964 resultados para Cavity ring-down laser spectroscopy using L1102-i Picarro water isotope analyser
Resumo:
In this work results of two radon daughters survey in Brazil are presented and discussed. Some methodological problems concerning the first survey are pointed out which were corrected for the second survey in order to make a realistic long-term measurement of radon decay products in the air. The technique employed in both surveys was the alpha-spectroscopy using CR-39. The reliability of this technique as well as the results of the second survey are discussed, which indicate a poor correlation between radon and its decay products in the air at the researched dwellings. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Through the optical pump technique we have reinvestigated the CHD2OH molecule as a source of far-infrared (FIR) laser lines using for the first time a CO2 laser lasing on regular, hot, and sequence bands. As a consequence, we present here spectroscopic data of 16 now FIR laser transitions from this molecule. Furthermore, we also present a catalogue of all FIR laser lines generated from CHD2OH.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Therapeutic approaches to chronic actinic cheilitis focus on the removal or destruction of diseased epithelium. The CO(2) laser has become an important therapeutic alternative, achieving clinical resolution in around 90% of patients. Although many laser physical parameters have been reported, some are known for their low potential for scar induction without compromising the success of the results. The aim of this clinicohistological study was to compare the therapeutic responses to two low-morbidity protocols involving a single laser pass. A total of 40 patients with chronic multicentric and microscopically proven disease were randomly submitted to two conservative CO(2) laser protocols using a bilateral comparative model. The degree of histological atypia of the epithelium was determined in 26 patients both pre- and postoperatively for both protocols. Other histological phenomena were assessed in addition to this central analysis parameter. Clinical recurrence occurred in 12.5% of patients for each protocol, together with a significant reduction in the degree of epithelial atypia (p < 0.001), which was occasionally complete. However, no difference was found between the protocols (p > 0.05). Using these morphological parameters it was not possible to determine whether postoperative epithelial atypias in part of the sample were reactive or residual in nature. A few patients may show minor postoperative lesions. Due to their potential to achieve clinical and importantly microscopic resolution, the studied protocols may be used for mild through moderate dysplastic epithelium and clinically diffuse disease.
Resumo:
Objective: To investigate the healing of bone defects in male rats treated with salmon calcitonin, low-level laser therapy (LLLT), or both. Background: Healing of bone defects still represents a challenge to health professionals in several areas. In this article, the effect of calcitonin in combination with LLLT on bone repair was studied. Densitometry was used as a valuable tool for the measurement of bone regeneration. Methods: Sixty male Wistar rats underwent bilateral castration surgery before the creation of a surgical bone defect. The animals were randomly divided into four groups: control, treated with calcitonin (Ca), treated with LLLT (La), and treated with calcitonin and LLLT (CaLa). Groups Ca and CaLa received 2 IU/kg of synthetic salmon calcitonin intra-muscularly three times a week. Groups La and CaLa received laser therapy using a gallium-aluminum-arsenide laser (10mW, 20 J/cm(2), wavelength 830 nm). Control animals were submitted to sham irradiation. The animals were sacrificed 7, 14, and 21 days after surgery, and bone defects were analyzed using densitometry. Results: The CaLa group had a higher degree of bone regeneration 14 and 21 days after surgery. Conclusions: The La and CaLa had significantly higher bone mineral density than the control and Ca groups.
Resumo:
The behaviour of hydrophobically modified poly(allylammonium) chloride having octyl, decyl, dodecyl and hexadecyl side chains has been studied in aqueous solution using fluorescence emission techniques. Micropolarity studies using the I-1/I-3 ratio of the vibronic bands of pyrene show that the formation of hydrophobic microdomains depends on both the length of the side chain and the polymer concentration. The I-1/I-3 ratio of the polymers with low hydrophobe content (less than 5% mel) changes substantially when reaching a certain concentration. These changes are assigned to aggregation originating from interchain interactions. This behaviour is also confirmed by the behaviour of the monomer/excimer emission intensities of pyrene- dodecanoic acid used as a probe. For polymers having dodecyl side chains and hydrophobe contents higher than 10%, aggregates are formed independently of the polymer concentration. Anisotropy measurements show that microdomains resulting from the inter- and/or intramolecular interactions are similar to those observed for cationic surfactants. Viscosity measurements show that the coil dimensions are substantially decreased for the polymers having high hydrophobe contents, indicating intramolecular associations.
Resumo:
A histological study on the healing of extraction wounds following laser irradiation using a He-Ne laser, was carried out in rats. The results suggest that this mode of treatment has a beneficial effect on initial bony wound healing. Proliferation of fibroblasts and formation of trabecular osteoid tissue were found to be more prominent within the irradiated group. The deposition of led in the newly formed bone suggests swifter ossification within the irradiated group.
