936 resultados para Computer-generated 3D imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shows stages and operations undertaken in revising the New Jersey state base map.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Spinal anaesthesia is the standard of care for elective caesarean delivery. It has advantages over general anaesthesia. However the sympathetic blockade induced by spinal anaesthesia results in an 80 percent incidence of hypotension without prophylactic management. Current evidence supports co-loading with intravenous fluids in conjunction with the use of vasopressors as the most effective way to prevent and treat the hypotension. Phenylephrine is the accepted vasopressor of choice in the parturient. A prophylactic phenylephrine infusion combined with a fluid co-load is proven to be an effective and safe method of maintaining maternal hemodynamic stability. While most published studies have assessed the effectiveness of a prophylactic phenylephrine fixed dose infusion, few studies have assessed the effect of a prophylactic phenylephrine weight adjusted dose infusion on maintaining maternal hemodynamic stability following spinal anesthesia for a cesarean delivery. Objective: To compare the incidence of hypotension between women undergoing elective caesarean section under spinal anaesthesia, receiving prophylactic phenylephrine infusion at a fixed dose of 37.5 micrograms per minute versus a weight adjusted dose of 0.5 micrograms per kilogram per minute. Methods: One hundred and eight patients scheduled for non-urgent caesarean section under spinal anaesthesia were randomized into 2 groups; control group and intervention group using a computer generated table of numbers. Control group; Received prophylactic phenylephrine fixed dose infusion at 37.5 micrograms per minute. Intervention group; Received prophylactic phenylephrine weight adjusted dose infusion at 0.5 micrograms per kilogram per minute Results: The two groups had similar baseline characteristics in terms of ; Age, sex, weight and height. There was a 35.2% incidence of hypotension in the fixed dose group and an 18.6% incidence of hypotension in the weight adjusted dose group. This difference was found to be of borderline statistical significance p-value 0.05, and the difference in the incidence rates between the two groups was found to be statistically significant p= 0.03. The difference in the incidence of reactive hypertension and bradycardia between the two groups was not statistically significant: p-value of 0.19 for reactive hypertension and p-value of 0.42 for the incidence of bradycardia. There was also no statistically significant difference in the use of phenylephrine boluses, use of atropine, intravenous fluid used and the number of times the infusion was stopped. Conclusion: Among this population, the incidence of hypotension was significantly less in the weight adjusted dose group than in the fixed dose group. There was no difference in the number of physician interventions required to keep the blood pressure within 20% of baseline, and no difference in the proportion of reactive hypertension or bradycardia between the two groups. Administering prophylactic phenylephrine infusion at a weight adjusted dose of 0.5 micrograms per kilogram per minute results in a lower incidence of hypotension compared to its administration at a fixed dose of 37.5 micrograms per minute.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shows Paterson city territory, county boundaries, and location of cities and towns in the surrounding region. Does not show roads or streets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In quantitative risk analysis, the problem of estimating small threshold exceedance probabilities and extreme quantiles arise ubiquitously in bio-surveillance, economics, natural disaster insurance actuary, quality control schemes, etc. A useful way to make an assessment of extreme events is to estimate the probabilities of exceeding large threshold values and extreme quantiles judged by interested authorities. Such information regarding extremes serves as essential guidance to interested authorities in decision making processes. However, in such a context, data are usually skewed in nature, and the rarity of exceedance of large threshold implies large fluctuations in the distribution's upper tail, precisely where the accuracy is desired mostly. Extreme Value Theory (EVT) is a branch of statistics that characterizes the behavior of upper or lower tails of probability distributions. However, existing methods in EVT for the estimation of small threshold exceedance probabilities and extreme quantiles often lead to poor predictive performance in cases where the underlying sample is not large enough or does not contain values in the distribution's tail. In this dissertation, we shall be concerned with an out of sample semiparametric (SP) method for the estimation of small threshold probabilities and extreme quantiles. The proposed SP method for interval estimation calls for the