936 resultados para Consistent labeling
Resumo:
We study global atmosphere models that are at least as accurate as the hydrostatic primitive equations (HPEs), reviewing known results and reporting some new ones. The HPEs make spherical geopotential and shallow atmosphere approximations in addition to the hydrostatic approximation. As is well known, a consistent application of the shallow atmosphere approximation requires omission of those Coriolis terms that vary as the cosine of latitude and of certain other terms in the components of the momentum equation. An approximate model is here regarded as consistent if it formally preserves conservation principles for axial angular momentum, energy and potential vorticity, and (following R. Müller) if its momentum component equations have Lagrange's form. Within these criteria, four consistent approximate global models, including the HPEs themselves, are identified in a height-coordinate framework. The four models, each of which includes the spherical geopotential approximation, correspond to whether the shallow atmosphere and hydrostatic (or quasi-hydrostatic) approximations are individually made or not made. Restrictions on representing the spatial variation of apparent gravity occur. Solution methods and the situation in a pressure-coordinate framework are discussed. © Crown copyright 2005.
Resumo:
Non-hypothetical valuations obtained from experimental auctions in three United States and two European locations were used to calculate welfare effects of introducing and labeling of genetically modified food. Under certain assumptions, we find that introduction of genetically modified food has been welfare enhancing, on average, for United States consumers but not so for Europeans and while mandatory labeling has been beneficial for European consumers, such a policy would be detrimental in the United States. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
We have developed a general method for multiplexed quantitative proteomics using differential metabolic stable isotope labeling and mass spectrometry. The method was successfully used to study the dynamics of heat-shock response in Arabidopsis thaliana. A number of known heat-shock proteins were confirmed, and some proteins not previously associated with heat shock were discovered. The method is applicable in stable isotope labeling and allows for high degrees of multiplexing.
Resumo:
Stable isotope labeling combined with MS is a powerful method for measuring relative protein abundances, for instance, by differential metabolic labeling of some or all amino acids with 14N and 15N in cell culture or hydroponic media. These and most other types of quantitative proteomics experiments using high-throughput technologies, such as LC-MS/MS, generate large amounts of raw MS data. This data needs to be processed efficiently and automatically, from the mass spectrometer to statistically evaluated protein identifications and abundance ratios. This paper describes in detail an approach to the automated analysis of uniformly 14N/15N-labeled proteins using MASCOT peptide identification in conjunction with the trans-proteomic pipeline (TPP) and a few scripts to integrate the analysis workflow. Two large proteomic datasets from uniformly labeled Arabidopsis thaliana were used to illustrate the analysis pipeline. The pipeline can be fully automated and uses only common or freely available software.
Resumo:
The D 2 dopamine receptor exists as dimers or as higher-order oligomers, as determined from data from physical experiments. In this study, we sought evidence that this oligomerization leads to cooperativity by examining the binding of three radioligands ([H-3] nemonapride, [H-3] raclopride, and [H-3] spiperone) to D 2 dopamine receptors expressed in membranes of Sf9 cells. In saturation binding experiments, the three radioligands exhibited different B-max values, and the B-max values could be altered by the addition of sodium ions to assays. Despite labeling different numbers of sites, the different ligands were able to achieve full inhibition in competition experiments. Some ligand pairs also exhibited complex inhibition curves in these experiments. In radioligand dissociation experiments, the rate of dissociation of [H-3] nemonapride or [H-3] spiperone depended on the sodium ion concentration but was independent of the competing ligand. Although some of the data in this study are consistent with the behavior of a cooperative oligomeric receptor, not all of the data are in agreement with this model. It may, therefore, be necessary to consider more complex models for the behavior of this receptor.
Resumo:
Stable isotope labeling combined with MS is a powerful method for measuring relative protein abundances, for instance, by differential metabolic labeling of some or all amino acids with N-14 and N-15 in cell culture or hydroponic media. These and most other types of quantitative proteomics experiments using high-throughput technologies, such as LC-MS/MS, generate large amounts of raw MS data. This data needs to be processed efficiently and automatically, from the mass spectrometer to statistically evaluated protein identifications and abundance ratios. This paper describes in detail an approach to the automated analysis of Uniformly N-14/N-15-labeled proteins using MASCOT peptide identification in conjunction with the trans-proteomic pipeline (TPP) and a few scripts to integrate the analysis workflow. Two large proteomic datasets from uniformly labeled Arabidopsis thaliana were used to illustrate the analysis pipeline. The pipeline can be fully automated and uses only common or freely available software.
