816 resultados para Composite Physical Function Scale
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective. To identify and quantify the camphorquinone (CQ) used in different brands of composite resins as a function of the shade analyzed.Materials and methods. Filtek Z250 A3 (FZA3), Filtek Z-250 Incisal (FZI), Pyramid Enamel A1 (PEA1), Pyramid Enamel Translucent (PET), Filtek Supreme A3E (FSA3) and Filtek Supreme GT (FSGT) were used. Five hundred milligrams of each resin were weighed and then dissolved in 1.0 ml of methanol. The samples were centrifuged to accelerate the sedimentation of the inorganic particles. 0.8 ml of the supernatant solution was collected with a pipette and assessed under gas chromatography coupled to the mass spectrometer (GC-MS). The results were compared to pure CQ solutions, used as a standard. Student's t-test, (p = 0.05) significant at the level of 5%, compared the results of each brand shade.Results. A smaller amount of camphorquinone was found in Filtek Z-250 (FZI) resin incisal shade when compared to (FZA3) A3 shade. on the other hand, Filtek Supreme resin featured a statistically larger camphorquinone amount in the incisal shade. in Pyramid Enamel resin camphorquinone was found only in shade Al, while the photoinitiator used in the Translucent shade was not identified.Significance. Based on the data obtained, it is possible to conclude that a single composite resin brand may feature differences in amount and type of photoinitiator used. (C) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Application of high temperature superconductor Bi2Sr2Ca2Cu3Ox. (Bi-2223) compound embedded in an Ag matrix requires the knowledge of critical current as a function of mechanical properties. Commercial tapes available in different types have been developed in industrial production scale in which a combination of small diameter filaments, long tape lengths and a ductile matrix results in a conductor with low crack formation and good tolerance against strain. The measurement of critical current and the evaluation of n-index from V-I characteristic curves of Bi-2223/Ag composite tapes subjected to an initial bending strain as a function of number of thermal cycles were done for two types of Bi-2223/Ag composite tapes: with and without steel tape reinforcement. The results showed that tapes with reinforcement presented small critical current degradation as a function of the number of thermal cycles whereas tapes without reinforcement exhibited steadily critical current degradation caused by the propagation of cracks. The n-index followed the same critical current behavior.
Resumo:
Background: The use of botulinum toxin A (BT-A) for the treatment of lower limb spasticity is common in children with cerebral palsy (CP). Following the administration of BT-A, physical therapy plays a fundamental role in potentiating the functionality of the child. The balance deficit found in children with CP is mainly caused by muscle imbalance (spastic agonist and weak antagonist). Neuromuscular electrical stimulation (NMES) is a promising therapeutic modality for muscle strengthening in this population. The aim of the present study is to describe a protocol for a study aimed at analyzing the effects of NMES on dorsiflexors combined with physical therapy on static and functional balance in children with CP submitted to BT-A.Methods/Design: Protocol for a prospective, randomized, controlled trial with a blinded evaluator. Eligible participants will be children with cerebral palsy (Levels I, II and III of the Gross Motor Function Classification System) between five and 12 years of age, with independent gait with or without a gait-assistance device. All participants will receive BT-A in the lower limbs (triceps surae). The children will then be randomly allocated for either treatment with motor physical therapy combined with NMES on the tibialis anterior or motor physical therapy alone. The participants will be evaluated on three occasions: 1) one week prior to the administration of BT-A; 2) one week after the administration of BT-A; and 3) four months after the administration of BT-A (end of intervention). Spasticity will be assessed by the Modified Ashworth Scale and Modified Tardieu Scale. Static balance will be assessed using the Medicapteurs Fusyo pressure platform and functional balance will be assessed using the Berg Balance Scale.Discussion: The aim of this protocol study is to describe the methodology of a randomized, controlled, clinical trial comparing the effect of motor physical therapy combined with NMES on the tibialis anterior muscle or motor physical therapy alone on static and functional balance in children with CP submitted to BT-A in the lower limbs. This study describes the background, hypotheses, methodology of the procedures and measurement of the results.
Resumo:
Using the Cornwall-Jackiw-Tomboulis effective potential for composite operators we compute the QCD vacuum energy as a function of the dynamical quark and gluon propagators, which are related to their respective condensâtes as predicted by the operator product expansion. The identification of this result to the vacuum energy obtained from the trace of the energy-momentum tensor allows us to study the gluon self-energy, verifying that it is fairly represented in the ultraviolet by the asymptotic behavior predicted by the operator product expansion, and in the infrared it is frozen at its asymptotic value at one scale of the order of the dynamical gluon mass. We also discuss the implications of this identity for heavy and light quarks. For heavy quarks we recover, through the vacuum energy calculation, the relation nij{filif)-îi(asl'n)GlivGllv obtained many years ago with QCD sum rules. ©2000 The American Physical Society.