fusion or integration of a given data sample with external computer generated independent samples. Since more data are used, real as well as artificial, under certain conditions the method produces relatively short yet reliable confidence intervals for small exceedance probabilities and extreme quantiles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determining effective hydraulic, thermal, mechanical and electrical properties of porous materials by means of classical physical experiments is often time-consuming and expensive. Thus, accurate numerical calculations of material properties are of increasing interest in geophysical, manufacturing, bio-mechanical and environmental applications, among other fields. Characteristic material properties (e.g. intrinsic permeability, thermal conductivity and elastic moduli) depend on morphological details on the porescale such as shape and size of pores and pore throats or cracks. To obtain reliable predictions of these properties it is necessary to perform numerical analyses of sufficiently large unit cells. Such representative volume elements require optimized numerical simulation techniques. Current state-of-the-art simulation tools to calculate effective permeabilities of porous materials are based on various methods, e.g. lattice Boltzmann, finite volumes or explicit jump Stokes methods. All approaches still have limitations in the maximum size of the simulation domain. In response to these deficits of the well-established methods we propose an efficient and reliable numerical method which allows to calculate intrinsic permeabilities directly from voxel-based data obtained from 3D imaging techniques like X-ray microtomography. We present a modelling framework based on a parallel finite differences solver, allowing the calculation of large domains with relative low computing requirements (i.e. desktop computers). The presented method is validated in a diverse selection of materials, obtaining accurate results for a large range of porosities, wider than the ranges previously reported. Ongoing work includes the estimation of other effective properties of porous media.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Artes, Programa de Pós-Graduação em Arte, 2016.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La Reabsorción radicular externa apical es un proceso inflamatorio común asociado con el tratamiento de ortodoncia. El objetivo de este estudio fue comparar la magnitud de la RREA de los incisivos y caninos superiores e inferiores en pacientes sometidos a la fase inicial del tratamiento de ortodoncia con tres diferentes tipos de brackets. La muestra consistió en 23 casos de pacientes con edades comprendidas entre 12 y 27 años, fueron divididos aleatoriamente en 3 grupos. Grupo I (n=9; 5 mujeres y 4 varones), utilizando brackets pasivos de autoligado Damon Q Grupo II (n= 8; 4 mujeres y 4 varones) utilizando brackets convencionales prescripción Roth y MBT. Grupo III (n=6; 4 mujeres y 2 varones) utilizando brackets Biofuncional QR. Se analizaron 264 dientes (caninos e incisivos superiores e inferiores) mediante el uso de tomografía computarizada de haz cónico (NewTom VGi Cone Beam 3D Imaging), con el escáner NNT Viewer (versión 4.6 NewTom). Los resultados obtenidos indican que la media de reabsorción se mostró distinta para los diferentes protocolos de tratamiento, así como diferente de acuerdo a la pieza analizada, sin embargo, la prueba de ANOVA no encontró diferencias estadísticamente significativas al comparar la media de reabsorción de cada pieza por tipo de brackets empleados o tratamiento realizado (p >0,05). Se concluye que la RREA se ha producido en todos los dientes evaluados, durante los 6 primeros meses de tratamiento y el diseño del bracket (autoligado pasivo, convencional o QR) no influye en el grado de reabsorción radicular.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

AbstractObjective:To compare the accuracy of computer-aided ultrasound (US) and magnetic resonance imaging (MRI) by means of hepatorenal gradient analysis in the evaluation of nonalcoholic fatty liver disease (NAFLD) in adolescents.Materials and Methods:This prospective, cross-sectional study evaluated 50 adolescents (aged 11–17 years), including 24 obese and 26 eutrophic individuals. All adolescents underwent computer-aided US, MRI, laboratory tests, and anthropometric evaluation. Sensitivity, specificity, positive and negative predictive values and accuracy were evaluated for both imaging methods, with subsequent generation of the receiver operating characteristic (ROC) curve and calculation of the area under the ROC curve to determine the most appropriate cutoff point for the hepatorenal gradient in order to predict the degree of steatosis, utilizing MRI results as the gold-standard.Results:The obese group included 29.2% girls and 70.8% boys, and the eutrophic group, 69.2% girls and 30.8% boys. The prevalence of NAFLD corresponded to 19.2% for the eutrophic group and 83% for the obese group. The ROC curve generated for the hepatorenal gradient with a cutoff point of 13 presented 100% sensitivity and 100% specificity. As the same cutoff point was considered for the eutrophic group, false-positive results were observed in 9.5% of cases (90.5% specificity) and false-negative results in 0% (100% sensitivity).Conclusion:Computer-aided US with hepatorenal gradient calculation is a simple and noninvasive technique for semiquantitative evaluation of hepatic echogenicity and could be useful in the follow-up of adolescents with NAFLD, population screening for this disease as well as for clinical studies.