Resumo:
The aim of this study was to assess the skeletal age of Brazilian individuals with Down syndrome (DS) using the method of Greulich and Pyle. Forty subjects with DS between the ages of 6 and 16 years were studied and compared to a control sample of children without DS. The statistical analysis showed that at the age of 7 years the skeletal age (SA) of the individuals with DS was delayed in relation to their chronological age (CA) (SA < CA). On the other hand, at the age of 15 years, their SA was advanced in relation to their CA (SA > CA). An evaluation of the results suggests that the period of adolescent development for individuals with DS was shorter. These individuals reach the completion of bone maturation earlier compared to individuals without DS. © 2008 Special Care Dentistry Association and Wiley Periodicals, Inc.
Resumo:
The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
To determinate the multielemental concentrations in biological samples using the technique of total reflection X-ray fluorescence (TRFX) is essential the use of standard samples. The aim of this study is the determination of the sensitivities of the relevant elements in standard samples (Multi Element atomic spectroscopy standard solution in HNO3 I) prepared in three solutions with different and known concentrations. Based on the sensitivities of the elements contained in the multilelementar standard sample, it can estimate the sensitivity for an element found in the biological sample and consequently it is possible to determinate the concentration, even though the standard does not contain this element. The measurement of fluorescence was performed at the Brazilian Synchrotron Light Laboratory (LNLS) in Campinas
Resumo:
The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.
Resumo:
Objectives: Considering the enamel chemical structure, especially carbonate band, which has a major role in the caries prevention, the objective of the present study was to assess the chemical alterations on the enamel irradiated with CO2 laser by means of FTIR spectroscopy and SEM analysis. Design: The enamel surfaces were analysed on a spectrometer for acquisition of the absorption spectrum relative to the chemical composition of the control sample. The irradiation was conducted with a 10.6-mu m CO2 laser (0.55 W, 660 W/cm(2)). The carbonate absorption band at 1600-1291 cm(-1) as well as the water absorption band at 3793-2652 cm(-1) was measured in each sample after the irradiation. The water band was measured again 24-h after the irradiation. The band area of each chemical compound was delimited, the background was subtracted, and the area under each band was integrated. Each area was normalized by the phosphate band (1190-702 cm(-1)). Results: There was a statistically significant decrease (p < 0.05) in the water content after irradiation (control: 0.184 +/- 0.04; irradiated: 0.078 +/- 0.026), which increased again after rehydration (0.145 +/- 0.038). The carbonate/phosphate ratio was measured initially (0.112 +/- 0.029) and its reduction after irradiation indicated the carbonate loss (0.088 +/- 0.014) (p < 0.05). Conclusion: The 10.6-mu m CO2 laser irradiation diminishes the carbonate and water contents in the enamel after irradiation. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
La valutazione progressiva e il monitoraggio di una ferita difficile impongono misurazioni periodiche per valutare in modo qualitativo e quantitativo l'esistenza e l'entita della riepitelizzazione in rapporto alle pratiche terapeutiche effettuate. L'entità della guarigione nei primi 1530 giorni di trattamento, intesa come riduzione di area percentuale, nelle lesioni ulcerative di origine venosa permette secondo alcuni autori della letteratura scientifica, di avere delle informazioni prognostiche di guarigione completa a sei mesi. Altri autori invece mostrano casistiche analoghe indicando come nelle ulcere venose non si possa predire con facilità la guarigione a sei mesi.Le metodiche di misurazione delle ferite possono essere suddivise in bidimensionali e tridimensionali: nel primo gruppo troviamo la misurazione semplice, le metodiche di tracciamento, planimetria, analisi fotografica analogica e digitale. Queste metodiche misurano i diametri, il perimetro e l'area delle ferite. Nel secondo gruppo si collocano l'uso di righello Kundin, le metodiche di riempimento con alginato o con soluzione fisiologica, le metodiche stereofotogrammetriche e l'uso di strumenti laser. Queste metodiche permettono di calcolare con varie approssimazioni anche il volume delle ferite studiate. La tesi ha preso in esame un gruppo di 17 pazienti affetti da ulcere venose croniche effettuando misurazioni con lo strumento più accurato e preciso disponibile (minolta Vivid 900 laser + sensore) e acquisendo i dati con il software Derma. I pazienti sono stati misurati al primo accesso in ambulatorio, dopo 15 giorni e dopo sei mesi. Sono stati acquisiti i dati di area, perimetro, volume, profondità e guarigione a 6 mesi. L'analisi statistica condotta con modalità non parametriche di analisi dei ranghi non ha associato nessuno di questi valori ne' valori derivati ( delta V /delta A; Delta V/ Delta P) alla guarigione a 6 mesi. Secondo le analisi da noi effettuate, sebbene con l'incertezza derivata da un gruppo ridotto di pazienti, la guarigione delle lesioni ulcerative venose non è predicibile a 6 mesi utilizzando sistemi di misurazione di dimensioni, area e volume.