Resumo:
The leading-twist valence-quark distribution function in the pion is obtained at a low normalization scale of an order of the inverse average size of an instanton pc. The momentum dependent quark mass and the quark-pion vertex are constructed in the framework of the instanton liquid model, using a gauge invariant approach. The parameters of instanton vacuum, the effective instanton radius and quark mass, are related to the vacuum expectation values of the lowest dimension quark-gluon operators and to the pion low energy observables. An analytic expression for the quark distribution function in the pion for a general vertex function is derived. The results are QCD evolved to higher momentum-transfer values, and reasonable agreement with phenomenological analyses of the data on parton distributions for the pion is found. ©2000 The American Physical Society.
Resumo:
Background: A scale validated in one language is not automatically valid in another language or culture. The purpose of this study was to validate the English version of the UNESP-Botucatu multidimensional composite pain scale (MCPS) to assess postoperative pain in cats. The English version was developed using translation, back-translation, and review by individuals with expertise in feline pain management. In sequence, validity and reliability tests were performed.Results: Of the three domains identified by factor analysis, the internal consistency was excellent for 'pain expression' and 'psychomotor change' (0.86 and 0.87) but not for 'physiological variables' (0.28). Relevant changes in pain scores at clinically distinct time points (e.g., post-surgery, post-analgesic therapy), confirmed the construct validity and responsiveness (Wilcoxon test, p < 0.001). Favorable correlation with the IVAS scores (p < 0.001) and moderate to very good agreement between blinded observers and 'gold standard' evaluations, supported criterion validity. The cut-off point for rescue analgesia was > 7 (range 0-30 points) with 96.5% sensitivity and 99.5% specificity.Conclusions: The English version of the UNESP-Botucatu-MCPS is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy, when used by anesthesiologists or anesthesia technicians. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy. © 2013 Brondani et al.; licensee BioMed Central Ltd.
Resumo:
Assuming that the 125 GeV particle observed at the LHC is a composite scalar and responsible for the electroweak gauge symmetry breaking, we consider the possibility that the bound state is generated by a non-Abelian gauge theory with dynamically generated gauge boson masses and a specific chiral symmetry breaking dynamics motivated by confinement. The scalar mass is computed with the use of the Bethe-Salpeter equation and its normalization condition as a function of the SU(N) group and the respective fermionic representation. If the fermions that form the composite state are in the fundamental representation of the SU(N) group, we can generate such a light boson only for one specific number of fermions for each group. We address the uncertainties underlying this result, when considering the strong dynamics in isolation. © 2013 American Physical Society.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present study was carried out to evaluate the effect of statins associated with physical exercise (PE) in liver cells in dyslipidemic rats through cariometry. The animals were divided into six groups: animals subjected to a hypercholesterolemic diet (HD), simvastatin, with (G1) and without (G2) physical exercise (PE); HD submitted (G3) or not (G4) to PE, and commercial food diet (F) with (G5) and without (G6) PE. Histological analysis of the liver was performed by staining the slides with hematoxylin and eosin. The cariometric study included measuring the major and minor diameters of the hepatocytes nuclei. The Shapiro-Wilk test was also performed. To determine the differences among the groups, the Kruskal-Wallis Test with Dunn's post-test were conducted. The significance level was set at 5%. No difference was found in the hepatocytes nuclei between G5 and G6. When these groups were related with G3 and G4, reduced nuclei were observed. There was no difference between G1 and G6. The comparison between G6 and G2 showed that the nuclei in G2 were smaller. No difference was detected between G5 and G1. Changes were observed in the nuclei shape in G2 in comparison to G1. Considering G2 and G3, a decrease in the size of nuclei was observed in G3. On the other hand, G2 showed changes in shape in the comparative analysis with G4. The size and shape of G1 nuclei were larger than G3 as well as changes in shape were observed when compared to G4. G4 showed smaller nuclei than G3. Therefore, F, associated or not with the practice of PE, does not alter the size and shape of the hepatocytes nuclei; HD combined with sedentarism influences changes in the morphometric parameters of hepatocytes; and the association of simvastatin and PE seems to protect the hepatocytes nuclei with regard to HD.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)