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We develop a method for obtaining 3D polarimetric integral images from elemental images recorded in low light illumination conditions. Since photon-counting images are very sparse, calculation of the Stokes parameters and the degree of polarization should be handled carefully. In our approach, polarimetric 3D integral images are generated using the Maximum Likelihood Estimation and subsequently reconstructed by means of a Total Variation Denoising filter. In this way, polarimetric results are comparable to those obtained in conventional illumination conditions. We also show that polarimetric information retrieved from photon starved images can be used in 3D object recognition problems. To the best of our knowledge, this is the first report on 3D polarimetric photon counting integral imaging.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

For embolized cerebral aneurysms, the initial occlusion rate is the most powerful parameter to predict aneurysm rerupture and recanalization. However, the occlusion rate is only estimated subjectively in clinical routine. To minimize subjective bias, computer occlusion-rating (COR) was successfully validated for 2D images. To minimize the remaining inaccuracy of 2D-COR, COR was applied to 1.5T 3D MR imaging.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

OBJECT: The aim of our study was to demonstrate the image quality of the new device using human cadavers, extending the horizon of available imaging modalities in forensic medicine. MATERIALS AND METHODS: Six human cadavers were examined, revealing C-arm data sets of the head, neck thorax, abdomen and pelvis. High-resolution mode was performed with 500 fluoroscopy shots during a 190 degrees orbital movement with a constant tube voltage of 100 kV and a current of 4.6 mA. Based on these data sets subsequent three-dimensional reconstructions were generated. RESULTS: Reconstructed data sets revealed high-resolution images of all skeletal structures in a near-CT quality. The same image quality was available in all reconstruction planes. Artefacts caused by restorative dental materials are less accentuated in CBCT data sets. The system configuration was not powerful enough to generate sufficient images of intracranial structures. CONCLUSION: After the here-demonstrated encouraging preliminary results, the forensic indications that would be suitable for imaging with a 3D C-arm have to be defined. Promising seems the visualization local limited region of interest as the cervical spine or the facial skeleton.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Axial X-ray Computed tomography (CT) scanning provides a convenient means of recording the three-dimensional form of soil structure. The technique has been used for nearly two decades, but initial development has concentrated on qualitative description of images. More recently, increasing effort has been put into quantifying the geometry and topology of macropores likely to contribute to preferential now in soils. Here we describe a novel technique for tracing connected macropores in the CT scans. After object extraction, three-dimensional mathematical morphological filters are applied to quantify the reconstructed structure. These filters consist of sequences of so-called erosions and/or dilations of a 32-face structuring element to describe object distances and volumes of influence. The tracing and quantification methodologies were tested on a set of undisturbed soil cores collected in a Swiss pre-alpine meadow, where a new earthworm species (Aporrectodea nocturna) was accidentally introduced. Given the reduced number of samples analysed in this study, the results presented only illustrate the potential of the method to reconstruct and quantify macropores. Our results suggest that the introduction of the new species induced very limited chance to the soil structured for example, no difference in total macropore length or mean diameter was observed. However. in the zone colonised by, the new species. individual macropores tended to have a longer average length. be more vertical and be further apart at some depth. Overall, the approach proved well suited to the analysis of the three-dimensional architecture of macropores. It provides a framework for the analysis of complex structures, which are less satisfactorily observed and described using 2D imaging. (C) 2002 Elsevier Science B.V. All rights reserved.