1000 resultados para Compuestos aromáticos policíclicos
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) constitute a family of compounds characterized by having two or more condensed aromatic rings and for being a class of substances that are widely distributed in the environment as a complex mixture, being very persistent in the environment due to its low solubility in water. The application of chemometric methods to analytical chemistry has provided excellent results in studying the solubility of PAHs in aqueous media in order to understand the mechanisms involved in environmental contamination. The method consists in analyzing the solubilization of PAHs from diesel oil in water varying parameters such as stirring time, volume of oil added and pH, using a full factorial design of two levels and three factors. PAHs were extracted with n-hexane and analyzed by fluorescence spectroscopy because they have molecular characteristics fluorescent due to the large number of condensed rings and links, and gas chromatography coupled to a mass spectrometer (GC-MS). The results of fluorescence analysis showed that only the stirring time and pH influenced the solubility of PAHs in diesel fuel. How is a non-selective technique for the study of fluorescence was performed on form and semi-quantitative. And for the chromatographic analysis the results showed that the solubility of the different PAHs is influenced differently so that you can classify them into groups by the results of the effects
Resumo:
Volatile Organic Compounds are pollutants coming mainly from activities that use fossil fuels. Within this class are the BTEX (benzene, toluene, ethylbenzene and xylenes) compounds that are considered hazardous. Among the various existing techniques for degradation of pollutants, there is advanced oxidation using H2O2 generating hidoxil radical ( OH). In this work, the mesoporous material of MCM-41 was synthesized by hydrothermal method and then was used as support, the impregnation of titanium by the method of synthesis with excess solvent to obtain the catalyst Ti-MCM-41. The catalyst was used in the reaction catalyzed removal of BTEX in water using H2O2 as oxidant. The materials were characterized by: XRD, TG/DTG, FTIR, nitrogen adsorption-desorption and FRX-EDX, in order to verify the method of impregnation of the mesoporous titanium support was effective. Catalytic tests were carried out in reactors of 20 mL containing BTEX (100.0 μg/L), H2O2 (2.0 M) and Ti-MCM-41 (2.0 g/L) in acid medium. The reaction occurred for 5 h at 60 °C and analysis were performed by gas chromatography with photoionization detector and static headspace sampler. The characterizations have proven the effectiveness of the synthesis method used and the incorporation of titanium lt in the support. The catalytic tests showed satisfactory results with conversion of more than 95 % for the studied compounds, where the catalyst 48% Ti-MCM-41 showed a higher removal efficiency of the compounds under study
Resumo:
The synthesis of MFI-type zeolite membranes was carried by the process in situ or hydrothermal crystallization. We studied the homogenization time of the room temperature and gel filtration just before the crystallization step performed out in an oven, thus obtaining a more uniform zeolite film. The powder synthesized zeolite (structure type MFI, Silicalite) was characterized by several complementary techniques such as Xray diffraction (XRD), scanning electron microscopy (SEM), thermal analysis, temperature programmed desorption (TPD), Fourier Transform infrared spectroscopy (FTIR) and textural analysis by nitrogen adsorption (specific surface area). For the purpose of evaluating the quality of the layer supported on the ceramic support, N2 permeation tests were carried starting from room temperature to 600 °C, where values were observed values more appropriate permeation from 200 °C. With the data obtained, it was made into a graph of temperature versus permeation function, the curve of surface diffusion was found. For scanning electron microscopy, we observed the formation of homogeneous crystals and the zeolite film showed no fissures or cracks, indicating that the process of synthesis and subsequent treatments not damaged the zeolite layer on the support. Carried permeation studies were found values ranging from 3.64x10-6 to 3.78x10-6, 4.71x10-6 to 5.02x10-6, to pressures 20 and 25 psi, respectively. And the mixture xylenes/N2 values were between 5.39x10-6 to 5.67x10-6 and 8.13x10-6 to 8.36x10-6, also for pressures of 20 and 25 psi. The values found for the separation factor were 15.22 at 400 °C in the first experiment and 1.64 for the second experiment at a temperature of 150 °C. It is concluded that the Silicalite membrane was successfully synthesized and that it is effective in the separation of binary mixtures of xylenes
Resumo:
This work is directed to the treatment of organic compounds present in produced water from oil using electrochemical technology. The water produced is a residue of the petroleum industry are difficult to treat , since this corresponds to 98 % effluent from the effluent generated in the exploration of oil and contains various compounds such as volatile hydrocarbons (benzene, toluene, ethylbenzene and xylene), polycyclic aromatic hydrocarbons (PAHs), phenols, carboxylic acids and inorganic compounds. There are several types of treatment methodologies that residue being studied, among which are the biological processes, advanced oxidation processes (AOPs), such as electrochemical treatments electrooxidation, electrocoagulation, electrocoagulation and eletroredution. The electrochemical method is a method of little environmental impact because instead of chemical reagents uses electron through reactions of oxide-reducing transforms toxic substances into substances with less environmental impact. Thus, this paper aims to study the electrochemical behavior and elimination of the BTX (benzene, toluene and xylene) using electrode of Ti/Pt. For the experiment an electrochemical batch system consists of a continuous source, anode Ti/Pt was used, applying three densities of current (1 mA/cm2, 2,5 mA/cm2 and 5 mA/cm2). The synthetic wastewater was prepared by a solution of benzene, toluene and xylene with a concentration of 5 ppm, to evaluate the electrochemical behavior by cyclic voltammetry and polarization curves, even before assessing the removal of these compounds in solution by electrochemical oxidation. The behavior of each of the compounds was evaluated by the use of electrochemical techniques indicate that each of the compounds when evaluated by cyclic voltammetry showed partial oxidation behavior via adsorption to the surface of the Ti/Pt electrode. The adsorption of each of the present compounds depends on the solution concentration but there is the strong adsorption of xylene. However, the removal was confirmed by UV-Vis, and analysis of total organic carbon (TOC), which showed a percentage of partial oxidation (19,8 % - 99,1 % TOC removed), confirming the electrochemical behavior already observed in voltammetry and cyclic polarization curves
Resumo:
Os hidrocarbonetos policíclicos aromáticos (HPAs) estão associados ao aumento da incidência de diversos tipos de cânceres no homem. Essas moléculas são formadas principalmente na queima incompleta de matéria orgânica, sendo encontradas em todos os compartimentos ambientais. Órgãos regulamentadores das áreas ambiental e de saúde ocupacional consideram 17 HPAs como contaminantes atmosféricos prioritários. Este trabalho apresenta um método para análise simultânea destes HPAs utilizando-se a cromatografia a gás acoplada à espectrometria de massas operando no modo tandem (GC-MS/MS). Os limites de detecção e quantificação do método mostraram-se até 5 vezes inferiores aos obtidos no método GC-MS (SCAN). O método mostrou-se seletivo para análise de HPAs em extratos de amostras de material particulado atmosférico. Uma análise comparativa de dois sistemas de solventes (diclorometano/metanol 4:1 v/v e hexano/acetona 1:1 v/v) para a extração de HPAs, utilizando amostras de material particulado atmosférico, revelou que ambas as misturas de solventes possuem poder de extração semelhante. Os resultados sugerem que é possível realizar extração de HPAs de material particulado atmosférico em ultra-som com a mistura hexano/acetona (1:1), que é menos tóxica em relação à mistura diclorometano/metanol (4:1), bastante utilizada nestas análises, sem perdas significativas na exatidão do método.
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Pós-graduação em Ciências Biológicas (Biologia Celular e Molecular) - IBRC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IBILCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)