814 resultados para COMPUTER ALGEBRA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tarea (A):(...) Trataremos de extender a Sp(n,1) los resultados conseguidos sobre la imagen del homomorfismo de Lepowsky cuando G es SO(n,1) ó SU(n,1). (...) Tarea (B): (...) Para todo grupo de Lie de rango uno, con rango (G) = rango (K), los elementos del álgebra B son W-invariantes y que este resultado ya ha sido establecido para los grupos SO(2n,1) y SU(n,1); durante el período correspondiente a este subsidio esperamos extender este resultado a todo grupo de Lie de rango uno con rango (G) = rango (K). Tarea (C): Durante este período esperamos también avanzar en la determinación del dual unitario del grupo Spin (2n,C).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a study of a state of the art implementation of a new computer integrated testing (CIT) facility within a company that designs and manufactures transport refrigeration systems. The aim was to use state of the art hardware, software and planning procedures in the design and implementation of three CIT systems. Typical CIT system components include data acquisition (DAQ) equipment, application and analysis software, communication devices, computer-based instrumentation and computer technology. It is shown that the introduction of computer technology into the area of testing can have a major effect on such issues as efficiency, flexibility, data accuracy, test quality, data integrity and much more. Findings reaffirm how the overall area of computer integration continues to benefit any organisation, but with more recent advances in computer technology, communication methods and software capabilities, less expensive more sophisticated test solutions are now possible. This allows more organisations to benefit from the many advantages associated with CIT. Examples of computer integration test set-ups and the benefits associated with computer integration have been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supportive presentation, computer games, non-photorealistic rendering camera control, camera AI, human factors, user interfaces, action summary, action replay, non-photorealistic rendering case studies, psychology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stipping, non-photorealistic rendering, non-photorealistic computer graphics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Illustration Watermarks, Image annotation, Virtual data exploration, Interaction techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We characterize the values of the stable rank for Leavitt path algebras, by giving concrete criteria in terms of properties of the underlying graph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.