Resumo:
The D 2 dopamine receptor exists as dimers or as higher-order oligomers, as determined from data from physical experiments. In this study, we sought evidence that this oligomerization leads to cooperativity by examining the binding of three radioligands ([H-3] nemonapride, [H-3] raclopride, and [H-3] spiperone) to D 2 dopamine receptors expressed in membranes of Sf9 cells. In saturation binding experiments, the three radioligands exhibited different B-max values, and the B-max values could be altered by the addition of sodium ions to assays. Despite labeling different numbers of sites, the different ligands were able to achieve full inhibition in competition experiments. Some ligand pairs also exhibited complex inhibition curves in these experiments. In radioligand dissociation experiments, the rate of dissociation of [H-3] nemonapride or [H-3] spiperone depended on the sodium ion concentration but was independent of the competing ligand. Although some of the data in this study are consistent with the behavior of a cooperative oligomeric receptor, not all of the data are in agreement with this model. It may, therefore, be necessary to consider more complex models for the behavior of this receptor.
Resumo:
The self-consistent field theory (SCFT) prediction for the compression force between two semi-dilute polymer brushes is compared to the benchmark experiments of Taunton et al. [Nature, 1988, 332, 712]. The comparison is done with previously established parameters, and without any fitting parameters whatsoever. The SCFT provides a significant quantitative improvement over the classical strong-stretching theory (SST), yielding excellent quantitative agreement with the experiment. Contrary to earlier suggestions, chain fluctuations cannot be ignored for normal experimental conditions. Although the analytical expressions of SST provide invaluable aids to understanding the qualitative behavior of polymeric brushes, the numerical SCFT is necessary in order to provide quantitatively accurate predictions.
Resumo:
Quantitative analysis by mass spectrometry (MS) is a major challenge in proteomics as the correlation between analyte concentration and signal intensity is often poor due to varying ionisation efficiencies in the presence of molecular competitors. However, relative quantitation methods that utilise differential stable isotope labelling and mass spectrometric detection are available. Many drawbacks inherent to chemical labelling methods (ICAT, iTRAQ) can be overcome by metabolic labelling with amino acids containing stable isotopes (e.g. 13C and/or 15N) in methods such as Stable Isotope Labelling with Amino acids in Cell culture (SILAC). SILAC has also been used for labelling of proteins in plant cell cultures (1) but is not suitable for whole plant labelling. Plants are usually autotrophic (fixing carbon from atmospheric CO2) and, thus, labelling with carbon isotopes becomes impractical. In addition, SILAC is expensive. Recently, Arabidopsis cell cultures were labelled with 15N in a medium containing nitrate as sole nitrogen source. This was shown to be suitable for quantifying proteins and nitrogen-containing metabolites from this cell culture (2,3). Labelling whole plants, however, offers the advantage of studying quantitatively the response to stimulation or disease of a whole multicellular organism or multi-organism systems at the molecular level. Furthermore, plant metabolism enables the use of inexpensive labelling media without introducing additional stress to the organism. And finally, hydroponics is ideal to undertake metabolic labelling under extremely well-controlled conditions. We demonstrate the suitability of metabolic 15N hydroponic isotope labelling of entire plants (HILEP) for relative quantitative proteomic analysis by mass spectrometry. To evaluate this methodology, Arabidopsis plants were grown hydroponically in 14N and 15N media and subjected to oxidative stress.
Resumo:
There are several advantages of using metabolic labeling in quantitative proteomics. The early pooling of samples compared to post-labeling methods eliminates errors from different sample processing, protein extraction and enzymatic digestion. Metabolic labeling is also highly efficient and relatively inexpensive compared to commercial labeling reagents. However, methods for multiplexed quantitation in the MS-domain (or ‘non-isobaric’ methods), suffer from signal dilution at higher degrees of multiplexing, as the MS/MS signal for peptide identification is lower given the same amount of peptide loaded onto the column or injected into the mass spectrometer. This may partly be overcome by mixing the samples at non-uniform ratios, for instance by increasing the fraction of unlabeled proteins. We have developed an algorithm for arbitrary degrees of nonisobaric multiplexing for relative protein abundance measurements. We have used metabolic labeling with different levels of 15N, but the algorithm is in principle applicable to any isotope or combination of isotopes. Ion trap mass spectrometers are fast and suitable for LC-MS/MS and peptide identification. However, they cannot resolve overlapping isotopic envelopes from different peptides, which makes them less suitable for MS-based quantitation. Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is less suitable for LC-MS/MS, but provides the resolving power required to resolve overlapping isotopic envelopes. We therefore combined ion trap LC-MS/MS for peptide identification with FTICR LC-MS for quantitation using chromatographic alignment. We applied the method in a heat shock study in a plant model system (A. thaliana) and compared the results with gene expression data from similar experiments in literature.