802 resultados para Computer display
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2015
Resumo:
The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.
Resumo:
With the aid of the cobalt labelling technique, frog spinal cord motor neuron dendrites of the subpial dendritic plexus have been identified in serial electron micrographs. Computer reconstructions of various lengths (2.5-9.8 micron) of dendritic segments showed the contours of these dendrites to be highly irregular, and to present many thorn-like projections 0.4-1.8 micron long. Number, size and distribution of synaptic contacts were also determined. Almost half of the synapses occurred at the origins of the thorns and these synapses had the largest contact areas. Only 8 out of 54 synapses analysed were found on thorns and these were the smallest. For the total length of reconstructed dendrites there was, on average, one synapse per 1.2 micron, while 4.4% of the total dendritic surface was covered with synaptic contacts. The functional significance of these distal dendrites and their capacity to influence the soma membrane potential is discussed.
Resumo:
Therapeutic drug monitoring (TDM) aims to optimize treatments by individualizing dosage regimens based on the measurement of blood concentrations. Dosage individualization to maintain concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculations currently represent the gold standard TDM approach but require computation assistance. In recent decades computer programs have been developed to assist clinicians in this assignment. The aim of this survey was to assess and compare computer tools designed to support TDM clinical activities. The literature and the Internet were searched to identify software. All programs were tested on personal computers. Each program was scored against a standardized grid covering pharmacokinetic relevance, user friendliness, computing aspects, interfacing and storage. A weighting factor was applied to each criterion of the grid to account for its relative importance. To assess the robustness of the software, six representative clinical vignettes were processed through each of them. Altogether, 12 software tools were identified, tested and ranked, representing a comprehensive review of the available software. Numbers of drugs handled by the software vary widely (from two to 180), and eight programs offer users the possibility of adding new drug models based on population pharmacokinetic analyses. Bayesian computation to predict dosage adaptation from blood concentration (a posteriori adjustment) is performed by ten tools, while nine are also able to propose a priori dosage regimens, based only on individual patient covariates such as age, sex and bodyweight. Among those applying Bayesian calculation, MM-USC*PACK© uses the non-parametric approach. The top two programs emerging from this benchmark were MwPharm© and TCIWorks. Most other programs evaluated had good potential while being less sophisticated or less user friendly. Programs vary in complexity and might not fit all healthcare settings. Each software tool must therefore be regarded with respect to the individual needs of hospitals or clinicians. Programs should be easy and fast for routine activities, including for non-experienced users. Computer-assisted TDM is gaining growing interest and should further improve, especially in terms of information system interfacing, user friendliness, data storage capability and report generation.
Resumo:
En este proyecto se muestran las posibilidades de la visión estéreo para la visualización en monitores tanto de objetos simples como de grandes escenarios, así como su aplicación en juegos o en otros ámbitos como el cine, la geología e incluso la medicina. Para el desarrollo se ha usado una tarjeta con soporte 3d como la Nvidia 7600GT y una pantalla con una tasa de frecuencia alta como una ACER 19 pulgadas a 100Hz. Los resultados sobre la visualización han sido extraídos de las opiniones de un grupo de 20 personas, de diversas profesiones, no relacionadas con los gráficos por ordenador.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
L’objectiu del projecte consisteix en l’estudi, simulació i implantació d’un conjunt d’aplicacions que permeten tenir un control sobre possibles problemes que puguin succeir a la nostra xarxa. Aquest projecte és la solució als problemes de detecció d’errors en el funcionament de les infraestructures de networking de les que disposen els nostres clients.
Resumo:
The CIPA programme is a collaborative project including two entomologists from France and seven South and Central America countries. Its objective is the development of an expert system for computer aided identification of phlebotomine sandflies from the Americas. It also includes the formation of data bases for bibliographic, taxonomic and biogeographic data. Participant consensus on taxonomic prerequisites, standardization in bibliographic data collections and selection of descriptive variables for the final programme has been established through continous communication among participants and annual meetings. The adopted check-list of American sandflies presented here includes 386 specific taxa, ordered into genera and 28 sub-genera or species groups.
Resumo:
Replacement of the hyperimmune anti-Rhesus (Rh) D immunoglobulin, currently used to prevent haemolytic disease of the newborn, by fully recombinant human anti-RhD antibodies would solve the current logistic problems associated with supply and demand. The combination of phage display repertoire cloning with precise selection procedures enables isolation of specific genes that can then be inserted into mammalian expression systems allowing production of large quantities of recombinant human proteins. With the aim of selecting high-affinity anti-RhD antibodies, two human Fab libraries were constructed from a hyperimmune donor. Use of a new phage panning procedure involving bromelin-treated red blood cells enabled the isolation of two high-affinity Fab-expressing phage clones. LD-6-3 and LD-6-33, specific for RhD. These showed a novel reaction pattern by recognizing the D variants D(III), D(IVa), D(IVb), D(Va), D(VI) types I and II. D(VII), Rh33 and DFR. Full-length immunoglobulin molecules were constructed by cloning the variable regions into expression vectors containing genomic DNA encoding the immunoglobulin constant regions. We describe the first, stable, suspension growth-adapted Chinese hamster ovary (CHO) cell line producing a high affinity recombinant human IgG1 anti-RhD antibody adapted to pilot-scale production. Evaluation of the Fc region of this recombinant antibody by either chemiluminescence or antibody-dependent cell cytotoxicity (ADCC) assays demonstrated macrophage activation and lysis of red blood cells by human lymphocytes. A consistent source of recombinant human anti-RhD immunoglobulin produced by CHO cells is expected to meet the stringent safety and regulatory requirements for prophylactic application.
