949 resultados para Constant Loading Rate


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, we report the measurement of Rb(2) molecule formation rate constant due to a two body process in a magneto-optical trap as a function of the sample temperature. The ground state molecules are detected by two-photon ionization, through the intermediate a(3)Sigma(+)(u) -> 2(3)Pi(g) molecular band. Our results show that the Rb(2) molecules formed in the MOT could be due to a wave shape resonance, which enhances the molecule formation rate. This effect may be used to enhance the molecule production; and therefore it maybe important to future experiments involving production and trapping of cold ground state molecules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Experimental programs in constant and variable amplitude loading were performed to obtain a x N curves and to study retardation in fatigue crack growth due to overloads. The main aim of this research program was to analyse the effect of overload ratio and number of overload peaks. The effect of underloads, before and after the overload blocks was also studied. The generalised equation of Paris-Erdogan type was used for modelling of obtained data on crack propagation under constant amplitude load.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy adult cats. Procedures - For each cat, 2 experiments were performed (2-week interval). On each study day, anesthesia was induced and maintained with isoflurane; a catheter was placed in a cephalic vein for the administration of lactated Ringer's solution or remifentanil CRIs, and a catheter was placed in the jugular vein for collection of blood samples for blood gas analyses. On the first study day, individual basal MAC (MAC Basal) was determined for each cat. On the second study day, 3 remifentanil CRIs (0.25, 0.5, and 1.0 μg/kg/min) were administered (in ascending order); for each infusion, at least 30 minutes elapsed before determination of MAC (designated as MAC R0.25, MAC R0.5, and MAC R1.0, respectively). A 15-minute washout period was allowed between CRIs. A control MAC (MAC Control) was determined after the last remifentanil infusion. Results - Mean ± SD MAC Basal and MAC Control values at sea level did not differ significantly (1.66 ± 0.08% and 1.52 ± 0.21%, respectively). The MAC values determined for each remifentanil CRI did not differ significantly. However, MAC R0.25, MAC R0.5, and MAC R1.0, were significantly decreased, compared with MAC Basal, by 23.4 ± 79%, 29.8 ± 8.3%, and 26.0 ± 9.4%, respectively. Conclusions and Clinical Relevance - The 3 doses of remifentanil administered via CRI resulted in a similar degree of isoflurane MAC reduction in adult cats, indicating that a ceiling effect was achieved following administration of the lowest dose.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Constant rate infusion (CRI) shows several advantages in balanced anesthesia, such as reduction of requirement for inhaled anesthetics and control of pain. The most commonly used drugs in these protocols are local anesthetics, dissociative, and opioids, which may be administered alone or in combinations. We evaluated the records of 200 dogs that underwent various surgical procedures with anesthetic or analgesic CRI in the perioperative period during 2011 and 2012 at the Veterinary Hospital of Franca University (Unifran), and identified possible complications during the transoperative period. Records evaluated included clinical state, laboratory tests, drugs used in premedication and induction, and CRI protocol. Acepromazine and morphine were the main drugs used in premedication. Propofol was used to induce anesthesia alone or in combination with other agents. We evaluated records of the 25 different CRI protocols. Fentanyl was the main drug employed in CRI, either alone or in combination. There were 128 episodes of anesthetic complications during CRI;the most common were hypotension, hypertension, and tachycardia, which occurred in 43 (32%), 35 (26.3%), and 19 (14.2%) dogs, respectively. Cardiac arrhythmia was reported in only 4 dogs. Signs of respiratory depression were present in dogs treated with 6 different CRI protocols. The consumption of isoflurane (vol %) reduced between 15.7% and 21.05% after 30minutes of the CRI in the fentanyl and fentanyl-lidocaine-ketamine CRI groups (p<0.05). In conclusion, CRI is a valid component of balanced anesthesia in dogs, safe, and has a low incidence of adverse effects. However, future studies are warranted to describe the results of the clinical use of CRI to better characterize and refine this technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The characterization of the hyperbolic power-time (P-tlim) relationship using a two-parameter model implies that exercise tolerance above the asymptote (Critical Power; CP), i.e. within the severe intensity domain, is determined by the curvature (W') of the relationship. The purposes of this study were (1) to test whether the amount of work above CP (W>CP) remains constant for varied work rate experiments of high volatility change and (2) to ascertain whether W' determines exercise tolerance within the severe intensity domain. Following estimation of CP (208 ± 19 W) and W' (21.4 ± 4.2 kJ), 14 male participants (age: 26 ± 3; peak [Formula: see text]: 3708 ± 389 ml.min-1) performed two experimental trials where the work rate was initially set to exhaust 70% of W' in 3 ('THREE') or 10 minutes ('TEN') before being subsequently dropped to CP plus 10 W. W>CP for TEN (104 ± 22% W') and W' were not significantly different (P>0.05) but lower than W>CP for THREE (119 ± 17% W', P<0.05). For both THREE (r = 0.71, P<0.01) and TEN (r = 0.64, P<0.01), a significant bivariate correlation was found between W' and tlim. W>CP and tlim can be greater than predicted by the P-tlim relationship when a decrement in the work rate of high-volatility is applied. Exercise tolerance can be enhanced through a change in work rate within the severe intensity domain. W>CP is not constant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

