999 resultados para Breast CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CDC25 phosphatases control cell cycle progression by activating cyclin dependent kinases. The three CDC25 isoforms encoding genes are submitted to alternative splicing events which generate at least two variants for CDC25A and five for both CDC25B and CDC25C. An over-expression of CDC25 was reported in several types of cancer, including breast cancer, and is often associated with a poor prognosis. Nevertheless, most of the previous studies did not address the expression of CDC25 splice variants. Here, we evaluated CDC25 spliced transcripts expression in anti-cancerous drug-sensitive and resistant breast cancer cell lines in order to identify potential breast cancer biomarkers. Methods: CDC25 splice variants mRNA levels were evaluated by semi-quantitative RT-PCR and by an original real-time RT-PCR assay. Results: CDC25 spliced transcripts are differentially expres-sed in the breast cancer cell lines studied. An up-regulation of CDC25A2 variant and an increase of the CDC25C5/C1 ratio are associated to the multidrug-resistance in VCREMS and DOXOR breast cancer cells, compared to their sensitive counterpart cell line MCF-7. Additionally, CDC25B2 tran-script is exclusively over-expressed in VCREMS resistant cells and could therefore be involved in the development of certain type of drug resistance. Conclusions: CDC25 splice variants could represent interesting potential breast cancer prognostic biomarkers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is now widely recognized that translation factors are involved in cancer development and that components of the translation machinery that are deregulated in cancer cells may become targets for cancer therapy. The eukaryotic Release Factor 3 (eRF3) is a GTPase that associates with eRF1 in a complex that mediates translation termination. eRF3a/GSPT1 first exon contains a (GGC)n expansion coding for proteins with different N-terminal extremities. Herein we show that the longer allele (12-GGC) is present in 5.1% (7/137) of the breast cancer patients analysed and is absent in the control population (0/135), corresponding to an increased risk for cancer development, as revealed by Odds Ratio analysis. mRNA quantification suggests that patients with the 12-GGC allele overexpress eRF3a/GSPT1 in tumor tissues relative to the normal adjacent tissues. However, using an in vivo assay for translation termination in HEK293 cells, we do not detect any difference in the activity of the eRF3a proteins encoded by the various eRF3a/GSPT1 alleles. Although the connection between the presence of eRF3a/GSPT1 12-GGC allele and tumorigenesis is still unknown, our data suggest that the presence of the 12-GGC allele provides a potential novel risk marker for various types of cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The histone deacetylase inhibitors sodium butyrate (NaBu) and trichostatin A (TSA) exhibit anti-proliferative activity by causing cell cycle arrest and apoptosis. The mechanisms by which NaBu and TSA cause apoptosis and cell cycle arrest are not yet completely clarified, although these agents are known to modulate the expression of several genes including cell-cycle- and apoptosis-related genes. The enzymes involved in the process of translation have important roles in controlling cell growth and apoptosis, and several of these translation factors have been described as having a causal role in the development of cancer. The expression patterns of the translation mechanism, namely of the elongation factors eEF1A1 and eEF1A2, and of the termination factors eRF1 and eRF3, were studied in the breast cancer cell line MCF-7 by real-time quantitative reverse transcription-polymerase chain reaction after a 24-h treatment with NaBu and TSA. NaBu induced inhibition of translation factors' transcription, whereas TSA caused an increase in mRNA levels. Thus, these two agents may modulate the expression of translation factors through different pathways. We propose that the inhibition caused by NaBu may, in part, be responsible for the cell cycle arrest and apoptosis induced by this agent in MCF-7 cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: An asynchronous eLearning system was developed for radiographers in order to promote a better knowledge about senology and mammography. Objectives: to assess the learners’ satisfaction. Methods: Target population included radiographers and radiogr aphy students, in order to assess eLearning satisfaction according to different experience levels in breast imaging. Satisfaction was measured through a questionnaire developed especially for eLearning systems, using a seven - point Likert scale. Main topics related are content, interface, personalization and learning community. Results: Overall, 85% of learners were satisfied with the course and 87,5% considered that the course is successful. Main areas that were evaluated by most learners in a positive way were interface and content (between six and seven - point); on the other hand, learning community presented a wider distribution of answers . Conclusions: The course provides an overall high degree of learner satisfaction, thus providing more effective knowle dge gain on breast imaging for radiographers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The calculation of the dose is one of the key steps in radiotherapy planning1-5. This calculation should be as accurate as possible, and over the years it became feasible through the implementation of new algorithms to calculate the dose on the treatment planning systems applied in radiotherapy. When a breast tumour is irradiated, it is fundamental a precise dose distribution to ensure the planning target volume (PTV) coverage and prevent skin complications. Some investigations, using breast cases, showed that the pencil beam convolution algorithm (PBC) overestimates the dose in the PTV and in the proximal region of the ipsilateral lung. However, underestimates the dose in the distal region of the ipsilateral lung, when compared with analytical anisotropic algorithm (AAA). With this study we aim to compare the performance in breast tumors of the PBC and AAA algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Evaluate the type of breast compression (gradual or no gradual) that provides less discomfort to the patient. Methods and Materials: The standard projections were simulated [craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast compressions in 90 volunteers women aged between 19 and 86. The women were organised in groups according to the breast density. The intensity of discomfort was evaluated using the scale that have represented several faces (0-10) proposed by Wong Baker in the end of each simulation. It was also applied an interview using focus group to debate the score that were attributed during pain evaluation and to identify the criteria that were considered to do the classification. Results: The women aged between 19-29y (with higher breast density) classified the pain during no gradual compression as 4 and the gradual compression as 2 for both projections. The MLO projection was considered the most uncomfortable. During the focus group interview applied to this group was highlighted that compression did not promoted pain but discomfort. They considered that the high expectations of pain did not correspond to the discomfort that they felt. Similar results were identified for the older women (30-50y; > 50y). Conclusion: The radiographers should considerer the technique for breast compression. The gradual compression was considered for the majority of the women as the most comfortable regardless of breast density. The MLO projection was considered as uncomfortable due to the positioning (axila and inclusion of pectoral muscle) and due to the higher breast compression compared to the CC projection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze cervical and breast cancer mortality in Brazil according to socioeconomic and welfare indicators. METHODS Data on breast and cervical cancer mortality covering a 30-year period (1980-2010) were analyzed. The data were obtained from the National Mortality Database, population data from the Brazilian Institute of Geography and Statistics database, and socioeconomic and welfare information from the Institute of Applied Economic Research. Moving averages were calculated, disaggregated by capital city and municipality. The annual percent change in mortality rates was estimated by segmented linear regression using the joinpoint method. Pearson’s correlation coefficients were conducted between average mortality rate at the end of the three-year period and selected indicators in the state capital and each Brazilian state. RESULTS There was a decline in cervical cancer mortality rates throughout the period studied, except in municipalities outside of the capitals in the North and Northeast. There was a decrease in breast cancer mortality in the capitals from the end of the 1990s onwards. Favorable socioeconomic indicators were inversely correlated with cervical cancer mortality. A strong direct correlation was found with favorable indicators and an inverse correlation with fertility rate and breast cancer mortality in inner cities. CONCLUSIONS There is an ongoing dynamic process of increased risk of cervical and breast cancer and attenuation of mortality because of increased, albeit unequal, access to and provision of screening, diagnosis and treatment. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.