Resumo:
Dès le milieu des années 1920 et le développement des premiers prototypes fonctionnels, la télévision se fait objet d'exposition. La nouvelle technologie est montrée à des foires industrielles et dans des grands magasins, à des expositions universelles et nationales : exposée, la télévision devient un mass media avant même qu'elle ne diffuse des émissions régulières. En étudiant les présentations publiques de la télévision en Allemagne, en Grande-Bretagne et aux Etats-Unis entre 1928 - date de l'ouverture des premières expositions annuelles dans les trois pays - et 1939 - moment de l'interruption de celles-ci suite à l'éclatement de la Deuxième Guerre mondiale - Television before TV montre que les lieux où le médium rencontre son premier public constituent les mêmes espaces qui, rétrospectivement, permettent de comprendre son avènement. Cette recherche propose ainsi de nouvelles pistes pour l'histoire des médias en interrogeant la définition de la télévision en tant que médium du privé. Elle rappelle l'importance historique de l'espace public pour la « vision à distance » et, dépassant la perspective nationale, reconstitue les différences et similarités techniques, médiatiques et institutionnelles de la télévision allemande, américaine et britannique dans l'entre-deux-guerres. Développée dans un contexte qui est simultanément nationaliste et nourri d'échanges et de compétitions internationales, la télévision sert de comparatif dans les rivalités entre pays, mais stimule également la circulation de savoir-faire et de personnes. Sa forte valeur symbolique comme emblème du progrès scientifique et, dans le cas allemand, comme preuve de la modernité du régime national-socialiste se traduit dans les salles d'expositions par des scénographies souvent innovatrices, dont les photographies et descriptions se propagent au-delà de la presse locale. Au centre d'un réseau discursif et représentationnel, les expositions jouent alors un rôle essentiel pour la construction sociale, politique et culturelle de la télévision. Remplaçant l'analyse de textes audiovisuels par l'étude de la machine exposée, ma recherche reformule la question bazinienne de qu'est-ce que la télévision ? pour demander où le médium se situe-t-il ? Cette prémisse méthodologique permet de contourner une évaluation qualitative de la technologie qui déplorerait ses multiples imperfections, et éclaire d'un nouveau jour des dispositifs télévisuels qui, même sans programme, intègrent un univers voué à la culture de consommation et du loisir.
Resumo:
New anti-cancer agents are being developed that specifically recognise tumour cells. Recognition is dependent upon the enhanced expression of antigenic determinants on the surface of tumour cells. The tumour exposure and the extracellular accessibility of the mucin MUC-1 make this marker a suitable target for tumour diagnosis and therapy. We isolated and characterised six human scFv antibody fragments that bound to the MUC-1 core protein, by selecting a large naive human phage display library directly on a MUC-1-expressing breast carcinoma cell line. Their binding characteristics have been studied by ELISA, FACS and indirect immunofluorescence. The human scFv antibody fragments were specific for the tandem repeat region of MUC-1 and their binding is inhibited by soluble antigen. Four human scFv antibody fragments (M2, M3, M8, M12) recognised the hydrophilic PDTRP region of the MUC-1 core protein, which is thought to be an immunodominant region. The human scFv antibody fragments were stable in human serum at 37 degrees C and retained their binding specificity. For imaging or targeting to tumours over-expressing MUC-1, it might be feasible to use these human scFv, or multivalent derivatives, as vehicles to deliver anti-cancer agents.
Resumo:
Aquest projecte es centra en l’àmbit de l’automoció, i la seva finalitat es ampliar la informació que proporciona el fabricant d’un vehicle als usuaris. Un dels punts claus del sistema es que aquest quedi completament integrat, per tant, utilitza dispositius externs inclosos al vehicle com ara el display que anteriorment s’utilitzava per a mostrar informació del radiocasset, i una maneta amb dos botons utilitzada per al control del sistema. El sistema mostra diferents tipus d’informació com ara la velocitat instantània del vehicle, revolucions del motor, velocitat màxima, distància parcial recorreguda, hora i data. A més de mostrar informació, aquest es capaç d’emmagatzemar-la en un suport extraïble per a una posterior explotació a un ordinador convencional. El sistema no està pensat per a ser un projecte tancat, sinó que esta dissenyat per a ser ampliat en quant a funcionalitats, i per tant aquest projecte es considera una primera versió.
Resumo:
IPH responded to the Department of Justice, Equality and Defence review of the voluntary Code of Practice for the display and sale of alcohol in supermarkets, convenience stores and similar mixed trading outlets. The voluntary Code was introduced in 2008 as an alternative to the statutory rules for structural separation of alcohol products in mixed trading outlets which are set out in section 9 of the Intoxicating Liquor Act 2008. Interested bodies and individuals were invited to submit comments on the Compliance Report for 2011 and on the effectiveness of the voluntary approach to structural separation by 20th December 2011. The Minister said he intended to also seek the views of the Minister for Health and the Joint Oireachtas Committee on Justice, Defence and Equality before reaching any decision on whether to bring the statutory rules in the 2008 Act into operation.