulatory cancer patients execute their prescribed dosing regimen while they are engaged with continuous anti-cancer treatments. Design: This is an on-going longitudinal study. Consecutive patients starting an oral treatment are proposed to enter the study by the oncologist. Then they are referred to the pharmacy, where their oral anticancer treatment is dispensed in a Medication Event Monitoring System (MEMSTM), which records date and time of each opening of the drug container. Electronically compiled dosing history data from the MEMS are summarized and used as feedback during semistructured interviews with the pharmacist, which are dedicated to prevention and management of side effects. Interviews are scheduled before each medical visit. Report of the interview is available to the oncologist via an on-line secured portal. Setting: Seamless care approach between a Multidisciplinary Oncology Center and the Pharmacy of an Ambulatory Care and Community Medicine Department. Main outcome measures: For each patient, the comparison between the electronically compiled dosing history and the prescribed regimen was summarized using a daily binary indicator indicating whether yes or no the patient has taken the medication as prescribed. Results: Study started in March 2008. Among 22 eligible patients, 19 were included (11 men, median age 63 years old) and 3 (14%) refused to participate. 15 patients were prescribed a QD regimen, 3 patients a BID and 1 patient switched from QD to BID during follow-up. Median follow up was 182 days (IQR 72-252). Early discontinuation happened in four patients: side effects (n = 1), psychiatric reasons (n = 1), cancer progression (n = 1) and death (n = 1). On average, the daily number of medications was taken as prescribed in 99% of the follow-up days. Conclusions: Execution of the prescribed dosing regimens was almost perfect during the first 6 months. Maintaining this high degree of regimen execution and persistence over time might however be challenging in this population and need therefore to be confirmed in larger and longer follow-up cohort studies.
Resumo:
Micro-electromechanical systems (MEMS) provide vast improvements over existing sensing methods in the context of structural health monitoring (SHM) of highway infrastructure systems, including improved system reliability, improved longevity and enhanced system performance, improved safety against natural hazards and vibrations, and a reduction in life cycle cost in both operating and maintaining the infrastructure. Advancements in MEMS technology and wireless sensor networks provide opportunities for long-term continuous, real-time structural health monitoring of pavements and bridges at low cost within the context of sustainable infrastructure systems. The primary objective of this research was to investigate the use of MEMS in highway structures for health monitoring purposes. This study focused on investigating the use of MEMS and their potential applications in concrete through a comprehensive literature review, a vendor survey, and a laboratory study, as well as a small-scale field study. Based on the comprehensive literature review and vendor survey, the latest information available on off-the-shelf MEMS devices, as well as research prototypes, for bridge, pavement, and traffic applications were synthesized. A commercially-available wireless concrete monitoring system based on radio-frequency identification (RFID) technology and off-the-shelf temperature and humidity sensors were tested under controlled laboratory and field conditions. The test results validated the ability of the RFID wireless concrete monitoring system in accurately measuring the temperature both inside the laboratory and in the field under severe weather conditions. In consultation with the project technical advisory committee (TAC), the most relevant MEMS-based transportation infrastructure research applications to explore in the future were also highlighted and summarized.