[EN] Fe(II) oxidation kinetics were studied in seawater and in seawater enriched with exudates excreted by Phaeodactylum tricornutum as an organic ligand model. The exudates produced after 2, 4, and 8 days of culture at 6.21 .. 107, 2.29 .. 108, and 4.98 .. 108 cell L?1 were selected. The effects of pH (7.2?8.2), temperature (5?35 ºC), and salinity (10?36.72) on the Fe(II) oxidation rate were studied. All the data were compared with the results for seawater without exudates (control). The Fe(II) rate constant decreased as a function of culture time and cell concentration in the culture at different pH, temperature, and salinity. All the experimental data obtained in this study were fitted to a polynomial function in order to quantify the fractional contribution of the organic exudates from the diatoms to the Fe(II) oxidation rate in natural seawater. Experimental results showed that the organic exudates excreted by P. tricornutum affect Fe(II) oxidation, increasing the lifetime of Fe(II) in seawater. A kinetic model approach was carried out to account for the speciation of each Fe(II) type together with its contribution to the overall rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Since the development of cyanidation into a highly efficient process for treating gold ores, many papers have been written on its various aspects. Although, there has been much work done on it, the chemistry of the reaction is not yet completely understood.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study quantitatively investigated the analgesic action of a low-dose constant-rate-infusion (CRI) of racemic ketamine (as a 0.5 mg kg(-1) bolus and at a dose rate of 10 microg kg(-1) min(-1)) in conscious dogs using a nociceptive withdrawal reflex (NWR) and with enantioselective measurement of plasma levels of ketamine and norketamine. Withdrawal reflexes evoked by transcutaneous single and repeated electrical stimulation (10 pulses, 5 Hz) of the digital plantar nerve were recorded from the biceps femoris muscle using surface electromyography. Ketamine did not affect NWR thresholds or the recruitment curves after a single nociceptive stimulation. Temporal summation (as evaluated by repeated stimuli) and the evoked behavioural response scores were however reduced compared to baseline demonstrating the antinociceptive activity of ketamine correlated with the peak plasma concentrations. Thereafter the plasma levels at pseudo-steady-state did not modulate temporal summation. Based on these experimental findings low-dose ketamine CRI cannot be recommended for use as a sole analgesic in the dog.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dexmedetomidine and lignocaine IV are used clinically to provide analgesia in horses. The aims of this study were to investigate the antinociceptive effects, plasma concentrations and sedative effects of 2, 4 and 6 µg/kg/h dexmedetomidine IV, with a bolus of 0.96 µg/kg preceding each continuous rate infusion (CRI), and 20, 40 and 60 µg/kg/min lignocaine IV, with a bolus of 550 µg/kg preceding each CRI, in 10 Swiss Warmblood horses. Electrically elicited nociceptive withdrawal reflexes were evaluated by deltoid muscle electromyography. Nociceptive threshold and tolerance were determined by electromyography and behaviour following single and repeated stimulation. Plasma concentrations of drugs were determined by liquid chromatography and mass spectrometry. Sedation was scored on a visual analogue scale. Dexmedetomidine increased nociceptive threshold to single and repeated stimulation for all CRIs, except at 2 µg/kg/h, where no increase in single stimulation nociceptive threshold was observed. Dexmedetomidine increased nociceptive tolerance to single and repeated stimulation at all CRIs. There was large individual variability in dexmedetomidine plasma concentrations and levels of sedation; the median plasma concentration providing antinociceptive effects to all recorded parameters was 0.15 ng/mL, with a range from <0.02 ng/mL (below the lower limit of quantification) to 0.25 ng/mL. Lignocaine increased nociceptive threshold and tolerance to single and repeated stimulation at CRIs of 40 and 60 µg/kg/min, corresponding to plasma lignocaine concentrations >600 ng/mL. Only nociceptive tolerance to repeated stimulation increased at 20 µg/kg/min lignocaine. Lignocaine at 40 µg/kg/min and dexmedetomidine at 4 µg/kg/h were the lowest CRIs resulting in consistent antinociception. Lignocaine did not induce significant sedation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dexmedetomidine, the most selective α2 -adrenoceptor agonist in clinical use, is increasingly being used in both conscious and anaesthetized horses; however, the pharmacokinetics and sedative effects of this drug administered alone as an infusion are not previously described in horses. Seven horses received an infusion of 8 μg dexmedetomidine/kg/h for 150 min, venous blood samples were collected, and dexmedetomidine concentrations were assayed using liquid chromatography-mass spectrometry (LC/MS) and analyzed using noncompartmental pharmacokinetic analysis. Sedation was scored as the distance from the lower lip of the horse to the ground measured in centimetre. The harmonic mean (SD) plasma elimination half-life (Lambda z half-life) for dexmedetomidine was 20.9 (5.1) min, clearance (Cl) was 0.3 (0.20) L/min/kg, and volume of distribution at steady-state (Vdss ) was 13.7 (7.9) L/kg. There was a considerable individual variation in the concentration of dexmedetomidine vs. time profile. The level of sedation covaried with the plasma concentration of dexmedetomidine. This implies that for clinical use of dexmedetomidine constant rate infusion in conscious horses, infusion rates can be easily adjusted to effect, and this is preferable to an infusion at a predetermined value.